Three Dimensional Ultra-short Echo Time MRI Can Depict Cholesterol Components of Gallstones Bright

被引:4
|
作者
Takahashi, Mamoru [1 ]
Takehara, Yasuo [2 ]
Fujisaki, Kenji [3 ]
Okuaki, Tomoyuki [4 ]
Fukuma, Yukiko [4 ]
Tooyama, Norihiro [1 ]
Ichijo, Katsutoshi [1 ]
Amano, Tomoyasu [5 ]
Goshima, Satoshi [6 ]
Naganawa, Shinji [7 ]
机构
[1] Seirei Mikatahara Gen Hosp, Dept Radiol, Hamamatsu, Shizuoka, Japan
[2] Nagoya Univ, Dept Fundamental Dev Adv Low Invas Diagnost Imagi, Grad Sch Med, Nagoya, Aichi, Japan
[3] Seirei Med Checkup Ctr, Hamamatsu, Shizuoka, Japan
[4] Philips Japan Ltd, Tokyo, Japan
[5] Seirei Mikatahara Gen Hosp, Dept Radiol Technol, Hamamatsu, Shizuoka, Japan
[6] Hamamatsu Univ Sch Med, Dept Diagnost Radiol & Nucl Med, Hamamatsu, Shizuoka, Japan
[7] Nagoya Univ, Dept Radiol, Grad Sch Med, Nagoya, Aichi, Japan
关键词
cholelithiasis; cholesterol gallstone; magnetic resonance; ultrashort echo time; GALLBLADDER-DISEASE; CT; CHOLELITHIASIS; EPIDEMIOLOGY; TOMOGRAPHY; DIAGNOSIS; PITFALLS; STONES; IMAGES;
D O I
10.2463/mrms.mp.2020-0009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Non-calcified cholesterol stones that are small in size are hard to be depicted on CT or magnetic resonance cholangiopancreatography. This institutional review board (IRB)-approved retrospective in vitro study aims to characterize contrast behaviors of 3 main components of the gallstones, i.e., cholesterol component and to test the capability of depicting CC of gallstones as bright signals as compared to background saline. Methods: Fourteen representative gallstones from 14 patients, including 15 CC, 6 BC and 4 CO, were enrolled. The gallstones underwent MRI including fat-saturated T1-weighted image (fs-T1WI) and UTE MRI with dual echoes. The contrast-to-noise ratio (CNR) and the chemical analysis for the 25 portions of the stones were compared. Results: BC was bright on fs-T1WI, which did not change dramatically on UTE MRI and the signal did not remain on UTE subtraction image between dual echoes. Whereas the CC was negative or faintly positive signal on fs-T1WI, bright signal on UTE MRI and the contrast remained even higher on the UTE subtraction, which reflected their short T2 values. Median CNRs and standard errors of the segments on each imaging were as follows: on fs-T1WI, -10.2 +/- 4.2 for CC, 149.7 +/- 27.6 for BC and 37.9 +/- 14.3 for CO; on UTE MRI first echo, 16.7 +/- 3.3 for CC, 74.9 +/- 21.3 for BC and 17.7 +/- 8.4 for CO; on UTE subtraction image, 30.2 +/- 2.0 for CC, -11.2 +/- 5.4 for BC and 17.8 +/- 10.7 for CO. Linear correlations between CNRs and cholesterol concentrations were observed on fs-T1WI with r = -0.885, (P < 0.0001), UTE MRI first echo r = -0.524 (P = 0.0072) and UTE subtraction with r = 0.598 (P = 0.0016). Conclusion: UTE MRI and UTE subtraction can depict CC bright.
引用
收藏
页码:359 / 370
页数:12
相关论文
共 50 条
  • [21] Design and development of a novel flexible ultra-short echo time (FUSE) sequence
    Cui, Lumeng
    McWalter, Emily J.
    Moran, Gerald
    Venugopal, Niranjan
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (05) : 1905 - 1918
  • [22] Ultra-short echo time cardiovascular magnetic resonance of atherosclerotic carotid plaque
    Chan, Cheuk F.
    Keenan, Niall G.
    Nielles-Vallespin, Sonia
    Gatehouse, Peter
    Sheppard, Mary N.
    Boyle, Joseph J.
    Pennell, Dudley J.
    Firmin, David N.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12
  • [23] Ultra-short echo time cardiovascular magnetic resonance of atherosclerotic carotid plaque
    Cheuk F Chan
    Niall G Keenan
    Sonia Nielles-Vallespin
    Peter Gatehouse
    Mary N Sheppard
    Joseph J Boyle
    Dudley J Pennell
    David N Firmin
    Journal of Cardiovascular Magnetic Resonance, 12
  • [24] Assessment of porosity index of the femoral neck and tibia by 3D ultra-short echo-time MRI
    Chen, Min
    Yuan, Huishu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (03) : 820 - 828
  • [25] Pulmonary Structural MRI using Free-Breathing, Self-Gated Ultra-short Echo Time Imaging
    Niedbalski, Peter J.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (211):
  • [26] Vessel-based lung lobe partitioning in ultra-short time echo proton MRI for regional ventilation assessment
    Khiati, Rezkellah-Noureddine
    Didier, Antoine
    Barrau, Nathalie
    Justet, Aurelien
    Maitre, Xavier
    Bernaudin, Jean-Francois
    Brillet, Pierre-Yves
    Tapu, Ruxandra
    Ispas, Radu
    Fetita, Catalin
    COMPUTER-AIDED DIAGNOSIS, MEDICAL IMAGING 2024, 2024, 12927
  • [27] COMPRESSED SENSING WITH NON-UNIFORM FAST FOURIER TRANSFORM FOR RADIAL ULTRA-SHORT ECHO TIME (UTE) MRI
    Yang, Xiahan
    Zheng, Yahong Rosa
    Yang, Ming
    Ma, Lixin
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 918 - 921
  • [28] Ventilation/Perfusion Imaging of the Lung Using Ultra-short Echo Time (UTE) MRI in an Animal Model of Pulmonary Embolism
    Togao, Osamu
    Ohno, Yoshiharu
    Dimitrov, Ivan
    Hsia, Connie C.
    Takahashi, Masaya
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (03) : 539 - 546
  • [29] Development of 3D Rosette K-Space Trajectory in Ultra-Short Echo Time MRI Applications
    Shen, X.
    Chiew, M.
    Emir, U.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [30] A Modified EPI Sequence for High-Resolution Imaging at Ultra-Short Echo Time
    Hetzer, Stefan
    Mildner, Toralf
    Moeller, Harald E.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) : 165 - 175