On the scintillation efficiency of carborane-loaded liquid scintillators for thermal neutron detection

被引:15
|
作者
Chang, Zheng [1 ]
Okoye, Nkemakonam C. [1 ]
Urffer, Matthew J. [2 ]
Green, Alexander D. [2 ]
Childs, Kyle E. [1 ]
Miller, Laurence F. [2 ]
机构
[1] South Carolina State Univ, Appl Radiat Sci Lab, Orangeburg, SC 29117 USA
[2] Univ Tennessee, Dept Nucl Engn, Knoxville, TN 37996 USA
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2015年 / 769卷
关键词
Neutron detection; Liquid organic scintillator; Carborane; Scintillation efficiency; Birks factor; Quench constant; RESONANCE ENERGY-TRANSFER;
D O I
10.1016/j.nima.2014.09.066
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The scintillation efficiency in response to thermal neutrons was studied by loading different concentrations of carborane (0-8.5 wt%) and naphthalene (0 and 100 g/L) in five liquid organic scintillators. The sample was characterized in Pb and Cd shields under the irradiation of the thermal neutrons from a Cf-252 source. A method was developed to extract the net neutron response from the pulse-height spectra. It was found that the order of scintillation efficiencies for both gamma-rays and thermal neutrons is as follows: diisopropylnaphthalene > toluene (concentrated solutes) > toluene similar to pseudocumene similar to m-xylene. The quench constants, obtained by fitting the Stern-Volmer model to the plots of light output versus carborane concentration, are in the range of 0.35-1.4 M-1 for all the scintillators. The Birks factors, estimated using the specific energy loss profiles of the incident particles, are in the range of 9.3-14 mg cm(-2) MeV-1 for all the samples. The light outputs are in the range of 63-86 keV electron equivalents (keVee) in response to thermal neutrons. Loading naphthalene generally promotes the scintillation efficiency of the scintillator with a benzene derivative solvent. Among all the scintillators tested, the diisopropylnaphthalene-based scintillator shows the highest scintillation efficiency, lowest Birks factor, and smallest quench constants. These properties are primarily attributed to the double fused benzene-ring structure of the solvent, which is more efficient to populate to the excited singlet state under ionizing radiation and to transfer the excitation energy to the fluorescent solutes. Published by Elsevier B.V.
引用
收藏
页码:112 / 122
页数:11
相关论文
共 50 条
  • [31] Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection
    Egner, Bryan, V
    Febbraro, Michael
    Bevins, James E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 996
  • [32] STATISTICS OF COINCIDENCE DETECTION EFFICIENCY IN LIQUID SCINTILLATION SPECTROMETRY
    JORDAN, P
    NUCLEAR INSTRUMENTS & METHODS, 1971, 97 (01): : 107 - &
  • [33] A BORON-LOADED LIQUID SCINTILLATION NEUTRON DETECTOR USING A SINGLE PHOTOMULTIPLIER
    THOMAS, GE
    NUCLEAR INSTRUMENTS & METHODS, 1962, 17 (02): : 137 - 139
  • [34] Suppression of gamma-ray sensitivity of liquid scintillators for neutron detection
    Swiderski, L.
    Moszynski, M.
    Wolski, D.
    Iwanowska, J.
    Szczesniak, T.
    Schotanus, P.
    Hurlbut, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 330 - 333
  • [35] Comparison of deuterated and normal liquid scintillators for fast-neutron detection
    Bildstein, V.
    Garrett, P. E.
    Wong, J.
    Bandyopadhyay, D.
    Bangay, J.
    Bianco, L.
    Hadinia, B.
    Leach, K. G.
    Sumithrarachchi, C.
    Ashley, S. F.
    Crider, B. P.
    McEllistrem, M. T.
    Peters, E. E.
    Prados-Estevez, F. M.
    Yates, S. W.
    Vanhoy, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 188 - 197
  • [36] ZnS quantum dot based nanocomposite scintillators for thermal neutron detection
    Wang, C. L.
    Gou, L.
    Zaleski, J. M.
    Friesel, D. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01): : 186 - 190
  • [37] Characterization of a 6Li-loaded liquid organic scintillator for fast neutron spectrometry and thermal neutron detection
    Bass, C. D.
    Beise, E. J.
    Breuer, H.
    Heimbach, C. R.
    Langford, T. J.
    Nico, J. S.
    APPLIED RADIATION AND ISOTOPES, 2013, 77 : 130 - 138
  • [38] A Comparison of Fast Inorganic Scintillators for Thermal Neutron Analysis Landmine Detection
    McFee, John E.
    Faust, Anthony A.
    Andrews, H. Robert
    Kovaltchouk, Vitaly
    Clifford, Edward T.
    Ing, Harry
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 1584 - 1592
  • [39] Development of LiAlO2 nanoparticle-loaded plastic scintillators for neutron detection
    Tsukahara, Haruhisa
    Fujimoto, Yutaka
    Asai, Keisuke
    Koshimizu, Masanori
    JOURNAL OF LUMINESCENCE, 2024, 271
  • [40] Cu-Doped Cs₂AgI₃ Composite-Loaded Plastic Scintillators for X-Ray and Thermal Neutron Detection
    Gui, Wanting
    Yao, Lu
    Zhou, Xunsheng
    Wu, Qi
    Li, Chao
    Zhang, Shi
    Zhan, Yunfeng
    Wang, Cai Lin
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2025, 72 (01) : 38 - 45