GlowFit - a new tool for thermoluminescence glow-curve deconvolution

被引:238
|
作者
Puchalska, M. [1 ]
Bilski, P. [1 ]
机构
[1] Polish Acad Sci, H Niewodniczanski Inst Nucl Phys, PL-31342 Krakow, Poland
关键词
thermoluminescence; first-order kinetic; deconvolution; LiF; Levenberg-Marquardt method;
D O I
10.1016/j.radmeas.2006.03.008
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A new computer program, GlowFit, for deconvoluting first-order kinetics thermoluminescence (TL) glow-curves has been developed. A non-linear function describing a single glow-peak is fitted to experimental points using the least squares Levenberg-Marquardt method. The main advantage of GlowFit is the ability to resolve complex TL glow-curves consisting of strongly overlapping peaks, as those observed in heavily-doped LiF:Mg,Ti (MTT) detectors. This resolution is achieved mainly by setting constraints or by fixing selected parameters. The initial values of the fitted parameters are placed in the so-called pattern files. GlowFit is a Microsoft Windows-operated user-friendly program. The graphic interface enables easy intuitive manipulation of glow-peaks, at the initial stage (parameter initialization) and at the final stage (manual adjustment) of fitting peak parameters to the glow-curves. The program is freely downloadable from the web site http://www.ifj.edu.pl/dept/no5/nz58/deconvolution.htm (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:659 / 664
页数:6
相关论文
共 50 条
  • [31] Glow-curve de-convolution analysis of TL glow-curve from constant temperature hot gas TLD readers
    Kitis, G.
    Carinou, E.
    Askounis, P.
    RADIATION MEASUREMENTS, 2012, 47 (04) : 258 - 265
  • [32] Thermoluminescence glow curve deconvolution functions by continued fractions for different orders of kinetics
    Flores-Llamas, H.
    Gutierrez-Tapia, C.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2013, 168 (03): : 163 - 175
  • [33] Nanostructured TLDs: Studying the impact of crystalline size on the Thermoluminescence glow-curve shape and electron trapping parameters
    Tsoutsoumanos, E.
    Saleh, M.
    Konstantinidis, P. G.
    Altunal, V.
    Sahare, P. D.
    Yengigil, Z.
    Karakasidis, T.
    Kitis, G.
    Polymeris, G. S.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [34] Computerised glow curve analysis: A tool for routine thermoluminescence dosimetry
    Delgado, A
    Ros, JMG
    RADIATION PROTECTION DOSIMETRY, 2001, 96 (1-3) : 127 - 132
  • [35] A new method for the numerical analysis of thermoluminescence glow curve
    Chung, K. S.
    Choe, H. S.
    Lee, J. I.
    Kim, J. L.
    RADIATION MEASUREMENTS, 2007, 42 (4-5) : 731 - 734
  • [36] On the analysis of thermoluminescence glow curve
    Prakash, J
    Prasad, D
    Rai, SK
    Singh, PK
    NATIONAL ACADEMY SCIENCE LETTERS-INDIA, 2001, 24 (5-12): : 107 - 111
  • [37] ANALYSIS OF THERMOLUMINESCENCE KINETICS OF CAF2(TM) PEAKS WITH GLOW CURVE DECONVOLUTION
    BACCI, C
    BERNARDINI, P
    DIDOMENICO, A
    FURETTA, C
    RISPOLI, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 286 (1-2): : 295 - 300
  • [38] Thermoluminescence glow curve deconvolution and its statistical analysis using the flexibility of spreadsheet programs
    van Dijk, J. W. E.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 332 - 338
  • [39] A new approach to the analysis of thermoluminescence glow-curve of TLD-600 dosimeters following Am-241 alpha particles irradiation
    Sadek, A. M.
    Hassan, M. M.
    Esmat, E.
    Eissa, H. M.
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (03) : 260 - 271
  • [40] GLOW-CURVE ANALYSIS FOR VERIFICATION OF DOSE IN LIF CHIPS
    HOOTS, SS