Gamma/X-ray linear pushbroom stereo for 3D cargo inspection

被引:0
|
作者
Zhu, Zhigang [1 ,2 ]
Hu, Yu-Chi [2 ,3 ]
机构
[1] CUNY City Coll, Dept Comp Sci, New York, NY 10031 USA
[2] CUNY, Grad Ctr, Dept Comp Sci, New York, NY 10016 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
来源
关键词
pushbroom imaging; automatic 3D measurements; cargo inspection; homeland security;
D O I
10.1117/12.664204
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For evaluating the contents of trucks, containers, cargo, and passenger vehicles by a non-intrusive gamma-ray or X-ray imaging system to determine the possible presence of contraband, three-dimensional (3D) measurements could provide more information than 2D measurements. In this paper, a linear pushbroom scanning model is built for such a commonly used gamma-ray or x-ray cargo inspection system. Accurate 3D measurements of the objects inside a cargo can be obtained by using two such scanning systems with different scanning angles to construct a pushbroom stereo system. A simple but robust calibration method is proposed to find the important parameters of the linear pushbroom sensors. Then, a fast and automated stereo matching algorithm based on free-form deformable registration is developed to obtain 3D measurements of the objects under inspection. A user interface is designed for 3D visualization of the objects in interests. Experimental results of sensor calibration, stereo matching, 3D measurements and visualization of a 3D cargo container and the objects inside, are presented.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Tackling the X-ray cargo inspection challenge using machine learning
    Jaccard, Nicolas
    Rogers, Thomas W.
    Morton, Edward J.
    Griffin, Lewis D.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX), 2016, 9847
  • [22] Relocatable cargo X-ray inspection systems utilizing compact linacs
    Sapp, WW
    Mishin, AV
    Adams, WL
    Callerame, J
    Grodzins, L
    Rothschild, PJ
    Schueller, R
    Smith, GJ
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2001, 576 : 1057 - 1060
  • [23] Linatron Mi6, the X-Ray Source for Cargo Inspection
    Chen, Gongyin
    Turner, John
    Nisius, David
    Holt, Kevin
    Brooks, Alan
    23rd International Conference on the Application of Accelerators in Research and Industry - CAARI 2014, 2015, 66 : 68 - 74
  • [24] 3D X-RAY IMAGE COMPOSITION
    Armeanu, Constantin Catalin
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2016, 78 (01): : 309 - 320
  • [25] Multiscale 3D X-ray imaging
    R. Joseph Kline
    Nature Electronics, 2019, 2 : 435 - 436
  • [26] X-ray holography: Atoms in 3D
    Tegze, M.
    Faigel, G.
    Bortel, G.
    Marchesini, S.
    Belakhovsky, M.
    Simionovici, A.
    Journal of Alloys and Compounds, 2005, 401 (1-2): : 92 - 98
  • [27] 3D discrete X-ray transform
    Averbuch, A
    Shkolnisky, Y
    APPLIED AND COMPUTATIONAL HARMONIC ANALYSIS, 2004, 17 (03) : 259 - 276
  • [28] 3D X-ray crystal microscope
    Ice, GE
    Larson, BC
    ADVANCED ENGINEERING MATERIALS, 2000, 2 (10) : 643 - 646
  • [29] X-ray holography: Atoms in 3D
    Tegze, M
    Faigel, G
    Bortel, G
    Marchesini, S
    Belakhovsky, M
    Simionovici, A
    JOURNAL OF ALLOYS AND COMPOUNDS, 2005, 401 (1-2) : 92 - 98
  • [30] Multiscale 3D X-ray imaging
    Kline, R. Joseph
    NATURE ELECTRONICS, 2019, 2 (10) : 435 - 436