FBP initialization for transition artifacts reduction in statistical X-ray CT reconstruction.

被引:0
|
作者
Zbijewski, W [1 ]
Beekman, FJ [1 ]
机构
[1] UMC Utrecht, Imaging Sci Inst, Dept Nucl Med, NL-3584 CG Utrecht, Netherlands
关键词
imaging; maximum likelihood; tomography; iterative reconstruction; artifact reduction;
D O I
10.1109/NSSMIC.2003.1352507
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
When statistical reconstruction (SR) algorithms are applied to X-ray CT data, the resulting images may contain some disturbing streak artifacts emerging from high-contrast structures. Extremely high number of iterations needed to remove such disturbancies may seriously slow down the reconstruction process. In this paper we demonstrate (using the Ordered Subsets Convex algorithm) that these artifacts can be adequately suppressed if statistical reconstruction is initialized with images generated by means of analytical algorithms like Filtered Back Projection (FBP). This allows the reconstruction time to be shortened by even as much as one order of magnitude. Although the initialization of the statistical algorithm with FBP image introduces some additional noise into the first iteration of OSC reconstruction, the resolution-noise trade-off and the contrast-to-noise ratio of final images are not markedly compromised.
引用
收藏
页码:2970 / 2972
页数:3
相关论文
共 50 条
  • [31] Reduction of beam hardening artifacts in X-ray microtomography data
    Crostack, HA
    Nellesen, J
    NONDESTRUCTIVE CHARACTERIZATION OF MATERIALS XI, 2003, : 261 - 268
  • [32] Simultaneous Reduction in Noise and Cross-Contamination Artifacts for Dual-Energy X-Ray CT
    Li, Baojun
    Li, Baohong
    Luo, Jack
    Tang, Peng
    Mao, Jiandong
    Wu, Xiaoye
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [33] Complete Ring Artifacts Reduction Procedure for Lab-Based X-ray Nano CT Systems
    Salplachta, Jakub
    Zikmund, Tomas
    Zemek, Marek
    Brinek, Adam
    Takeda, Yoshihiro
    Omote, Kazuhiko
    Kaiser, Jozef
    SENSORS, 2021, 21 (01) : 1 - 20
  • [34] Metal Artifact Reduction in X-ray CT Imaging based on Iterative Reconstruction Approach
    Nawaz, Shoukat
    Jian, Fu
    2015 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2015, : 2420 - 2425
  • [35] ITERATIVE FBP FOR IMPROVED RECONSTRUCTION OF X-RAY DIFFERENTIAL PHASE-CONTRAST TOMOGRAMS
    Nilchian, Masih
    Vonesch, Cedric
    Modregger, Peter
    Stampanoni, Marco
    Unser, Michael
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1260 - 1263
  • [36] ARTIFACTS IN X-RAY MICROANALYSIS
    GALLE, P
    JOURNAL DE MICROSCOPIE ET DE BIOLOGIE CELLULAIRE, 1975, 22 (2-3): : 315 - 332
  • [37] Splitting-Based Statistical X-Ray CT Image Reconstruction with Blind Gain Correction
    Nien, Hung
    Fessler, Jeffrey A.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [38] Improving noise-resolution tradeoffs in X-ray CT imaging by statistical image reconstruction
    Williamson, J.
    Politte, D.
    O'Sullivan, J.
    Keesing, D.
    Whiting, B.
    Lazos, D.
    Evans, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2346 - 2346
  • [39] Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review
    Zhang, Hao
    Wang, Jing
    Zeng, Dong
    Tao, Xi
    Ma, Jianhua
    MEDICAL PHYSICS, 2018, 45 (10) : E886 - E907
  • [40] Simplified Statistical Image Reconstruction for X-ray CT With Beam-Hardening Artifact Compensation
    Abella, Monica
    Martinez, Cristobal
    Desco, Manuel
    Jose Vaquero, Juan
    Fessler, Jeffrey A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (01) : 111 - 118