Optimum sizing of photovoltaic battery systems incorporating uncertainty through design space approach

被引:140
作者
Arun, P. [1 ]
Banerjee, Rangan [1 ]
Bandyopadhyay, Santanu [1 ]
机构
[1] Indian Inst Technol, Dept Energy Sci & Engn, Bombay 400076, Maharashtra, India
关键词
Photovoltaic-battery system; Optimum system sizing; Chance constrained programming; Sizing curve; Design space; Uncertainty; WATER-HEATING SYSTEMS; LOSS-OF-POWER; SOLAR-RADIATION; ENERGY SYSTEM; OPTIMIZATION; MODEL; PROBABILITY; PARAMETERS;
D O I
10.1016/j.solener.2009.01.003
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Photovoltaic-battery system is an option for decentralized power generation for isolated locations receiving abundant sunshine. A methodology for the optimum sizing of photovoltaic-battery system for remote electrification incorporating the uncertainty associated with solar insolation is proposed in this paper. The proposed methodology is based on the design space approach involving a time series simulation of the entire system. The design space approach was originally proposed for sizing of the system with deterministic resource and demand. In the present paper, chance constrained programming approach has been utilized for incorporating the resource uncertainty in the system sizing and the concept of design space is extended to incorporate resource uncertainty. The set of all feasible design configurations is represented by a sizing curve. The sizing curve for a given confidence level, connects the combinations of the photovoltaic array ratings and the corresponding minimum battery capacities capable of meeting the specified load, plotted on an array rating vs. battery capacity diagram. The methodology is validated using a sequential Monte Carlo simulation approach with illustrative examples. It is shown that for the case of constant coefficient of variation of solar insolation, the set of sizing curves for different confidence levels may be represented by a generalized curve. Selection of optimum system configuration for different reliability levels based on the minimum cost of energy is also presented. The effect of ambient temperature on sizing a stand-alone photovoltaic-battery system is also illustrated through a representative example. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1013 / 1025
页数:13
相关论文
共 32 条
[1]  
[Anonymous], 1997, SOLAR ENERGY PRINCIP
[2]   Optimum sizing of battery-integrated diesel generator for remote electrification through design-space approach [J].
Arun, P. ;
Banerjee, Rangan ;
Bandyopadhyay, Santanu .
ENERGY, 2008, 33 (07) :1155-1168
[3]  
Arun P., 2007, Energy for Sustainable Development, VXI, P21, DOI DOI 10.1016/S0973-0826(08)60406-8
[4]   New measures and procedures to manage financial risk with applications to the planning of gas commercialization in Asia [J].
Aseeri, A ;
Bagajewicz, MJ .
COMPUTERS & CHEMICAL ENGINEERING, 2004, 28 (12) :2791-2821
[5]   Optimised model for community-based hybrid energy system [J].
Ashok, S. .
RENEWABLE ENERGY, 2007, 32 (07) :1155-1164
[6]   A chance-constrained multi-period model for a special multi-reservoir system [J].
Azaiez, MN ;
Hariga, M ;
Al-Harkan, I .
COMPUTERS & OPERATIONS RESEARCH, 2005, 32 (05) :1337-1351
[7]   Sizing of a stand-alone hybrid wind-photovoltaic system using a three-event probability density approximation [J].
Bagul, AD ;
Salameh, ZM ;
Borowy, B .
SOLAR ENERGY, 1996, 56 (04) :323-335
[8]   AN ANALYTICAL METHOD TO DETERMINE THE OPTIMAL SIZE OF A PHOTOVOLTAIC PLANT [J].
BARRA, L ;
CATALANOTTI, S ;
FONTANA, F ;
LAVORANTE, F .
SOLAR ENERGY, 1984, 33 (06) :509-514
[9]   THE DESIGN OF PHOTOVOLTAIC PLANTS - AN OPTIMIZATION PROCEDURE [J].
BARTOLI, B ;
CUOMO, V ;
FONTANA, F ;
SERIO, C ;
SILVESTRINI, V .
APPLIED ENERGY, 1984, 18 (01) :37-47
[10]   Sizing of a stand-alone photovoltaic power system at Dhaka [J].
Bhuiyan, MMH ;
Asgar, MA .
RENEWABLE ENERGY, 2003, 28 (06) :929-938