RESEARCH ON THE MOIRE CHROMATOGRAPHY TECHNIQUE AND ITS APPLICATION

被引:0
|
作者
Li, Tianze [1 ]
Yan, Hongmeng [1 ]
Tan, Boxue [1 ]
Li, Zhenmei [1 ]
Wang, Shuyun [1 ]
机构
[1] Shandong Univ Technol, Sch Elect & Elect Engn, Zibo 23504, Peoples R China
关键词
D O I
10.1142/9789812832344_0009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Expound the Moire chromatography technique and the optical characteristics when the light crosses the air flow field. Based oil this. taking grating, CCD camera, optical filter and diaphragm etc as the main device. a multi-direction Moire chromatography optical system is designed. The system is consist of five detective light paths,, in each detective light paths there is parallel and same periodic grating, and filtering minipore placed on the lens focal length plane, the,rating is used to adjust the space length and included angle between the two grating: and the filtering, minipore is Used to remove the unorderly frequency intermixed in the Moire fringe. Utilize the computer escalator method to convert the tested Value. the vivid interference fringe of tested parameter call be obtained. In the end analyze and discuss the application of this system in precision measurement and medicine project,
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [21] MOIRE TOPOGRAPHY FROM ITS BIRTH TO PRACTICAL APPLICATION
    TAKASAKI, H
    OPTICS AND LASERS IN ENGINEERING, 1982, 3 (01) : 3 - 14
  • [22] Fabrication of high temperature moire grating and its application
    Wang, Huaixi
    Xie, Huimin
    Li, Yanjie
    Fang, Peng
    Dai, Xianglu
    Wu, Lifu
    Tang, Minjin
    OPTICS AND LASERS IN ENGINEERING, 2014, 54 : 255 - 262
  • [23] Alignment model of moire and its application in nanometer lithography
    Zhou, Shao-Lin
    Chen, Wang-Fu
    Yang, Yong
    Tang, Xiao-Ping
    Hu, Song
    Ma, Ping
    Yan, Wei
    Zhang, You-Lin
    Guangdian Gongcheng/Opto-Electronic Engineering, 2008, 35 (09): : 27 - 31
  • [24] AE technique and its application in characteristic research of mechanical processing
    Chen, X.
    Kong, F.
    Liao, J.
    Changsha Dianli Xueyuan Xuebao/Journal of Changsha University of Electric Power, 2000, 15 (04): : 70 - 71
  • [25] Analysis of proguanil and its metabolites by application of the sweeping technique in micellar electrokinetic chromatography
    Taylor, RB
    Reid, RG
    Low, AS
    JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) : 201 - 206
  • [26] TRENDS OF MOIRE TECHNIQUE
    HEYMANN, J
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1972, 52 (10): : T320 - T326
  • [27] Application of a birefringent lens in photoelastic studies using a coherent moire technique
    Bhadra, SK
    Sarkar, SK
    Chakraborty, RN
    Sengupta, K
    Basuray, A
    JOURNAL OF MODERN OPTICS, 1996, 43 (10) : 2009 - 2017
  • [28] Application of phase shifting technique for SEM scanning moire method in MEMS
    Shang, HX
    Xie, HM
    Dai, FL
    OPTICAL TECHNOLOGY AND IMAGE PROCESSING FOR FLUIDS AND SOLIDS DIAGNOSTICS 2002, 2002, 5058 : 417 - 424
  • [29] In-situ moire interferometry technique and its applications to microelectronic packages
    Shi, XQ
    Wang, ZP
    52ND ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, 2002 PROCEEDINGS, 2002, : 183 - 191
  • [30] A SIMPLE APPLICATION TECHNIQUE FOR PAPER CHROMATOGRAPHY
    NOVELLIE, L
    NATURE, 1952, 169 (4303) : 672 - 672