Monthly use of a real-time continuous glucose monitoring system as an educational and motivational tool for poorly controlled type 1 diabetes adolescents

被引:9
|
作者
Glowinska-Olszewska, B. [1 ]
Tobiaszewska, M. [1 ]
Luczynski, W. [1 ]
Bossowski, A. [1 ]
机构
[1] Med Univ Bialystok, Dept Paediat, Div Cardiol, PL-15274 Bialystok, Poland
来源
ADVANCES IN MEDICAL SCIENCES | 2013年 / 58卷 / 02期
关键词
diabetes type 1; adolescents; real-time continuous glucose monitoring; metabolic control; education; IMPROVED GLYCEMIC CONTROL; SENSOR-AUGMENTED PUMP; PEDIATRIC-PATIENTS; PROLONGED USE; CHILDREN; THERAPY; HYPOGLYCEMIA; VARIABILITY; LIFE;
D O I
10.2478/ams-2013-0024
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Purpose: Experience with the use of real-time continuous glucose monitoring systems (RT-CGMS) in teenagers with type 1 diabetes mellitus (T1DM) is limited. We aimed to assess the possibility of glycaemic control improvement and to characterize the group of adolescents, who may gain long-term benefits from the use of the RT-CGMS. Methods: Forty T1DM patients, aged 14.6 +/- 2.1 years, with diabetes duration 7.4 +/- 3.6 years and initial HbA(1)c 9.3 +/- 1.5% were recruited. The analysis was based on one-month glucose sensors use, combined with the thorough family support. Patients were analysed in groups according to baseline HbA(1)c: below and above 7.5%, and 10.0%. Comparison between patients with or without improvement in HbA(1)c after 3-month follow-up was also performed. Patients' satisfaction based on the questionnaire was assessed. Results: HbA(1)c level in entire study group decreased after three months, from 9.3 +/- 1.0% to 8.8 +/- 1.6% (P<0.001). In the group with HbA(1)c improvement, reduction was the highest: 9.0 +/- 1.3% vs. 8.0 +/- 1.2% (P<0.001). Only the group with initial HbA(1)c>10% did not achieve significant improvement: 11.2 +/- 0.5% vs. 10.9 +/- 1.1 (P=0.06). In satisfaction questionnaire the lowest scores (negative opinion) were reported by group of patients with initial HbA(1)c above 10%, while the highest scores (positive opinion) were found in the group with improvement of HbA(1)c after 3 month follow-up. Conclusion: Short-term use of CGMS RT, united with satisfaction questionnaire, performed in poorly controlled teenagers with T1DM, can be useful in defining the group of young patients, who can benefit from long-term CGMS RT use in metabolic control improvement.
引用
收藏
页码:344 / 352
页数:9
相关论文
共 50 条
  • [1] Use of a real time continuous glucose monitoring system as a motivational device for poorly controlled type 2 diabetes
    Yoo, H. J.
    An, H. G.
    Park, S. Y.
    Ryu, O. H.
    Kim, H. Y.
    Seo, J. A.
    Hong, E. G.
    Shin, D. H.
    Kim, Y. H.
    Kim, S. G.
    Choi, K. M.
    Park, I. B.
    Yu, J. M.
    Baik, S. H.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2008, 82 (01) : 73 - 79
  • [2] Effectiveness of Real-Time, Remote Continuous Glucose Monitoring in Adolescents with Poorly Controlled Type 1 Diabetes
    Choudhari, Pooja
    Marwa, Albara
    White, Perrin C.
    Choudhary, Abha
    DIABETES, 2024, 73
  • [3] Use of real time continuous glucose monitoring system as a motivational device for type 2 diabetes
    Yoo, Hye Jin
    Kim, Hae Sook
    Yang, Sae Jeong
    Park, Ju Ri
    Kim, Tae Nyun
    Lee, Yun Jeong
    Park, Soo Yeon
    Kim, Hee Young
    Lee, Kye Won
    Seo, Ji A.
    Shin, Dong Hyun
    Kim, Sin Gon
    Kim, Nan Hee
    Choi, Kyung Mook
    Choi, Dong Seop
    Baik, Sei Hyun
    DIABETES, 2008, 57 : A555 - A555
  • [4] Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes
    Eman Alfadhli
    Eman Osman
    Taghreed Basri
    Diabetology & Metabolic Syndrome, 8
  • [5] Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes
    Alfadhli, Eman
    Osman, Eman
    Basri, Taghreed
    DIABETOLOGY & METABOLIC SYNDROME, 2016, 8
  • [6] Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring
    Deis, Dorothee
    Bolinder, Jan
    Riveline, Jean-Pierre
    Battelino, Tadej
    Bosi, Emanuele
    Tubiana-Rufi, Nadia
    Kerr, David
    Phillip, Moshe
    DIABETES CARE, 2006, 29 (12) : 2730 - 2732
  • [7] Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
    Jackson, Melanie A.
    Ahmann, Andrew
    Shah, Viral N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : S27 - S34
  • [8] Impact of real-time continuous glucose monitoring system usage on endothelial function in adolescents with type 1 diabetes
    Glowinska-Olszewska, B.
    Jamiolkowksa, M.
    Jamiolkowska, I.
    Luczynski, W.
    Tolwinska, J.
    Bossowski, A.
    DIABETOLOGIA, 2014, 57 : S90 - S90
  • [9] Effectiveness of continuous glucose monitoring in children, adolescents, and young adults with poorly controlled type 1 diabetes
    Lewis, Kevin R.
    McCrone, Susan
    Deiriggi, Pamela
    Bendre, Sachin
    JOURNAL FOR SPECIALISTS IN PEDIATRIC NURSING, 2017, 22 (01)
  • [10] Effectiveness of Continuous Glucose Monitoring in Children, Adolescents, and Young Adults with Poorly Controlled Type 1 Diabetes
    Lewis, Kevin
    Mccrone, Susan
    Bendre, Sachin
    Deiriggi, Pamela
    Dye, Amanda
    DIABETES, 2014, 63 : A218 - A218