Finite element model-based evaluation of tissue stress variations to fabricate corrective orthosis in feet with neutral subtalar joint

被引:4
|
作者
Paul, Sathish [1 ]
Vijayakumar, Rekha [2 ]
Mathew, Lazar [3 ]
Sivarasu, Sudesh [4 ]
机构
[1] SIHR & LC Hosp, Vellore, Tamil Nadu, India
[2] VIT Univ, Vellore, Tamil Nadu, India
[3] PSG Inst Adv Studies, Coimbatore, Tamil Nadu, India
[4] Univ Cape Town, Fac Hlth Sci, ZA-7925 Cape Town, South Africa
关键词
Biomechanics of prosthetic/orthotic devices; Computer Aided Designing-Computer Aided Manufacturing (CAD-CAM); prosthetic design; prosthetics and orthotics in developing countries; FLEXIBLE FLAT FOOT; GAIT;
D O I
10.1177/0309364616631344
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The subtalar joint position during static stance is a crucial determinant of the peak plantar pressures and forms ideal reference point for any intervention in foot-related problems for leprosy-affected patients. Objectives: The study pursued the hypothesis through a three-dimensional model that stress will be minimal in the distal joints of the foot when the subtalar joint is in neutral static stance position. Study design: Finite element model. Methods: The computed tomography images of the feet for five patients suffering from Hansen's disease having no muscle weakness and joint restriction were acquired. The gray intensities corresponding to the bones of the foot from the computed tomography images were three-dimensionally reconstructed. The three-dimensional model of the human foot, incorporating the realistic geometry, and the material properties of the hard tissues were then analyzed using a finite element solver for the stress distribution on bones of the foot. Results: The results demonstrate that the position of the calcaneum in the static stance position does contribute to the varying stress in the foot. Conclusion: The stresses in the bones of the foot are minimal while the subtalar is in neutral position; this position will be suitable for foot orthotic fabrication.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 11 条
  • [1] Simplified finite model based evaluation of tissue stress distribution on anesthetic feet of Leprosy patients for 3 dimensional orthosis fabrication
    Sathish K Paul
    Sudesh Sivarasu
    Journal of Foot and Ankle Research, 7 (Suppl 1)
  • [2] Biomechanical evaluation of acromioclavicular joint reconstructions using a 3-dimensional model based on the finite element method
    Menegaz, Gabriela Lima
    Gomide, Leandro Cardoso
    Araujo, Cleudmar Amaral
    CLINICAL BIOMECHANICS, 2019, 70 : 170 - 176
  • [3] The study on evaluation model for prefabricated HV stress cone of cable terminations weakness based on finite element
    Liu Gang
    Liu Yigang
    Wang Chao
    Yi Zepei
    CONFERENCE RECORD OF THE 2006 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2006, : 486 - +
  • [4] Establishment of a finite element model based on craniofacial soft tissue thickness measurements and stress analysis of medical goggles
    Yang, Wenxiu
    Wang, Haining
    He, Renke
    ERGONOMICS, 2022, 65 (02) : 305 - 326
  • [5] Finite Element Model-Based Weight-Over Process Philosophy for Bridge Loading Capacity Evaluation and Rating Factor Estimation
    Karimpour, Ali
    Rahmatalla, Salam
    Bolboli Ghadikolaee, Hossein
    ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [6] A Surrogate Model Based on a Finite Element Model of Abdomen for Real-Time Visualisation of Tissue Stress during Physical Examination Training
    Leong, Florence
    Lai, Chow Yin
    Khosroshahi, Siamak Farajzadeh
    He, Liang
    de Lusignan, Simon
    Nanayakkara, Thrishantha
    Ghajari, Mazdak
    BIOENGINEERING-BASEL, 2022, 9 (11):
  • [7] A Discrete-Finite Element Analysis Model Based on Almen Intensity Test for Evaluation of Real Shot Peening Residual Stress
    Wang, Chengan
    Park, Yujin
    Kim, Taehyung
    MATERIALS, 2023, 16 (15)
  • [8] Impact of pore defects on laser additive manufacturing of Inconel 718 alloy based on a novel finite element model: Thermal and stress evaluation
    Meng, Guiru
    Zhang, Jingdong
    Li, Jiachen
    Jiang, Zongze
    Gong, Yadong
    Zhao, Jibin
    OPTICS AND LASER TECHNOLOGY, 2023, 167
  • [9] Stress Distribution of the Tibiofemoral Joint in a Healthy Versus Osteoarthritis Knee Model Using Image-Based Three-Dimensional Finite Element Analysis
    Kulchamai Thienkarochanakul
    Akbar A. Javadi
    Mohammad Akrami
    Joseph Robert Charnley
    Abdelmalek Benattayallah
    Journal of Medical and Biological Engineering, 2020, 40 : 409 - 418
  • [10] Stress Distribution of the Tibiofemoral Joint in a Healthy Versus Osteoarthritis Knee Model Using Image-Based Three-Dimensional Finite Element Analysis
    Thienkarochanakul, Kulchamai
    Javadi, Akbar A.
    Akrami, Mohammad
    Charnley, Joseph Robert
    Benattayallah, Abdelmalek
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2020, 40 (03) : 409 - 418