Probing the absolute neutrino mass scale with 163Ho: The HOLMES project

被引:1
|
作者
De Gerone, M. [1 ]
Alpert, B. [2 ]
Becker, D. [2 ]
Bennett, D. [2 ]
Biasotti, M. [1 ,3 ]
Ceriale, V [1 ,3 ]
Dressler, R. [4 ]
Faverzani, M. [5 ,6 ]
Ferri, E. [5 ]
Fowler, J. [2 ]
Gallucci, G. [1 ]
Gard, J. [2 ]
Gatti, F. [1 ,3 ]
Giachero, A. [5 ,6 ]
J-Hays-Wehle [2 ,5 ]
Heinitz, S. [4 ]
Hilton, G. [2 ]
Koester, U. [7 ]
Lusignoli, M. [8 ,9 ]
Mates, J. [2 ]
Nucciotti, A. [5 ,6 ]
Nisi, S. [10 ]
Orlando, A. [5 ]
Pessina, G. [5 ]
Puiu, A. [5 ,6 ]
Ragazzi, S. [5 ]
Reintsema, C. [2 ]
Ribeiro Gomes, M. [11 ]
Schmidt, D. [2 ]
Schumann, D. [4 ]
Swetz, D. [2 ]
Ullom, J. [2 ]
Vale, L. [2 ]
机构
[1] Ist Nazl Fis Nucl, Sez Genova, Genoa, Italy
[2] NIST, Boulder, CO USA
[3] Univ Genoa, Dipartimento Fis, Genoa, Italy
[4] Paul Scherrer Inst, Villigen, Switzerland
[5] Ist Nazl Fis Nucl, Sez Milano Bicocca, Milan, Italy
[6] Univ Milano Bicocca, Dipartimento Fis, Milan, Italy
[7] Inst Laue Langevin, Grenoble, France
[8] Ist Nazl Fis Nucl, Sez Roma 1, I-1 Rome, Italy
[9] Univ Roma La Sapienza, Dipartimento Fis, Rome, Italy
[10] Ist Nazl Fis Nucl, Lab Nazl Gran Sasso, Assergi, Italy
[11] Univ Lisbon, Multidisciplinary Ctr Astrophys, Lisbon, Portugal
基金
欧洲研究理事会;
关键词
Neutrino mass measurement; Electron capture; Holmium; Transition edge sensors;
D O I
10.1016/j.nima.2018.10.108
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The HOLMES project aims to directly measure the nu mass down to the eV scale using the electron capture decay (EC) of Ho-163. It will perform a precise calorimetric measurement of the end-point of the Ho energy spectrum looking for the deformation caused by a finite nu mass. The choice of Ho-163 as source is driven by the very low Q-value of the EC reaction, which allows for high sensitivity with low activities (O(10(2))Bq/detector), thus reducing the pile-up probability. A large array made by thousands of transition edge sensors based micro-calorimeters will be used. The calorimetric approach eliminates systematic uncertainties arising from the use of an external beta source, and minimizes the effect of the atomic de-excitation process. The commissioning of the first implanted sub-array is scheduled for the end of 2018. It will provide useful data about the EC decay of Ho-163 together with a first limit on nu mass.
引用
收藏
页码:252 / 253
页数:2
相关论文
共 50 条
  • [1] Probing the absolute neutrino mass scale with 163Ho: the HOLMES project
    De Gerone, M.
    NUCLEAR AND PARTICLE PHYSICS PROCEEDINGS, 2015, 265 : 77 - 79
  • [2] Determination of the neutrino mass in 163Ho
    Faessler, Amand
    CONFERENCE ON NEUTRINO AND NUCLEAR PHYSICS (CNNP2017), 2018, 1056
  • [3] Direct measurement of neutrino mass using 163Ho
    Gastaldo, L
    NEUTRINO PHYSICS, 2003, 152 : 251 - 255
  • [4] 163Ho distillation and implantation for the HOLMES experiment
    De Gerone, M.
    Biasotti, M.
    Ceriale, V
    Dressler, R.
    Faverzani, M.
    Ferri, E.
    Gallucci, G.
    Gatti, F.
    Giachero, A.
    Heinitz, S.
    Manfrinetti, P.
    Nucciotti, A.
    Orlando, A.
    Provino, A.
    Puiu, A.
    Schumann, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 220 - 221
  • [5] 163Ho Distillation and Implantation for HOLMES Experiment
    Gallucci, G.
    Biasotti, M.
    Ceriale, V.
    De Gerone, M.
    Faverzani, M.
    Ferri, E.
    Gatti, F.
    Giachero, A.
    Manfrinetti, P.
    Nucciotti, A.
    Orlando, A.
    Provino, A.
    Puiu, A.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2019, 194 (5-6) : 453 - 459
  • [6] Microfabrication of Transition-Edge Sensor Arrays of Microcalorimeters with 163Ho for Direct Neutrino Mass Measurements with HOLMES
    Orlando, A.
    Ceriale, V.
    Ceruti, G.
    De Gerone, M.
    Faverzani, M.
    Ferri, E.
    Gallucci, G.
    Giachero, A.
    Nucciotti, A.
    Puiu, A.
    Schmidt, D.
    Swetz, D.
    Ullom, J.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2018, 193 (5-6) : 771 - 776
  • [7] HOLMES The electron capture decay of 163Ho to measure the electron neutrino mass with sub-eV sensitivity
    Alpert, B.
    Balata, M.
    Bennett, D.
    Biasotti, M.
    Boragno, C.
    Brofferio, C.
    Ceriale, V.
    Corsini, D.
    Day, P. K.
    De Gerone, M.
    Dressler, R.
    Faverzani, M.
    Ferri, E.
    Fowler, J.
    Gatti, F.
    Giachero, A.
    Hays-Wehle, J.
    Heinitz, S.
    Hilton, G.
    Koester, U.
    Lusignoli, M.
    Maino, M.
    Mates, J.
    Nisi, S.
    Nizzolo, R.
    Nucciotti, A.
    Pessina, G.
    Pizzigoni, G.
    Puiu, A.
    Ragazzi, S.
    Reintsema, C.
    Ribeiro Gomes, M.
    Schmidt, D.
    Schumann, D.
    Sisti, M.
    Swetz, D.
    Terranova, F.
    Ullom, J.
    EUROPEAN PHYSICAL JOURNAL C, 2015, 75 (03): : 1 - 11
  • [8] Microfabrication of Transition-Edge Sensor Arrays of Microcalorimeters with 163Ho for Direct Neutrino Mass Measurements with HOLMES
    A. Orlando
    V. Ceriale
    G. Ceruti
    M. De Gerone
    M. Faverzani
    E. Ferri
    G. Gallucci
    A. Giachero
    A. Nucciotti
    A. Puiu
    D. Schmidt
    D. Swetz
    J. Ullom
    Journal of Low Temperature Physics, 2018, 193 : 771 - 776
  • [9] Statistical sensitivity of 163Ho electron capture neutrino mass experiments
    Nucciotti, Angelo