Behaviours of stiffened concrete-filled thin-walled square steel tubular stub columns after non-uniform fire exposure

被引:20
|
作者
Lyu, Xuetao [1 ,3 ]
Zhang, Tong [2 ]
Liu, Faqi [3 ,4 ]
Liu, Yujie [2 ]
机构
[1] Foshan Univ, Sch Transportat Civil Engn & Architecture, Adv & Sustainable Infrastruct Mat Grp, Foshan 528000, Peoples R China
[2] Liaoning Tech Univ, Sch Civil Engn, Fuxin 123000, Peoples R China
[3] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[4] Harbin Inst Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Minist Ind & Informat Technol, Harbin 150090, Peoples R China
基金
中国国家自然科学基金;
关键词
Stiffened concrete-filled thin-walled squared  steel tubular column; Post-fire; Residual capacity; Test; Numerical simulation; COMPRESSIVE BEHAVIOR; TUBE COLUMNS; RESISTANCE; STRENGTH; DESIGN; PERFORMANCE; HOLLOW; PLATES;
D O I
10.1016/j.jcsr.2021.107031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Behaviours of stiffened concrete-filled thin-walled square steel tubular stub columns after non-uniform fire exposure was studied experimentally and numerically. The considered parameters were heating time, fire boundaries and stiffeners. The failure modes, temperatures in specimens, axial load-displacement curves and strains in steel tubes were measured and discussed. The test results show that all the specimens exhibited waist drum type failures and the concrete becomes more brittle and suffers more severe damage with increased fire exposure sides. The residual bearing capacity, compressive stiffness and ductility index decrease with an increase in heating time and fire exposure sides. Stiffeners can effectively improve the ductility of thin-walled concretefilled square steel tubular stub columns after fire exposure. A finite element (FE) model was developed using the sequentially coupled thermal-stress analysis method and was validated against tests in this study. Parametric analysis was conducted to identify the influences of key parameters on load-bearing capacity. The FE results show that fire boundary exposure has a significant influence on the residual bearing capacity. The more sides exposed to fire, the lower is the residual bearing capacity. The yield strength and diameter of the stiffeners have no obvious influence on the residual bearing capacity of the specimen. Finally, simplified methods were proposed for predicting the ultimate bearing capacity of stiffened concrete-filled thin-walled square steel tubular stub columns after uniform and non-uniform fire exposure.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Behaviour of T-shaped stiffened concrete-filled steel tubular stub columns after uniform and non-uniform fire exposure
    Lyu, Xuetao
    Li, Ying
    Wang, Weiwei
    Liu, Faqi
    Xu, Yang
    ADVANCES IN STRUCTURAL ENGINEERING, 2024, 27 (01) : 72 - 84
  • [2] Shear strength of stiffened square thin-walled concrete-filled steel tubular columns
    Zhou, Zheng
    Zhou, Xuhong
    Yan, Biao
    Gan, Dan
    JOURNAL OF BUILDING ENGINEERING, 2022, 58
  • [3] ANALYSIS OF CONCRETE-FILLED SQUARE THIN-WALLED STEEL TUBULAR STUB COLUMNS WITH STEEL BAR STIFFENERS
    Xu, Cheng-Xiang
    Chen, Jian-Quan
    Xu, Shu-Zhen
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 498 - 502
  • [4] Behavior of Corroded Thin-Walled Concrete-Filled Steel Tubular Stub Columns
    Xue, Wen
    Chen, Ju
    Xie, Fang
    Ye, Changhu
    Liu, Chengbin
    BUILDINGS, 2022, 12 (04)
  • [5] Experimental. behaviour of concrete-filled stiffened thin-walled steel tubular columns
    Tao, Zhong
    Han, Lin-Hai
    Wang, Dong-Ye
    THIN-WALLED STRUCTURES, 2007, 45 (05) : 517 - 527
  • [6] Calculation on stiffened concrete-filled thin-walled hollow steel structural (HSS) stub columns
    Wang, Zhi-Bin
    Duan, Hua-Fei
    Tao, Zhong
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1443 - 1447
  • [7] Behavior of cross-shaped stiffened concrete-filled steel tubular stub columns after fire exposure
    Wang, Weiwei
    Lyu, Xuetao
    Liu, Xin
    Zheng, Jun
    Gao, Han
    Yu, Yang
    STRUCTURES, 2024, 68
  • [8] Performance of square steel-reinforced concrete-filled steel tubular columns subject to non-uniform fire
    Meng, Fan-Qin
    Zhu, Mei-Chun
    Clifton, G. Charles
    Ukanwa, Kingsley U.
    Lim, James B. P.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 166
  • [9] Hysteretic behavior of square concrete-filled thin-walled steel tubular columns with ribs
    School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
    Dongnan Daxue Xuebao, 2007, 1 (100-106):
  • [10] Experimental behaviour of stiffened concrete-filled thin-walled hollow steel structural (HSS) stub columns
    Tao, Z
    Han, LH
    Wang, ZB
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (07) : 962 - 983