Advanced Virtual Monochromatic Images from Dual Source Dual-Energy CT for a Reduction in the Contrast Medium Dose (389 mgI/kg) in Multiphase Liver CT: Evaluation of Image Quality and Focal Lesion Conspicuity

被引:1
|
作者
Kim, Ji Eun [1 ]
Kim, Hyun Ok [2 ,3 ]
Bae, Kyungsoo [1 ]
Cho, Jae Min [1 ]
Choi, Ho Cheol [1 ]
Choi, Dae Seob [1 ]
Na, Jaebeom [1 ]
机构
[1] Gyeongsang Natl Univ, Gyeongsang Natl Univ Hosp, Dept Radiol, Coll Med, Jinju, South Korea
[2] Gyeongsang Natl Univ, Coll Med, Dept Internal Med, 79 Gangnam Ro, Jinju 52727, South Korea
[3] Gyeongsang Natl Univ Hosp, Jinju, South Korea
关键词
Contrast Medium; Computed Tomography; Dual-Energy; Virtual Monochromatic Image; LOW TUBE VOLTAGE; ITERATIVE RECONSTRUCTION ALGORITHM; ABDOMINAL CT; DYNAMIC CT; AGENT; NOISE; SELECTION; PROTOCOL; SIZE; MDCT;
D O I
10.5812/iranjradiol.83014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Low-energy advanced virtual monochromatic images (VMIs) from dual source dual-energy CT(DSCT) could be applied to reduce contrast medium dose due to superior iodine contrast-to-noise ratios (CNRs). Objectives: To investigate feasibility of advanced VMIs from DSCT to reduce contrast medium dose in multiphase liver CT without impairing image quality and conspicuity of focal hepatic lesions (FHLs). Patients and Methods: Ninety-four patients with 110 FHL5 underwent follow-up CT twice prospectively with different protocols: protocol A, conventional 100 kVp and 555 mgI/kg; protocol B, dual-energy mode and 389 mgI/kg. The signal-to-noise ratio (SNR) and lesion-to-liver CNR were compared between the VMIs (40 -120 keV,10-keV interval) reconstructed using advanced image-based algorithm and conventional images. Two radiologists qualitatively evaluated VMIs, compared with the 100 kVp images, using a six-point scale. Results: The SNRs of pancreas, aorta, portal and hepatic vein were similar to those at 100 kVp images (P > 0.05) at 40-50 key images during late arterial phase (LAP) and at 40-60 key images during portal venous phase (PVP) except for the SNRs of aorta and veins at 40 key images which were significantly higher (P < 0.0109) during both phases and PVP, respectively. The CNR of 56 hypervascular FHLs was significantly higher at 40 - 50 keV images (P < 0.0002) and was similar at 60 keV images (P > 0.05) during LAP. The CNR of 58 hypovascular FHLs was similar at 40 -120 key images (P > 0.05) during PVP. Among the VMIs, 50 keV and 50 - 60 keV images received the highest scores (P < 0.0315 and P < 0.0041) by both reviewers during LAP and PVP, respectively. Conclusion: Advanced 50 - 60 keV images from DSCT allowed contrast dose reduction by 30% in multiphase liver CT without impairing image quality and conspicuity of FHL5, compared with the conventional 100 kVp images with 555 mgI/kg.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Quantifying the Material Differentiation Ability of Virtual Monochromatic Images Synthesized From Dual-Energy CT (DECT) Images (Phantom Study)
    Tehrani, J. Nasehi
    Hui, C.
    Libby, B.
    Goode, A.
    Collins, P.
    Siebers, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E167 - E167
  • [32] Single source split filter dual energy: Image quality and liver lesion detection in abdominal CT
    Eichler, Mathis
    May, Matthias
    Wiesmueller, Marco
    Saake, Marc
    Heiss, Rafael
    Uder, Michael
    Wuest, Wolfgang
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126
  • [33] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Hongwei Liang
    Silin Du
    Gaowu Yan
    Yang Zhou
    Tianyu Yang
    Zhiwei Zhang
    Chenyi Luo
    Hongfan Liao
    Yongmei Li
    Abdominal Radiology, 2023, 48 : 2596 - 2603
  • [34] Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: Image quality, radiation dose and diagnostic performance
    Sun, Hao
    Hou, Xin-Yi
    Xue, Hua-Dan
    Li, Xiao-Guang
    Jin, Zheng-Yu
    Qian, Jia-Ming
    Yu, Jian-Chun
    Zhu, Hua-Dong
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (05) : 884 - 891
  • [35] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Liang, Hongwei
    Du, Silin
    Yan, Gaowu
    Zhou, Yang
    Yang, Tianyu
    Zhang, Zhiwei
    Luo, Chenyi
    Liao, Hongfan
    Li, Yongmei
    ABDOMINAL RADIOLOGY, 2023, 48 (08) : 2596 - 2603
  • [36] Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction
    De Cecco, Carlo N.
    Muscogiuri, Giuseppe
    Schoepf, U. Joseph
    Caruso, Damiano
    Wichmann, Julian L.
    Cannao, Paola M.
    Canstein, Christian
    Fuller, Stephen R.
    Snider, Lauren
    Varga-Szemes, Akos
    Hardie, Andrew D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (07) : 1257 - 1264
  • [37] Task-Based Optimal Dose Partitioning in Dual-Source Dual-Energy CT for Virtual Non-Contrast and Iodine Imaging
    Long, L.
    McCollough, C.
    Yu, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E675 - E675
  • [38] Virtual Monochromatic Reconstruction of Dual-Energy Unenhanced Head CT at 65-75 keV Maximizes Image Quality Compared with Conventional Polychromatic CT
    Pomerantz, Stuart R.
    Kamalian, Shervin
    Zhang, Da
    Gupta, Rajiv
    Rapalino, Otto
    Sahani, Dushyant V.
    Lev, Michael H.
    RADIOLOGY, 2013, 266 (01) : 318 - 325
  • [39] Computed Tomography (CT) Venography With Dual-Energy CT: Low Tube Voltage and Dose Reduction of Contrast Medium for Detection of Deep Vein Thrombosis
    Ichikawa, Shintaro
    Ichikawa, Tomoaki
    Motosugi, Utaroh
    Imaizumi, Akira
    Sano, Katsuhiro
    Morisaka, Hiroyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (05) : 797 - 801
  • [40] Application of an Advanced Image-Based Virtual Monoenergetic Reconstruction of Dual Source Dual-Energy CT Data at Low keV Increases Image Quality for Routine Pancreas Imaging
    Hardie, Andrew D.
    Picard, Melissa M.
    Camp, E. Ramsay
    Perry, Jonathan D.
    Suranyi, Pal
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Wichmann, Julian L.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 716 - 720