Computer and robotic model of external fixation system for fracture treatment

被引:0
|
作者
Kim, YH [1 ]
Lee, SG [1 ]
机构
[1] Kyung Hee Univ, Sch Adv Technol, Yongin 449701, Kyongki Do, South Korea
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A computer graphic model combined with a robotic model of a unilateral external fixation system for a fractured tibia was developed to simulate the pre-operative planning of bone fracture and deformity correction by adjustment of fixator joints. An inverse kinematics analysis algorithm was developed to quantify the necessary rotations and translations at each joint of the fixator. The graphic model was developed using commercial CAD software, and the robotic model was developed to have same configurations. The accuracy of each motor in the robotic model was successfully tested. For a given rotational deformity with a fracture gap, the simulation results of the fracture reduction process were fully matched with the robotic execution. The presented models and techniques can be used for knowledge-based fracture treatment and bone deformity correction using external fixators.
引用
收藏
页码:1081 / 1087
页数:7
相关论文
共 50 条
  • [31] Biomechanical Analysis of the External Fixation in a Lumbar Fracture Model: A Finite Element Study
    Yijia Liao
    Yiguo Yan
    Yu Kang
    Wenjun Wang
    Xizheng Song
    Wen Peng
    Haibin Fu
    Huarong Chen
    Cheng Wang
    Journal of Medical and Biological Engineering, 2022, 42 : 469 - 478
  • [32] Conception of a navigation system controlling diaphyseal fracture reduction treated with external fixation
    Leloup, T.
    El Kazzi, W.
    Schuind, F.
    Warzee, N.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (01): : 99 - 109
  • [33] Application of Intelligent Computer-Assisted Taylor 3D External Fixation in the Treatment of Tibiofibular Fracture: Retrospective Case Study
    Sheng, Hongfeng
    Xu, Weixing
    Xu, Bin
    Song, Hongpu
    Lu, Di
    Ding, Weiguo
    Mildredl, Henry
    JMIR MEDICAL INFORMATICS, 2021, 9 (05)
  • [34] EXTERNAL FIXATION OF THE UNSTABLE ZYGOMATIC ARCH FRACTURE
    ASH, DC
    MERCURI, LG
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1984, 42 (09) : 621 - 622
  • [35] MEASUREMENT OF FRACTURE GAP MOTION IN EXTERNAL FIXATION
    SELIGSON, D
    POWERS, G
    OCONNELL, P
    POPE, MH
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1981, 21 (09): : 798 - 801
  • [36] Force measurement on fracture site with external fixation
    Z. G. Wang
    C. L. Peng
    X. L. Zheng
    P. Wang
    G. R. Wang
    Medical and Biological Engineering and Computing, 1997, 35 : 289 - 290
  • [37] MONITORING FRACTURE SITE PROPERTIES WITH EXTERNAL FIXATION
    BEAUPRE, GS
    HAYES, WC
    JOFE, MH
    WHITE, AA
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02): : 120 - 126
  • [38] Force measurement on fracture site with external fixation
    Wang, Z.G.
    Peng, C.L.
    Zheng, X.L.
    Wang, P.
    Wang, G.R.
    Medical and Biological Engineering and Computing, 1997, 35 (03): : 289 - 290
  • [39] Prototype of external fixation robot for fracture surgery
    Kim, Yoon Hyuk
    Lee, Soon-Gul
    2006 1ST IEEE RAS-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS, VOLS 1-3, 2006, : 1136 - +
  • [40] HOFFMAN EXTERNAL FIXATION OF DIAPHYSEAL FRACTURE OF THE HUMERUS
    LENOBLE, E
    TERRACHER, R
    KESSI, H
    GOUTALLIER, D
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1993, 79 (08): : 606 - 614