Verification and Repeatability Analysis for the In Situ Air Permeameter Test

被引:1
|
作者
White, David J. [1 ]
Vennapusa, Pavana [1 ,2 ]
Zhao, La [3 ]
机构
[1] Iowa State Univ, Ames, IA 50011 USA
[2] Iowa State Univ, Ames, IA 50010 USA
[3] Amer Engn Testing, St Paul, MN 55114 USA
来源
GEOTECHNICAL TESTING JOURNAL | 2014年 / 37卷 / 02期
关键词
air permeameter test; hydraulic conductivity; granular soils; drainage; pavement foundation; in situ testing;
D O I
10.1520/GTJ20130111
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The air permeameter test (APT) is a relatively new test device that uses gas pressure and flow measurements to rapidly determine (<15 s/test) in situ hydraulic conductivity of granular materials. The use of precision orifices for flow rate control allows for high precision at low pressures (i.e., <25 mm of water pressure). Application of low pressure during testing is necessary to simulate typical field drainage conditions for pavements, and rapid testing allows for characterizing the in situ variability of hydraulic conductivity. This paper describes details of the APT device components and system, test operations, verification assessments, and measurement error calculations from repeatability testing. The results of this paper provide information for APT users to assess the test device and measurements and information needed to develop testing guidelines and test standards.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] REPEATABILITY AND VERIFICATION OF ON-WAFER NOISE PARAMETER MEASUREMENTS
    FRASER, A
    STRID, E
    LEAKE, B
    BURCHAM, T
    MICROWAVE JOURNAL, 1988, 31 (11) : 172 - 176
  • [42] FIELD MEASUREMENT OF HYDRAULIC CONDUCTIVITY WITH A MODIFIED AIR-ENTRY PERMEAMETER
    TOPP, GC
    BINNS, MR
    CANADIAN JOURNAL OF SOIL SCIENCE, 1976, 56 (03) : 139 - 147
  • [43] Connection Repeatability of Waveguide Verification Standards for VNA System
    Shoaib, Nosherwan
    Sellone, Marco
    Brunetti, Luciano
    Oberto, Luca
    2016 URSI ASIA-PACIFIC RADIO SCIENCE CONFERENCE (URSI AP-RASC), 2016, : 485 - 488
  • [44] Reproducibility of the Conconi test: Test repeatability and observer variations
    Ballarin, E
    Sudhues, U
    Borsetto, C
    Casoni, I
    Grazzi, G
    Guglielmini, C
    Manfredini, F
    Mazzoni, G
    Conconi, F
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1996, 17 (07) : 520 - 524
  • [45] APPROXIMATE ANALYSIS OF THE BOREHOLE PERMEAMETER IN UNSATURATED SOIL
    PHILIP, JR
    WATER RESOURCES RESEARCH, 1985, 21 (07) : 1025 - 1033
  • [46] Statistical verification of the repeatability regimes at model of the bell furnace
    Stehlikova, Beata
    Durdan, Milan
    PROCEEDINGS OF THE 2016 17TH INTERNATIONAL CARPATHIAN CONTROL CONFERENCE (ICCC), 2016, : 697 - 701
  • [47] Analysis of measurement repeatability of optical signals emitted by electrical discharges in air insulation
    Fracz, Pawel
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (07): : 128 - 130
  • [48] Repeatability and verification of on-wafer noise parameter measurements
    Fraser, Arthur
    Strid, Eric
    Leake, Bernie
    Burcham, Terry
    Microwave journal, 1988, 31 (11):
  • [49] Field testing of a soil corer air permeameter (SCAP) in desert soils
    Chief, Karletta
    Ferre, Ty P. A.
    Nijssen, Bart
    VADOSE ZONE JOURNAL, 2006, 5 (04) : 1257 - 1263
  • [50] A source of systematic error in transient-flow air permeameter measurements
    Smith, JE
    Robin, MJL
    Elrick, DE
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1997, 61 (06) : 1563 - 1568