Usefulness of the external jugular vein examination in detecting abnormal central venous pressure in critically ill patients

被引:48
|
作者
Vinayak, Ajeet G.
Levitt, Joseph
Gehlbach, Brian
Pohlman, Anne S.
Hall, Jesse B.
Kress, John P.
机构
[1] Univ Chicago, Dept Med, Pulm & Crit Care Med Sect, Chicago, IL 60637 USA
[2] Univ Virginia, Div Pulm & Crit Care Med, Dept Internal Med, Charlottesville, VA USA
[3] Stanford Univ, Dept Med, Div Pulm & Crit Care Med, Stanford, CA 94305 USA
关键词
D O I
10.1001/archinte.166.19.2132
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Central venous pressure (CVP) provides important information for the management of critically ill patients. The external jugular vein (EJV) is easier to visualize than the internal jugular vein and may give a reliable estimate of CVP. Methods: To determine the usefulness of the EJV examination in detecting abnormal CVP values, we performed a prospective blinded evaluation comparing it with CVP measured using an indwelling catheter in critically ill patients with central venous catheters. Blinded EJV examinations were performed by clinicians with 3 experience levels (attending physicians, residents and fellows, and interns and fourth-year medical students) to estimate CVP (categorized as low [<= 5 cm of water] or high [>= 10 cm of water]). The usefulness of the EJV examination in discriminating low vs high CVP was measured using receiver operating characteristic curve analysis. Results: One hundred eighteen observations were recorded among 35 patients. The range of CVP values was 2 to 20 cm of water. The EJV was easier to visualize than the internal jugular vein (mean visual analog scale score, 8 vs 5; P <.001). The reliability for determining low and high CVP was excellent, with areas under the curve of 0.95 (95% confidence interval [CI], 0.88-1.00) and 0.97 (95% CI, 0.92-1.00), respectively, for attending physicians and 0.86 (95% CI, 0.78-0.95) and 0.90 (95% CI, 0.84-0.96), respectively, for all examiners. Conclusion: The EJV examination correlates well with catheter-measured CVP and is a reliable means of identifying low and high CVP values.
引用
收藏
页码:2132 / 2137
页数:6
相关论文
共 50 条
  • [31] Usefulness of central venous saturation as a predictor of thiamine deficiency in critically ill patients: a case report
    Numata, Genri
    Kodera, Satoshi
    Kiriyama, Hiroyuki
    Nakayama, Atsuko
    Amiya, Eisuke
    Kiyosue, Arihiro
    Hatano, Masaru
    Takimoto, Eiki
    Watanabe, Masafumi
    Komuro, Issei
    JOURNAL OF INTENSIVE CARE, 2017, 5
  • [32] Usefulness of central venous saturation as a predictor of thiamine deficiency in critically ill patients: A case report
    Numata G.
    Kodera S.
    Kiriyama H.
    Nakayama A.
    Amiya E.
    Kiyosue A.
    Hatano M.
    Takimoto E.
    Watanabe M.
    Komuro I.
    Journal of Intensive Care, 5 (1)
  • [33] Ultrasound Accurately Reflects the Jugular Venous Examination but Underestimates Central Venous Pressure
    Deol, Gur Raj
    Collett, Nicole
    Ashby, Andrew
    Schmidt, Gregory A.
    CHEST, 2011, 139 (01) : 95 - 100
  • [34] Incidence of deep vein thrombosis in critically ill ICU patients with a femoral central venous catheter
    P Myrianthefs
    P Aravosita
    M Georganas
    L Livieratos
    G Baltopoulos
    Critical Care, 8 (Suppl 1):
  • [35] Correlation of sonographic measurements of the internal jugular vein with central venous pressure
    Donahue, Sean P.
    Wood, Joseph P.
    Patel, Bhavesh M.
    Quinn, James V.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2009, 27 (07): : 851 - 855
  • [36] CENTRAL VENOUS-PRESSURE MONITORING FOR THE CRITICALLY ILL IN ZAMBIA
    DEEDAT, AM
    WILSON, IH
    WATTERS, DAK
    TROPICAL DOCTOR, 1990, 20 (02) : 74 - 76
  • [37] Evaluation of the placement and maintenance of central venous jugular catheters in critically ill dogs and cats
    Reminga, Christin L.
    Silverstein, Deborah C.
    Drobatz, Kenneth J.
    Clarke, Dana L.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2018, 28 (03) : 232 - 243
  • [38] Point-Of-Care Ultrasound Of Femoral Vein Diameter Predicts Central Venous Pressure In Mechanically Ventilated Critically Ill Patients
    Cho, R.
    Leatherman, J.
    Williams, D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [39] HYDROMEDIASTINUM FOLLOWING INSERTION OF A CENTRAL VENOUS-PRESSURE LINE VIA THE RIGHT EXTERNAL JUGULAR-VEIN
    LEE, TS
    CHEN, BJ
    JOURNAL OF CLINICAL ANESTHESIA, 1993, 5 (05) : 436 - 438
  • [40] Renal failure in critically ill patients, beware of applying (central venous) pressure on the kidney
    Chen, Xiukai
    Wang, Xiaoting
    Honore, Patrick M.
    Spapen, Herbert D.
    Liu, Dawei
    ANNALS OF INTENSIVE CARE, 2018, 8