Behaviours of stiffened concrete-filled thin-walled square steel tubular stub columns after non-uniform fire exposure

被引:20
|
作者
Lyu, Xuetao [1 ,3 ]
Zhang, Tong [2 ]
Liu, Faqi [3 ,4 ]
Liu, Yujie [2 ]
机构
[1] Foshan Univ, Sch Transportat Civil Engn & Architecture, Adv & Sustainable Infrastruct Mat Grp, Foshan 528000, Peoples R China
[2] Liaoning Tech Univ, Sch Civil Engn, Fuxin 123000, Peoples R China
[3] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[4] Harbin Inst Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Minist Ind & Informat Technol, Harbin 150090, Peoples R China
基金
中国国家自然科学基金;
关键词
Stiffened concrete-filled thin-walled squared  steel tubular column; Post-fire; Residual capacity; Test; Numerical simulation; COMPRESSIVE BEHAVIOR; TUBE COLUMNS; RESISTANCE; STRENGTH; DESIGN; PERFORMANCE; HOLLOW; PLATES;
D O I
10.1016/j.jcsr.2021.107031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Behaviours of stiffened concrete-filled thin-walled square steel tubular stub columns after non-uniform fire exposure was studied experimentally and numerically. The considered parameters were heating time, fire boundaries and stiffeners. The failure modes, temperatures in specimens, axial load-displacement curves and strains in steel tubes were measured and discussed. The test results show that all the specimens exhibited waist drum type failures and the concrete becomes more brittle and suffers more severe damage with increased fire exposure sides. The residual bearing capacity, compressive stiffness and ductility index decrease with an increase in heating time and fire exposure sides. Stiffeners can effectively improve the ductility of thin-walled concretefilled square steel tubular stub columns after fire exposure. A finite element (FE) model was developed using the sequentially coupled thermal-stress analysis method and was validated against tests in this study. Parametric analysis was conducted to identify the influences of key parameters on load-bearing capacity. The FE results show that fire boundary exposure has a significant influence on the residual bearing capacity. The more sides exposed to fire, the lower is the residual bearing capacity. The yield strength and diameter of the stiffeners have no obvious influence on the residual bearing capacity of the specimen. Finally, simplified methods were proposed for predicting the ultimate bearing capacity of stiffened concrete-filled thin-walled square steel tubular stub columns after uniform and non-uniform fire exposure.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Axial Compressive Behavior of Thin-Walled Concrete-Filled Double-Skin Steel Tubular Stub Columns with Connecting Strips
    Shen, Le
    Ding, Miao
    Feng, Chen
    Alqawzai, Shagea
    Elchalakani, Mohamed
    Yang, Bo
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (02)
  • [42] Degradation of Axial Ultimate Load-Bearing Capacity of Circular Thin-Walled Concrete-Filled Steel Tubular Stub Columns after Corrosion
    Zhang, Fengjie
    Xia, Junwu
    Li, Guo
    Guo, Zhen
    Chang, Hongfei
    Wang, Kejin
    MATERIALS, 2020, 13 (03)
  • [43] Experimental study and finite element analysis of square stub columns with tensile sheets of concrete-filled thin-walled steel tube
    Chen, Yong
    Zhang, Yaochun
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2006, 27 (05): : 23 - 29
  • [44] Dynamic behaviors of concrete-filled steel tubular stub columns after exposure to high temperature
    Ren, Xiao-Hu
    Huo, Jing-Si
    Chen, Bai-Sheng
    Zhendong yu Chongji/Journal of Vibration and Shock, 2011, 30 (11): : 67 - 73
  • [45] Local buckling of steel plates in concrete-filled thin-walled steel tubular beam-columns
    Liang, Qing Quan
    Uy, Brian
    Liew, J. Y. Richard
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (03) : 396 - 405
  • [46] Analysis and Design of Elliptical Concrete-Filled Thin-Walled Steel Stub Columns Under Axial Compression
    Wang, Jingfeng
    Shen, Qihan
    Jiang, Han
    Pan, Xuebei
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2018, 18 (02) : 365 - 380
  • [47] Analysis and Design of Elliptical Concrete-Filled Thin-Walled Steel Stub Columns Under Axial Compression
    Jingfeng Wang
    Qihan Shen
    Han Jiang
    Xuebei Pan
    International Journal of Steel Structures, 2018, 18 : 365 - 380
  • [48] Seismic Tests on Square Thin-Walled Steel Tubular Columns Filled with Demolished Concrete Lumps
    Wu, Bo
    Zhao, Xinyu
    Zhang, Jinsuo
    Liu, Qiongxiang
    NOVEL AND NON-CONVENTIONAL MATERIALS AND TECHNOLOGIES FOR SUSTAINABILITY, 2012, 517 : 958 - +
  • [49] Behavior of CFRP retrofitted concrete filled steel tubular stub columns after exposure to fire
    Tao, Zhong
    Wang, Ling-Ling
    Han, Lin-Hai
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 947 - 953
  • [50] Residual Strength of Steel-Reinforced Concrete-Filled Square Steel Tubular (SRCFST) Stub Columns After Exposure to ISO-834 Standard Fire
    Meng, Fanqin
    Zhu, Mei-chun
    Mou, Ben
    He, Baojie
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2019, 19 (03) : 850 - 866