Three Dimensional Ultra-short Echo Time MRI Can Depict Cholesterol Components of Gallstones Bright

被引:4
|
作者
Takahashi, Mamoru [1 ]
Takehara, Yasuo [2 ]
Fujisaki, Kenji [3 ]
Okuaki, Tomoyuki [4 ]
Fukuma, Yukiko [4 ]
Tooyama, Norihiro [1 ]
Ichijo, Katsutoshi [1 ]
Amano, Tomoyasu [5 ]
Goshima, Satoshi [6 ]
Naganawa, Shinji [7 ]
机构
[1] Seirei Mikatahara Gen Hosp, Dept Radiol, Hamamatsu, Shizuoka, Japan
[2] Nagoya Univ, Dept Fundamental Dev Adv Low Invas Diagnost Imagi, Grad Sch Med, Nagoya, Aichi, Japan
[3] Seirei Med Checkup Ctr, Hamamatsu, Shizuoka, Japan
[4] Philips Japan Ltd, Tokyo, Japan
[5] Seirei Mikatahara Gen Hosp, Dept Radiol Technol, Hamamatsu, Shizuoka, Japan
[6] Hamamatsu Univ Sch Med, Dept Diagnost Radiol & Nucl Med, Hamamatsu, Shizuoka, Japan
[7] Nagoya Univ, Dept Radiol, Grad Sch Med, Nagoya, Aichi, Japan
关键词
cholelithiasis; cholesterol gallstone; magnetic resonance; ultrashort echo time; GALLBLADDER-DISEASE; CT; CHOLELITHIASIS; EPIDEMIOLOGY; TOMOGRAPHY; DIAGNOSIS; PITFALLS; STONES; IMAGES;
D O I
10.2463/mrms.mp.2020-0009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Non-calcified cholesterol stones that are small in size are hard to be depicted on CT or magnetic resonance cholangiopancreatography. This institutional review board (IRB)-approved retrospective in vitro study aims to characterize contrast behaviors of 3 main components of the gallstones, i.e., cholesterol component and to test the capability of depicting CC of gallstones as bright signals as compared to background saline. Methods: Fourteen representative gallstones from 14 patients, including 15 CC, 6 BC and 4 CO, were enrolled. The gallstones underwent MRI including fat-saturated T1-weighted image (fs-T1WI) and UTE MRI with dual echoes. The contrast-to-noise ratio (CNR) and the chemical analysis for the 25 portions of the stones were compared. Results: BC was bright on fs-T1WI, which did not change dramatically on UTE MRI and the signal did not remain on UTE subtraction image between dual echoes. Whereas the CC was negative or faintly positive signal on fs-T1WI, bright signal on UTE MRI and the contrast remained even higher on the UTE subtraction, which reflected their short T2 values. Median CNRs and standard errors of the segments on each imaging were as follows: on fs-T1WI, -10.2 +/- 4.2 for CC, 149.7 +/- 27.6 for BC and 37.9 +/- 14.3 for CO; on UTE MRI first echo, 16.7 +/- 3.3 for CC, 74.9 +/- 21.3 for BC and 17.7 +/- 8.4 for CO; on UTE subtraction image, 30.2 +/- 2.0 for CC, -11.2 +/- 5.4 for BC and 17.8 +/- 10.7 for CO. Linear correlations between CNRs and cholesterol concentrations were observed on fs-T1WI with r = -0.885, (P < 0.0001), UTE MRI first echo r = -0.524 (P = 0.0072) and UTE subtraction with r = 0.598 (P = 0.0016). Conclusion: UTE MRI and UTE subtraction can depict CC bright.
引用
收藏
页码:359 / 370
页数:12
相关论文
共 50 条
  • [1] Quantifying cortical bone water in vivo by three-dimensional ultra-short echo-time MRI
    Rad, Hamidreza Saligheh
    Lam, Shing Chun Benny
    Magland, Jeremy F.
    Ong, Henry
    Li, Cheng
    Song, Hee Kwon
    Love, James
    Wehrli, Felix W.
    NMR IN BIOMEDICINE, 2011, 24 (07) : 855 - 864
  • [2] Three-dimensional accurate detection of lung emphysema in rats using ultra-short and zero echo time MRI
    Bianchi, Andrea y
    Tibiletti, Marta
    Kjorstad, Asmund
    Birk, Gerald
    Schad, Lothar R.
    Stierstorfer, Birgit
    Rasche, Volker
    Stiller, Detlef
    NMR IN BIOMEDICINE, 2015, 28 (11) : 1471 - 1479
  • [3] MRI of the brain with ultra-short echo-time pulse sequences
    Waldman, A
    Rees, JH
    Brock, CS
    Robson, MD
    Gatehouse, PD
    Bydder, GM
    NEURORADIOLOGY, 2003, 45 (12) : 887 - 892
  • [4] MRI of the brain with ultra-short echo-time pulse sequences
    A. Waldman
    J. H. Rees
    C. S. Brock
    M. D. Robson
    P. D. Gatehouse
    G. M. Bydder
    Neuroradiology, 2003, 45 : 887 - 892
  • [5] Quantitative Assessment of Tracheomalacia Using Ultra-Short Echo Time MRI
    Hysinger, E.
    Bates, A.
    Higano, N. S.
    Hart, C. K.
    Benscoter, D.
    de Alacron, A.
    Fain, S. B.
    Kingma, P. S.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [6] The application of ultra-short echo time MRI (UTE) for the structural assessment of dental hard-tissue components
    Rasche, Volker
    Hofmann, Christian
    Maschka, Regina
    Ulrici, Johannes
    Hell, Erich
    Haller, Bernd
    Boujraf, Said
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 11: BIOMEDICAL ENGINEERING FOR AUDIOLOGY, OPHTHALMOLOGY, EMERGENCY AND DENTAL MEDICINE, 2009, 25 (11): : 65 - +
  • [7] Use of Ultra-Short Echo Time MRI to Improve Temporal Bone Imaging
    Kaufman, A. C.
    Fu, F.
    Martinez, M. C.
    Fischbein, N.
    Popelka, G. R.
    Pauly, K. Butts
    Blevins, N. H.
    LARYNGOSCOPE, 2024, 134 (11): : 4691 - 4696
  • [8] The application value of ultra-short echo time MRI in the quantification of liver iron overload in a rat model
    Wu, Qiaoling
    Fu, Xiuwei
    Zhuo, Zhizheng
    Zhao, Mingfeng
    Ni, Hongyan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (02) : 180 - 187
  • [9] Ultra-short Echo-Time Pulmonary MRI: Evaluation and Reproducibility in COPD Subjects With and Without Bronchiectasis
    Ma, Weijing
    Sheikh, Khadija
    Svenningsen, Sarah
    Pike, Damien
    Guo, Fumin
    Etemad-Rezai, Roya
    Leipsic, Jonathan
    Coxson, Harvey O.
    McCormack, David G.
    Parraga, Grace
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (05) : 1465 - 1474
  • [10] Viability of Oxygen-enhanced Ventilation Imaging of the Lungs Using Ultra-short Echo Time MRI
    Sasaki, Tomoaki
    Takahashi, Koji
    Obara, Makoto
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (03) : 259 - 261