Automated image registration for FDOPA PET studies

被引:21
|
作者
Lin, KP [1 ]
Huang, SC [1 ]
Yu, DC [1 ]
Melega, W [1 ]
Barrio, JR [1 ]
Phelps, ME [1 ]
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DEPT MOL & MED PHARMACOL,LOS ANGELES,CA 90095
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1996年 / 41卷 / 12期
关键词
D O I
10.1088/0031-9155/41/12/014
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, various image registration methods are investigated for their suitability for registration of L-6-[18F]-fluoro-DOPA (FDOPA) PET images. Five different optimization criteria including sum of absolute difference (SAD), mean square difference (MSD), crosscorrelation coefficient (CC), standard deviation of pixel ratio (SDPR), and stochastic sign change (SSC) were implemented and Powell's algorithm was used to optimize the criteria. The optimization criteria were calculated either unidirectionally (i.e. only evaluating the criteria for comparing the resliced image 1 with the original image 2) or bidirectionally (i.e. averaging the criteria for comparing the resliced image 1 with the original image 2 and those for the sliced image 2 with the original image 1). Monkey FDOPA images taken at various known orientations were used to evaluate the accuracy of different methods. A set of human FDOPA dynamic images was used to investigate the ability of the methods for correcting subject movement. It was found that a large improvement in performance resulted when bidirectional rather than unidirectional criteria were used. Overall, the SAD, MSD and SDPR methods were found to be comparable in performance and were suitable for registering FDOPA images. The MSD method gave more adequate results for frame-to-frame image registration for correcting subject movement during a dynamic FDOPA study. The utility of the registration method is further demonstrated by registering FDOPA images in monkeys before and after amphetamine injection to reveal more clearly the changes in spatial distribution of FDOPA due to the drug intervention.
引用
收藏
页码:2775 / 2788
页数:14
相关论文
共 50 条
  • [31] AUTOMATED IMAGE REGISTRATION FOR DIGITAL SUBTRACTION ANGIOGRAPHY
    POTEL, MJ
    GUSTAFSON, DE
    MEDICAL PHYSICS, 1983, 10 (01) : 129 - 129
  • [32] Effect of Automated Image Registration on Radiologist Interpretation
    Bradley J. Erickson
    Jayawant Mandrekar
    Liqin Wang
    Julia W. Patriarche
    Brian J. Bartholmai
    Christropher P. Wood
    E. Paul Lindell
    Anne-Marie Sykes
    Gordon F. Harms
    Rebecca M. Lindell
    Katherine Andirole
    Journal of Digital Imaging, 2007, 20 : 105 - 113
  • [33] Estimating Target Registration Error for Automated Deformable Image Registration QA
    Sage, J.
    Boukerroui, D.
    Gooding, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E385 - E385
  • [34] Comparison of manual registration and automated registration in Matlab of AOSLO image sequences
    Bartsch, Dirk-Uwe G.
    Ofstad, Tyler
    Zawaydeh, Qais
    Jhingan, Mahima
    Freeman, William R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [35] Combined FDOPA and 30MFD PET studies in Parkinson's disease
    Dhawan, V
    Ishikawa, T
    Patlak, C
    Chaly, T
    Robeson, W
    Belakhlef, A
    Margouleff, C
    Mandel, F
    Eidelberg, D
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (02) : 209 - 216
  • [36] Automated model-based image registration for tactical image exploitation
    Trask, D
    Cannata, R
    Hackett, JK
    AUTOMATED GEO-SPATIAL IMAGE AND DATA EXPLOITATION, 2000, 4054 : 19 - 29
  • [37] Sex differences in pet FDOPA uptake
    Klein, EA
    Wu, JC
    BIOLOGICAL PSYCHIATRY, 1996, 39 (07) : 353 - 353
  • [38] Automated PET/CT cardiac registration for accurate attenuation correction
    Khurshid, Khawar
    Wu, Liyong
    Berger, Kevin
    McGough, Robert J.
    2006 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY, 2006, : 409 - 414
  • [39] FDOPA uptake in schizophrenia: A pet study
    Potkin, SG
    Wu, JC
    Klein, EA
    Khosla, N
    Najafi, A
    LaCasse, L
    BIOLOGICAL PSYCHIATRY, 1996, 39 (07) : 352 - 352
  • [40] Automated PET/CT Brain Registration for Accurate Attenuation Correction
    Khurshid, Khawar
    Berger, Kevin L.
    McGough, Robert J.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5805 - 5808