Preliminary Study of a Low-Cost Point-of-Care Testing System Using Screen-Printed Biosensors for Early Biomarkers Detection Related to Alzheimer Disease

被引:0
|
作者
Tonello, Sarah [1 ]
Serpelloni, Mauro [1 ]
Lopomo, Nicola Francesco [1 ]
Abate, Giulia [2 ]
Uberti, Daniela Letizia [2 ]
Sardini, Emilio [1 ]
机构
[1] Univ Brescia, Dept Informat Engn, Via Branze 38, I-25123 Brescia, Italy
[2] Univ Brescia, Dept Mol & Translat Med, Via Branze 38, I-25123 Brescia, Italy
来源
SENSORS | 2018年 / 431卷
关键词
Screen printing; Electrochemical biosensors; Voltammetry; Point-of-care testing; GOLD NANOPARTICLES; PROTEIN-DETECTION; SENSOR; IMMUNOSENSOR; MARKER; P53;
D O I
10.1007/978-3-319-55077-0_32
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Among neurodegenerative diseases, Alzheimer Disease (AD) represents one of the most widespread pathologies, for which an early diagnosis is still missing. A peculiar expression of an altered conformational isoform of p53 protein was reported to be a potential biomarker able to distinguish AD subjects from healthy population, quantifiable using a blood-based enzyme-linked immunosorbent assay (ELISA). In order to overcome ELISA limitations, related to reliability and to improve sensitivity, this study aimed to realize a low cost highly sensitive portable point-of-care (PoC) testing system based on screen printed electrochemical sensors (SPES). The development of the platform specifically included both the design of the sensing probe and of the electronic circuit devoted to the conditioning and acquisition of the transduced electric signal. Preliminary testing of the circuit were performed recording changes in the conductivity of NaCl solution and quantifying electrodes coating with antibodies using Electrochemical Impedance Spectroscopy (EIS) principle. Results obtained with saline solution, showed the ability of the circuit to give the best response corresponding to low changes in NaCl concentration (sensitivity 0.2 mA/(mg/ml)), suggesting a good sensitivity of the platform. Findings obtained from EIS showed the ability of the circuit to discriminate between different concentrations of antibodies coatings (sensitivity 80 mu A/mu g). Preliminary calibration of the sensor using interleukin IL-8 showed an increase in the maximum peak of current proportional to the increase of protein concentration, achieving a sensitivity of 35 mu A/ng and reporting also a good value of reproducibility, really promising in the perspective of lower values of proteins concentrations.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 39 条
  • [21] Point-of-care rapid detection of Vibrio parahaemolyticus in seafood using loop-mediated isothermal amplification and graphene-based screen-printed electrochemical sensor
    Kampeera, Jantana
    Pasakon, Patiya
    Karuwan, Chanpen
    Arunrut, Narong
    Sappat, Assawapong
    Sirithammajak, Sarawut
    Dechokiattawan, Nipaphorn
    Sumranwanich, Thitinun
    Chaivisuthangkura, Parin
    Ounjai, Puey
    Chankhamhaengdecha, Surang
    Wisitsoraat, Anurat
    Tuantranont, Adisorn
    Kiatpathomchai, Wansika
    BIOSENSORS & BIOELECTRONICS, 2019, 132 : 271 - 278
  • [22] Enabling low-cost point-of-care ultrasound imaging system using single element transducer and delta configuration actuator
    Xu, Keshuai
    Kim, Younsu
    Boctor, Emad M.
    Zhang, Haichong K.
    MEDICAL IMAGING 2019: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2019, 10951
  • [23] Clinical significance of lipoarabinomannan detection in urine using a low-cost point-of-care diagnostic assay for HIV-associated tuberculosis
    Lawn, Stephen D.
    Kerkhoff, Andrew D.
    Vogt, Monica
    Wood, Robin
    AIDS, 2012, 26 (13) : 1635 - 1643
  • [24] Rapid, Low-Cost Measurement of Carotid Artery Distensibility in Children with Sickle Cell Disease Using Compact Point-of-Care Ultrasound
    Nguyen, Tracey
    Thien-Tyler Anh Nguyen
    Powell, Emily N.
    Chang, Alicia
    Bush, Adam
    BLOOD, 2023, 142
  • [25] A sensitive electrochemical detection of metronidazole in synthetic serum and urine samples using low-cost screen-printed electrodes modified with reduced graphene oxide and C60
    Elsa Maria Materón
    Ademar Wong
    Tayane Aguiar Freitas
    Ronaldo Censi Faria
    Osvaldo N.Oliveira Jr.
    JournalofPharmaceuticalAnalysis, 2021, 11 (05) : 646 - 652
  • [26] A sensitive electrochemical detection of metronidazole in synthetic serum and urine samples using low-cost screen-printed electrodes modified with reduced graphene oxide and C60
    Materon, Elsa Maria
    Wong, Ademar
    Freitas, Tayane Aguiar
    Faria, Ronaldo Censi
    Oliveira Jr, Osvaldo N.
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2021, 11 (05) : 646 - 652
  • [27] EasyNAT MTC assay: A simple, rapid, and low-cost cross-priming amplification method for the detection of mycobacterium tuberculosis suitable for point-of-care testing
    Zhang, Zhuman
    Du, Jian
    Liu, Tao
    Wang, Fen
    Jia, Junnan
    Dong, Lingling
    Zhao, Liping
    Xue, Yi
    Jiang, Guanglu
    Yu, Xia
    Huang, Hairong
    EMERGING MICROBES & INFECTIONS, 2021, 10 (01) : 1530 - 1535
  • [28] System-level integration of active silicon photonic biosensors using Fan-Out Wafer-Level-Packaging for low cost and multiplexed point-of-care diagnostic testing
    Laplatine, Loic
    Luan, Enxiao
    Cheung, Karen
    Ratner, Daniel M.
    Dattner, Yonathan
    Chrostowski, Lukas
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 1610 - 1617
  • [29] Developing a point-of-care System for Determination of Dopamine, Ascorbic and Uric Acids in Biological Fluids Using a Screen-Printed Electrode Modified by Three Dimensional Graphene/Carbon Nanotube Hybrid
    Farahani, Ali
    Sereshti, Hassan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 6195 - 6208
  • [30] Point-of-Care Detection of Carcinoembryonic Antigen (CEA) Using a Smartphone-Based, Label-Free Electrochemical Immunosensor with Multilayer CuONPs/CNTs/GO on a Disposable Screen-Printed Electrode
    Khonyoung, Supada
    Mangkronkaew, Praphatsorn
    Klayprasert, Puttaporn
    Puangpila, Chanida
    Palanisami, Muthukumaran
    Arivazhagan, Mani
    Jakmunee, Jaroon
    Biosensors, 2024, 14 (12):