Investigation on pixellated CZT detectors coupled with a low power readout ASIC

被引:0
|
作者
Abbene, L. [1 ]
Del Sordo, S. [2 ]
Agnetta, G. [2 ]
Biondo, B. [2 ]
Caroli, E. [3 ]
Mangano, A. [2 ]
Russo, F. [2 ]
Stephen, J. B. [3 ]
Ventura, G. [3 ]
Carlino, A. [1 ]
Gerardi, G. [1 ]
Bertuccio, G. [4 ]
机构
[1] Univ Palermo, Dipartimento Fis & Tecnol Relat DIFTER, Viale Sci,Edificio 18, I-90128 Palermo, Italy
[2] IASF, INAF, I-90146 Palermo, Italy
[3] IASF, INAF, I-40129 Bologna, Italy
[4] Politecn Milan, Dipartimento Elettron & Informat, I-20133 Milan, Italy
关键词
CZT detectors; pixel detectors; single charge carrier sensing; small pixel effect; temperature dependency; SPECTROSCOPIC RESPONSE; ENERGY RESOLUTION; CDZNTE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, we investigated on the spectroscopic performances of two pixellated CZT detectors coupled with a custom low noise and low power readout ASIC. The detectors (10 x 10 x 1 mm(3) and 10 x 10 x 2 mm(3) single crystals) consist of an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 mu m BiCNIOS technology, is equipped with eight independent channels (preamplifier and shaper) characterized by a dynamic range from 10 keV to 100 keV, low power consumption (0.5 mW/channel) and low noise (150-500 electrons r.m.s.). The spectroscopic results point out the good energy resolution of both detectors at room temperature (5.8 % FWHM at 59.5 keV for the 1 mm, thick detector; 5.5 % FWHM at 59.5 keV for the 2 mm thick detector) and low tailing, confirming the single charge carrier sensing properties of the CZT detectors equipped with a pixellated anode layout. Temperature measurements show optimum performances of the system (detector and electronics) at T = 10 degrees C and performance degradations at lower temperatures. The detectors and the ASIC, designed by our collaboration, represent two small focal plane detector prototypes for hard X-ray telescopes operating in the 10-100 keV energy range.
引用
收藏
页码:5285 / +
页数:2
相关论文
共 50 条
  • [1] HEXITEC ASIC-a pixellated readout chip for CZT detectors
    Jones, Lawrence
    Seller, Paul
    Wilson, Matthew
    Hardie, Alec
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 34 - 37
  • [2] Anode readout for pixellated CZT detectors
    Narita, T
    Grindlay, JE
    Hong, J
    Niestemski, FC
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XIII, 2004, 5165 : 542 - 547
  • [3] A high counting-rate readout ASIC for CZT detectors
    Zhao, Siyao
    Gao, Chaosong
    Tian, Xiaojuan
    Tong, Qiaomu
    Xie, Lirong
    Yang, Ming
    Liu, Hongbang
    Sun, Xiangming
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [4] Development of an ASIC for the Readout of CZT/CdTe Radiation Detectors in Space
    Meier, Dirk
    Ramstad, Jan Erik
    Hasanbegovic, Amir
    Azman, Suleyman
    Talebi, Jahanzad
    Altan, Mehmet Akif
    Berge, Hans Kristian Otnes
    Pahlsson, Philip
    Gheorghe, Codin
    Johansen, Tor Magnus
    Maehlum, Gunnar
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [5] Development of a low noise readout ASIC for CZT detectors for gamma-ray spectroscopy applications
    Luo, J.
    Deng, Z.
    Wang, G.
    Li, H.
    Liu, Y.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [6] CZT strip detectors for imaging and spectroscopy: Collimated beam and ASIC readout experiments
    Kurczynski, P
    Krizmanic, JF
    Stahle, CM
    Parsons, A
    Palmer, DM
    Barbier, LM
    Bartlett, LM
    Barthelmy, SD
    Birsa, F
    Gehrels, N
    Odom, J
    Hanchak, C
    Shu, P
    Teegarden, BJ
    Tueller, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1011 - 1016
  • [7] CZT strip detectors for imaging and spectroscopy: Collimated beam and ASIC readout experiments
    Kurczynski, P
    Krizmanic, JF
    Stahle, CM
    Parsons, A
    Palmer, DM
    Bartlett, LM
    Barthelmy, SD
    Birsa, F
    Gehrels, N
    Odom, J
    Hanchak, C
    Star, P
    Teegarden, BJ
    Tueller, J
    Barbier, LM
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 670 - 675
  • [8] Development of a Multi-Energy Photon-Counting Readout ASIC for CZT Detectors
    Deng, Zhi
    Zhu, Xuezhou
    Chen, Yu
    Liu, Yinong
    Xing, Yuxiang
    Feng, Chuqing
    Wang, Guangqi
    Liu, Hui
    Wu, Sen
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [9] A Low Noise Readout ASIC for CdTe/CdZnTe Detectors
    Luo, Jie
    Deng, Zhi
    Liu, Yinong
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3804 - 3807
  • [10] Design of a Multichannel Low-Noise Front-End Readout ASIC Dedicated to CZT Detectors for PET Imaging
    Gao, W.
    Liu, H.
    Gan, B.
    Wei, T.
    Gao, D.
    Hu, Y.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (05) : 2532 - 2539