PREHOSPITAL COAGULATION MONITORING OF RESUSCITATION WITH POINT-OF-CARE DEVICES

被引:11
|
作者
Schott, Ulf [1 ,2 ]
机构
[1] Skane Univ Hosp, Dept Anaesthesia & Intens Care, Lund, Sweden
[2] Lund Univ, Lund, Sweden
来源
SHOCK | 2014年 / 41卷
关键词
Point of care; thromboelastography; lactate; hemoglobin; coagulation; trauma; PROTHROMBIN TIME; TRAUMA; FIBRINOGEN; HEMOGLOBIN; FLOW; HYPERFIBRINOLYSIS; HEMATOCRIT; HEMORRHAGE; DIAGNOSIS; ACIDOSIS;
D O I
10.1097/SHK.0000000000000108
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
A variety of point-of-care monitors for the measurement of hematocrit, hemoglobin, blood gas with electrolytes, and lactate can be used also in the prehospital setting for optimizing and individualizing trauma resuscitation. Point-of-care coagulation testing with activated prothrombin test, prothrombin test, and activated coagulation/clotting time tests is available for prehospital use. Although robust, battery driven, and easy to handle, many devices lack documentation for use in prehospital care. Some of the devices correspond poorly to corresponding laboratory analyses in acute trauma coagulopathy and at lower hematocrits. In trauma, viscoelastic tests such as rotational thromboelastometry and thromboelastography can rapidly detect acute trauma coagulopathy and give an overall dynamic picture of the hemostatic system and the interaction between its different components: coagulation activation, fibrin polymerization, fibrin platelet interactions within the clot, and fibrinolysis. Rotational thromboelastometry is shock resistant and has the potential to be used outside the hospital setting to guide individualized coagulation factor and blood component therapies. Sonoclot and Rheorox are two small viscoelastic instruments with one-channel options, but with less documentation. The point-of-care market for coagulation tests is quickly expanding, and new devices are introduced all the time. Still they should be better adopted to prehospital conditions, small, robust, battery charged, and rapid and use small sample volumes and whole blood.
引用
收藏
页码:26 / 29
页数:4
相关论文
共 50 条
  • [21] Prehospital point-of-care ultrasound use by the military
    Ward, David I.
    EMERGENCY MEDICINE AUSTRALASIA, 2007, 19 (03) : 282 - 282
  • [22] Prehospital point-of-care ultrasound: A transformative technology
    Amaral, Colton B.
    Ralston, Daniel C.
    Becker, Torben K.
    SAGE OPEN MEDICINE, 2020, 8
  • [23] Point-of-Care Diagnostics in Coagulation Management
    Sahli, Sebastian D.
    Rossler, Julian
    Tscholl, David W.
    Studt, Jan-Dirk
    Spahn, Donat R.
    Kaserer, Alexander
    SENSORS, 2020, 20 (15) : 1 - 21
  • [24] Point-of-care testing - Measurement of coagulation
    Hirsch, J
    Wendt, T
    Kuhly, P
    Schaffartzik, W
    ANAESTHESIA, 2001, 56 (08) : 760 - 763
  • [25] Point-of-Care Coagulation Diagnostics in the Neurosurgery
    Adam, Elisabeth Hannah
    Fuellenbach, Christoph
    Lindau, Simone
    Konczalla, Juergen
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2018, 53 (06): : 425 - 439
  • [26] Point-of-care testing of neonatal coagulation
    Tan, K
    Booth, D
    Newell, SJ
    Dear, PRF
    Hughes, C
    Richards, M
    CLINICAL AND LABORATORY HAEMATOLOGY, 2006, 28 (02): : 117 - 121
  • [27] Developing point-of-care devices
    不详
    VETERINARY RECORD, 2023, 192 (07) : 279 - 279
  • [28] Prehospital point-of-care monitoring and goal-directed therapy: Does it make a difference?
    Gaarder, Christine
    Holtan, Anders
    Naess, Paal Aksel
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2015, 78 : S60 - S64
  • [29] Intra-operative transfusion management: the usefulness of point-of-care coagulation monitoring
    Feltracco, Paolo
    Serra, Eugenio
    Ori, Carlo
    BLOOD TRANSFUSION, 2012, 10 (03) : 398 - 399
  • [30] Microfluidic Devices for HIV Diagnosis and Monitoring at Point-of-Care (POC) Settings
    Tharakan, Shebin
    Faqah, Omair
    Asghar, Waseem
    Ilyas, Azhar
    BIOSENSORS-BASEL, 2022, 12 (11):