Monte Carlo study and design of system for implementation of Rotational Total Skin Electron Irradiation technique

被引:0
|
作者
Ansari, M. [1 ]
Davani, F. Abbasi [2 ]
Rashti, M. Lamehi [1 ]
Monadi, Sh. [3 ]
Emami, H. [4 ]
机构
[1] AEOI, Nucl Sci & Technol Res Inst, Sch Phys & Accelerators, POB 14155-1339, Tehran, Iran
[2] Shahid Beheshti Univ, Dept Radiat Applicat, POB 1983963113, Tehran, Iran
[3] Seyed Alshohada Radiotherapy Ctr, Dept Radiotherapy, POB 8184917911, Esfahan, Iran
[4] Isfahan Univ Med Sci, Sch Med, Dept Radiotherapy & Oncol, POB 8184917911, Esfahan, Iran
来源
关键词
Algorithms and Software for radiotherapy; Instrumentation for gamma-electron therapy; Radiotherapy concepts; DOSIMETRY; THERAPY; BEAM; SIMULATION;
D O I
10.1088/1748-0221/13/05/P05029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Depending on the linear accelerator (Linac) type, bunker size, room dimensions and dosimetry equipment, the design of instruments for appropriate set up and implementation of TSEI in different radiation therapy centers varies. The studies which have been done in this article provide an introduction to the implementing of this method for the first time in Iran and its results can be used for the centers with similar specifications in the world. This article determined the electron beam characteristic of TSEI for the only electron accelerator, located at the radiation center of the Seyed Alshohada Hospital of Isfahan (NEPTUN 10PC), by performing Monte Carlo simulations and using EGSnrc-based codes (BEAMnrc and DOSXYZnrc). For the best uniformity of the vertical profile, the optimal angle of gantry was defined at SSD = 350 cm. The effect of the degrader plane that is located at a distance of 20 cm from the patient surface, was evaluated on the amount of energy reduction of the beam, the opening of the electron beam field and the homogeneity of the dose distribution. The transversal dose distribution from the whole treatment with Stanford technique (six dual fields) and Rotational technique was simulated in a CT-based anthropomorphic phantom. Also, the percentage depth dose in the head, neck, thorax, abdomen and legs was obtained for both methods. The simulation results show that the 20 degrees angle between the horizontal and the beam central axis is optimal in order to provide the best vertical dose uniformity. The mean energy decreases from 6.1 MeV (the exit window) to 3 MeV (the treatment surface) by placing a degrader with 0.8 cm thickness in front of the treatment plane. FWHM of the angular distribution of the electron beam increased from 15 degrees at SSD = 100 cm to more than 30 degrees on the treatment surface by traversing the PMMA degrader. The MC calculated percentage depth dose curves in different organs of anthropomorphic phantom for RTSEI indicates that the depth of maximum dose is on the surface of the phantom and Isodose curve of 80% is formed at a depth less than 4 mm. the results also show, with the degrader plane in front of the patient, the degree of homogeneity of the dose distribution for both Stanford and rotational techniques is the same.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Commissioning of Rotational Total Skin Electron Irradiation on Trilogy Machine
    Zhang, Q.
    Chan, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [22] Validation of Total Skin Irradiation Using Two Monte Carlo Systems
    Tseng, W.
    Li, R.
    Wu, Q.
    Sawkey, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E262 - E262
  • [23] A Monte Carlo Study of Patient Dose Distributions Between Stanford Six-Field and Rotational Techniques in Total Skin Electron Therapy
    Ding, G.
    Chen, Z.
    Zhong, W.
    Zhu, T.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [24] Total Skin Electron Irradiation (TSEI) Using Rotational Technique for Cutaneous T-Cell Lymphoma
    Heumann, T. R.
    Esiashvili, N.
    Parker, S.
    Switchenko, J. M.
    Lechowicz, M.
    Flowers, C.
    Khan, M. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S680 - S681
  • [25] Investigation of Effect of Filter On the Total Skin Irradiation Using Monte Carlo Simulation
    Tseng, W.
    Li, R.
    Wu, Q.
    MEDICAL PHYSICS, 2019, 46 (06) : E230 - E230
  • [26] Investigation of Effect of Filter on the Total Skin Irradiation Using Monte Carlo Simulation
    Wu, Q.
    Tseng, W.
    Li, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E688 - E688
  • [27] CALCULATION OF SURFACE DOSE IN ROTATIONAL TOTAL SKIN ELECTRON-IRRADIATION
    PLA, C
    HEESE, R
    PLA, M
    PODGORSAK, EB
    MEDICAL PHYSICS, 1984, 11 (03) : 400 - 400
  • [28] Dual-Fields Rotational Total Skin Electron Irradiation/therapy
    Xu, M.
    Sethi, A.
    Glasgow, G. P.
    Gao, M.
    Ke, Y.
    Rusu, I.
    Roeske, J.
    Chi, A.
    Garza, R.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [29] CALCULATION OF SURFACE DOSE IN ROTATIONAL TOTAL SKIN ELECTRON-IRRADIATION
    PLA, C
    HEESE, R
    PLA, M
    PODGORSAK, EB
    MEDICAL PHYSICS, 1984, 11 (04) : 539 - 546
  • [30] Commissioning Total Skin Electron Therapy and Monte Carlo Verification of Patient Skin Dose
    Nie, W.
    Yeo, I.
    Huynh, K.
    Tong, S.
    Fan, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E833 - E833