Automated contouring and planning pipeline for hippocampal-avoidant whole-brain radiotherapy

被引:18
|
作者
Feng, Christine H. [1 ]
Cornell, Mariel [1 ]
Moore, Kevin L. [1 ]
Karunamuni, Roshan [1 ]
Seibert, Tyler M. [1 ,2 ]
机构
[1] Univ Calif San Diego, Dept Radiat Med & Appl Sci, Altman Clin & Translat Res Inst, 9500 Gilman Dr 0861, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Bioengn, La Jolla, CA 92093 USA
关键词
Brain metastases; Hippocampal-avoidant whole-brain radiotherapy; Artificial intelligence; Radiotherapy automation; Brain segmentation; Knowledge-based planning; SEGMENTATION; COST;
D O I
10.1186/s13014-020-01689-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Whole-brain radiotherapy (WBRT) remains an important treatment for over 200,000 cancer patients in the United States annually. Hippocampal-avoidant WBRT (HA-WBRT) reduces neurocognitive toxicity compared to standard WBRT, but HA-WBRT contouring and planning are more complex and time-consuming than standard WBRT. We designed and evaluated a workflow using commercially available artificial intelligence tools for automated hippocampal segmentation and treatment planning to efficiently generate clinically acceptable HA-WBRT radiotherapy plans. Methods We retrospectively identified 100 consecutive adult patients treated for brain metastases outside the hippocampal region. Each patient's T1 post-contrast brain MRI was processed using NeuroQuant, an FDA-approved software that provides segmentations of brain structures in less than 8 min. Automated hippocampal segmentations were reviewed for accuracy, then converted to files compatible with a commercial treatment planning system, where hippocampal avoidance regions and planning target volumes (PTV) were generated. Other organs-at-risk (OARs) were previously contoured per clinical routine. A RapidPlan knowledge-based planning routine was applied for a prescription of 30 Gy in 10 fractions using volumetric modulated arc therapy (VMAT) delivery. Plans were evaluated based on NRG CC001 dose-volume objectives (Brown et al. in J Clin Oncol, 2020). Results Of the 100 cases, 99 (99%) had acceptable automated hippocampi segmentations without manual intervention. Knowledge-based planning was applied to all cases; the median processing time was 9 min 59 s (range 6:53-13:31). All plans met per-protocol dose-volume objectives for PTV per the NRG CC001 protocol. For comparison, only 65.5% of plans on NRG CC001 met PTV goals per protocol, with 26.1% within acceptable variation. In this study, 43 plans (43%) met OAR constraints, and the remaining 57 (57%) were within acceptable variation, compared to 42.5% and 48.3% on NRG CC001, respectively. No plans in this study had unacceptable dose to OARs, compared to 0.8% of manually generated plans from NRG CC001. 8.4% of plans from NRG CC001 were not scored or unable to be evaluated. Conclusions An automated pipeline harnessing the efficiency of commercially available artificial intelligence tools can generate clinically acceptable VMAT HA-WBRT plans with minimal manual intervention. This process could improve clinical efficiency for a treatment established to improve patient outcomes over standard WBRT.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Application of a Novel Methodology for Efficient Optimization of Hippocampal Avoidance Whole-Brain Radiotherapy
    Azuz, R. Dadush
    Kindler, J.
    Gal, O.
    Limon, D.
    Fredman, E. T.
    Bragilovski, D. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E658 - E658
  • [22] Dosimetric Study and Neurocognitive Function of Hippocampal-Sparing Whole-Brain Radiotherapy
    Wang, Baohong
    Li, Hongfei
    Kong, Fanyang
    Xu, Dandan
    Zhang, Xudong
    Jia, Fei
    Lin, Yalei
    Li, Guowen
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 1266 - 1271
  • [23] Hippocampal-sparing whole-brain radiotherapy under coplanar or noncoplanar VMAT
    Chiang, Pin-Yi
    Hung, Chao-Hsiung
    Chang, Chih-Chia
    Lee, Cheng-Yen
    Wang, Yu -Wen
    Tsang, Yuk-Wah
    MEDICAL DOSIMETRY, 2023, 48 (03) : 134 - 139
  • [24] Semi-Automated Hippocampal Sparing Avoidance Whole-Brain Radiotherapy Using a Commercially Available Artificial Intelligence Toolkit
    Reynoso, F. J.
    Pryser, E.
    Hugo, G. D.
    Cai, B.
    Abraham, C. D., Jr.
    Henke, L. E.
    Huang, J.
    Perkins, S. M.
    Robinson, C. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E349 - E350
  • [25] Whole-brain radiotherapy in the management of brain metastasis
    Khuntia, D
    Brown, P
    Li, J
    Mehta, MP
    JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (08) : 1295 - 1304
  • [26] Hippocampus sparing in whole-brain radiotherapy
    Oskan, F.
    Ganswindt, U.
    Schwarz, S. B.
    Manapov, F.
    Belka, C.
    Niyazi, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 (04) : 337 - 341
  • [27] Dosimetric evaluation of a hybrid treatment planning for whole-brain radiation with hippocampal sparing
    Martin-Tovar, E. A.
    Badillo-Alvarado, A. H.
    Cocom-Poot, L. E.
    Gaxiola-Sosa, J. L.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2024, 22 (02): : 321 - 328
  • [28] Automated field-in-field whole brain radiotherapy planning
    Huang, Kai
    Hernandez, Soleil
    Wang, Chenyang
    Nguyen, Callistus
    Briere, Tina Marie
    Cardenas, Carlos
    Court, Laurence
    Xiao, Yao
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (02):
  • [29] WHOLE BRAIN RADIOTHERAPY WITH HIPPOCAMPAL AVOIDANCE: RE-EVALUATING THE NECESSITY OF THIN SLICE MRI FOR HIPPOCAMPAL CONTOURING
    Pelchat, Emilie
    Ward, Lucy
    Levangie, Natasha
    Best, Lara
    Mulroy, Liam
    Ha, Michael
    Thomas, Chris
    Day, Tracy
    RADIOTHERAPY AND ONCOLOGY, 2024, 198 : S37 - S37
  • [30] POST WHOLE-BRAIN RADIOTHERAPY HIPPOCAMPAL VOLUMETRY AND NEURONAL CHANGES MEASURED BY MR SPECTROSCOPY
    Kazda, T.
    Bulik, M.
    Pospisil, P.
    Nahodilova, J.
    Holikova, K.
    Burkon, P.
    Hynkova, L.
    Lakomy, R.
    Slampa, P.
    Jancalek, R.
    NEURO-ONCOLOGY, 2017, 19 : 48 - 48