Whole-Heart Contrast-Enhanced Coronary Magnetic Resonance Angiography Using Gradient Echo Interleaved EPI

被引:6
|
作者
Bhat, Himanshu [2 ,3 ]
Zuehlsdorff, Sven [1 ]
Bi, Xiaoming [1 ]
Li, Debiao [2 ,3 ]
机构
[1] Siemens Med Solut USA Inc, Chicago, IL USA
[2] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
coronary arteries; magnetic resonance angiography; interleaved EPI; contrast media; MR-ANGIOGRAPHY; VOLUME; MOTION; ARTERIES; MINUTES; SCANNER; HUMANS; 3T;
D O I
10.1002/mrm.21963
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Whole-heart coronary MR angiography (MRA) is a promising method for detecting coronary artery disease. However, the imaging time is relatively long (on the order of 10-15 min). Such a long imaging time may result in patient discomfort and compromise the robustness of whole-heart coronary MRA due to increased respiratory and cardiac motion artifacts. The goal of this study was to optimize a gradient echo interleaved echo planar imaging (GRE-EPI) acquisition scheme for reducing the imaging time of contrast-enhanced whole-heart coronary MRA. Numerical simulations and phantom studies were used to optimize the GRE-EPI sequence parameters. Healthy volunteers were scanned with both the proposed GRE-EPI sequence and a 3D TrueFISP sequence for comparison purposes. Slow infusion (0.5 cc/sec) of Gd-DTPA was used to enhance the signal-to-noise ratio (SNR) of the GRE-EPI acquisition. Whole-heart images with the GRE-EPI technique were acquired with a true resolution of 1.0 x 1.1 x 2.0 mm(3) in an average scan time of 4.7 +/- 0.7 min with an average navigator efficiency of 44 +/- 6%. The GRE-EPI acquisition showed excellent delineation of all the major coronary arteries with scan time reduced by a factor of 2 compared with the TrueFISP acquisition. Magn Reson Med 61: 1388-1395, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1388 / 1395
页数:8
相关论文
共 50 条
  • [31] Diagnostic performance of non-contrast-enhanced whole-heart magnetic resonance coronary angiography in combination with adenosine stress perfusion cardiac magnetic resonance imaging
    Heer, Tobias
    Reiter, Stephanie
    Hoefling, Berthold
    Pilz, Guenter
    AMERICAN HEART JOURNAL, 2013, 166 (06) : 999 - 1009
  • [32] Prospective heart tracking for whole-heart magnetic resonance angiography
    Moghari, Mehdi H.
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 759 - 765
  • [33] 3.0T Contrast-enhanced whole-heart coronary magnetic resonance angiography for simultaneous coronary artery angiography and myocardial viability in chronic myocardial infarction A single-center preliminary study
    Chen, Zhiyong
    Sun, Bin
    Duan, Qing
    Xue, Yunjing
    Chen, Lianglong
    MEDICINE, 2018, 97 (45)
  • [34] Diagnostic Performance of Self-navigated Whole-Heart Contrast-enhanced Coronary 3-T MR Angiography
    He, Yi
    Pang, Jianing
    Dai, Qinyi
    Fan, Zhanming
    An, Jing
    Li, Debiao
    RADIOLOGY, 2016, 281 (02) : 401 - 408
  • [35] Anomalous origin of the right coronary artery: Depiction at whole-heart coronary magnetic resonance angiography
    Sato, Yuichi
    Matsumoto, Naoya
    Komatsu, Sei
    Kunimasa, Taeko
    Yoda, Shunichi
    Tani, Shigemasa
    Kunimoto, Satoshi
    Achenbach, Stephan
    Saito, Satoshi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 127 (02) : 274 - 275
  • [36] Contrast-Enhanced Whole-Heart Coronary MRA using Gadofosveset: 3.0 T versus 1.5 T
    Prompona, Maria
    Cyran, Clemens
    Nikolaou, Konstantin
    Bauner, Kerstin
    Reiser, Maximilian
    Huber, Armin
    ACADEMIC RADIOLOGY, 2010, 17 (07) : 862 - 870
  • [37] 102 Diagnostic value of contrast-enhanced whole-heart coronary MRA at 3 Tesla
    Qi Yang
    Debiao Li
    Xiaoming Bi
    Jing An
    Qiang Zhang
    Renate Jerecic
    Kuncheng Li
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [38] Feasibility of contrast-enhanced coronary artery magnetic resonance angiography using compressed sensing
    Hirai, Kuniaki
    Kido, Teruhito
    Kido, Tomoyuki
    Ogawa, Ryo
    Tanabe, Yuki
    Nakamura, Masashi
    Kawaguchi, Naoto
    Kurata, Akira
    Watanabe, Kouki
    Yamaguchi, Osamu
    Schmidt, Michaela
    Forman, Christoph
    Mochizuki, Teruhito
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [39] Feasibility of contrast-enhanced coronary artery magnetic resonance angiography using compressed sensing
    Kuniaki Hirai
    Teruhito Kido
    Tomoyuki Kido
    Ryo Ogawa
    Yuki Tanabe
    Masashi Nakamura
    Naoto Kawaguchi
    Akira Kurata
    Kouki Watanabe
    Osamu Yamaguchi
    Michaela Schmidt
    Christoph Forman
    Teruhito Mochizuki
    Journal of Cardiovascular Magnetic Resonance, 22
  • [40] Depiction of reperfused myocardial infarction using contrast-enhanced spin echo and gradient echo magnetic resonance imaging
    Geschwind, JFH
    Saeed, M
    Wendland, MF
    Higgins, CB
    INVESTIGATIVE RADIOLOGY, 1998, 33 (07) : 386 - 392