Simulated daily plan adaptation for magnetic resonance-guided liver stereotactic body radiotherapy

被引:0
|
作者
Taylor, Edward [1 ,2 ]
Lukovic, Jelena [1 ,2 ]
Velec, Michael [1 ,2 ]
Shessel, Andrea [1 ]
Stanescu, Teodor [1 ,2 ]
Dawson, Laura [1 ,2 ]
Letourneau, Daniel [1 ,2 ]
Lindsay, Patricia [1 ,2 ]
机构
[1] Princess Margaret Canc Ctr, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
关键词
Image guided radiotherapy; magnetic resonance imaging; liver cancer; stereotactic body radiotherapy; RADIATION-THERAPY SMART; MALIGNANCIES; ABDOMEN; PELVIS; THORAX; IMPACT;
D O I
10.1080/0284186X.2020.1840625
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction Liver cancers are challenging to treat using image-guided radiotherapy (IGRT) due to motion and deformation of target volumes and organs at risk (OARs), as well as difficulties in visualising liver tumours using cone-beam computed tomography (CBCT) based IGRT. Liver cancer patients may thus benefit from magnetic resonance (MR)-guided daily adaptive re-planning. We evaluated the dosimetric impact of a daily plan adaptation strategy based on daily MR imaging versus CBCT-based IGRT. Methods Ten patients were studied who were treated with CBCT-guided five-fraction stereotactic body radiotherapy (SBRT) and underwent MR imaging before each fraction. Simulated reference plans were created on computer tomography (CT) images and adapted plans were created on the daily MR images. Two plan adaptation strategies were retrospectively simulated: (1) translational couch shifts to match liver, mimicking standard CBCT guidance and (2) daily plan adaptation based on reference plan clinical goals and daily target and OAR contours. Dose statistics were calculated for both strategies and compared. Results Couch shifts resulted in an average reduction in GTV D99% relative to reference plan values of 5.2 Gy (-12.5% of reference values). Daily plan adaptation reduced this to 0.8 Gy (-2.0%). For six patients who were OAR dose-limited on reference plans, couch shifts resulted in OAR dose violations in 28 out of 28 simulated fractions, respectively; no violations occurred using daily plan adaptation. No OAR dose violations occurred using either strategy for the four cases not OAR dose-limited at reference planning. Conclusions MR-guided daily plan adaptation ensured OAR dose constraints were met at all simulated treatment fractions while CBCT-based IGRT resulted in a systematic over-dosing of OARs in patients whose doses were limited by OAR dose at the time of reference planning.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [41] Clinical Applications of Magnetic Resonance-Guided Radiotherapy: A Narrative Review
    Ladbury, Colton
    Amini, Arya
    Schwer, Amanda
    Liu, An
    Williams, Terence
    Lee, Percy
    CANCERS, 2023, 15 (11)
  • [42] Magnetic Resonance-Guided Stereotactic Biopsies: Results in 100 Consecutive Cases
    D. Fontaine
    D. Dormont
    D. Hasboun
    S. Clemenceau
    Ch. Valery
    C. Oppenheim
    M. Sahel
    C. Marsault
    J. Philippon
    P. Cornu
    Acta Neurochirurgica, 2000, 142 : 249 - 256
  • [43] Magnetic resonance-guided stereotactic body radiation therapy for pancreatic oligometastases from renal cell carcinoma
    van Vulpen, Jonna K.
    Eijkelenkamp, Hidde
    Grimbergen, Guus
    Wessels, Frank J.
    Mulder, Sasja F.
    Meijer, Gert J.
    Intven, Martijn P. W.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [44] Repeated Magnetic Resonance Image-guided Stereotactic body Radiotherapy for oligometastatic patients
    Panza, G.
    Chiloiro, G.
    Boldrini, L.
    Romano, A.
    Placidi, L.
    Nardini, M.
    Galetto, M.
    Cellini, F.
    Valentini, V.
    Gambacorta, M. A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1111 - S1112
  • [45] Evaluating dose constraints for radiation induced liver damage following magnetic resonance image guided Stereotactic Body radiotherapy
    Yadav, Poonam
    Kuczmarska-Haas, Aleksandra
    Musunuru, Hima Bindu
    Witt, Jacob
    Blitzer, Grace
    Mahler, Peter
    Bassetti, Michael F.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 17 : 91 - 94
  • [46] Multi-parametric optimization of magnetic resonance imaging sequences for magnetic resonance-guided radiotherapy
    Fahad, Hafiz Muhammad
    Dorsch, Stefan
    Zaiss, Moritz
    Karger, Christian P.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 28
  • [47] Robustness of radiomics features on 0.35 T magnetic resonance imaging for magnetic resonance-guided radiotherapy
    Michalet, Morgan
    Valenzuela, Gladis
    Debuire, Pierre
    Riou, Olivier
    Azria, David
    Nougaret, Stephanie
    Tardieu, Marion
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [48] Magnetic resonance-guided stereotactic body radiation therapy (MRgSBRT) for oligometastatic patients: a single-center experience
    Chiloiro, Giuditta
    Boldrini, Luca
    Romano, Angela
    Placidi, Lorenzo
    Tran, Huong Elena
    Nardini, Matteo
    Massaccesi, Mariangela
    Cellini, Francesco
    Indovina, Luca
    Gambacorta, Maria Antonietta
    RADIOLOGIA MEDICA, 2023, 128 (05): : 619 - 627
  • [49] Clinical Outcomes Using Magnetic Resonance-Guided Stereotactic Body Radiation Therapy in Patients With Locally Advanced Cholangiocarcinoma
    Luterstein, Elaine
    Cao, Minsong
    Lamb, James M.
    Raldow, Ann
    Low, Daniel
    Steinberg, Michael L.
    Lee, Percy
    ADVANCES IN RADIATION ONCOLOGY, 2020, 5 (02) : 189 - 195
  • [50] Simulated Online Adaptive Magnetic Resonance-Guided Stereotactic Body Radiation Therapy for the Treatment of Oligometastatic Disease of the Abdomen and Central Thorax: Characterization of Potential Advantages
    Henke, Lauren
    Kashani, Rojano
    Yang, Deshan
    Zhao, Tianyu
    Green, Olga
    Olsen, Lindsey
    Rodriguez, Vivian
    Wooten, H. Omar
    Li, H. Harold
    Hu, Yanle
    Bradley, Jeffrey
    Robinson, Clifford
    Parikh, Parag
    Michalski, Jeff
    Mutic, Sasa
    Olsen, Jeffrey R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (05): : 1078 - 1086