Wearable Inertial Sensors for Gait Analysis in Adults with Osteoarthritis-A Scoping Review

被引:49
|
作者
Kobsar, Dylan [1 ]
Masood, Zaryan [1 ]
Khan, Heba [1 ]
Khalil, Noha [1 ]
Kiwan, Marium Yossri [1 ]
Ridd, Sarah [2 ]
Tobis, Matthew [1 ]
机构
[1] McMaster Univ, Fac Sci, Dept Kinesiol, Hamilton, ON L8S 4L8, Canada
[2] McMaster Univ, Dept Psychol Neurosci & Behav, Fac Sci, Hamilton, ON L8S 4L8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
inertial sensors; wearable technology; osteoarthritis; gait; biomechanics; walking; review; TOTAL KNEE ARTHROPLASTY; TOTAL ANKLE REPLACEMENT; LOWER-LIMB KINEMATICS; ADDUCTION MOMENT; MOUNTED ACCELEROMETERS; CLINICAL-EVALUATION; HIP OSTEOARTHRITIS; FLEXION MOMENTS; OLDER-ADULTS; BASE-LINE;
D O I
10.3390/s20247143
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Our objective was to conduct a scoping review which summarizes the growing body of literature using wearable inertial sensors for gait analysis in lower limb osteoarthritis. We searched six databases using predetermined search terms which highlighted the broad areas of inertial sensors, gait, and osteoarthritis. Two authors independently conducted title and abstract reviews, followed by two authors independently completing full-text screenings. Study quality was also assessed by two independent raters and data were extracted by one reviewer in areas such as study design, osteoarthritis sample, protocols, and inertial sensor outcomes. A total of 72 articles were included, which studied the gait of 2159 adults with osteoarthritis (OA) using inertial sensors. The most common location of OA studied was the knee (n = 46), followed by the hip (n = 22), and the ankle (n = 7). The back (n = 41) and the shank (n = 40) were the most common placements for inertial sensors. The three most prevalent biomechanical outcomes studied were: mean spatiotemporal parameters (n = 45), segment or joint angles (n = 33), and linear acceleration magnitudes (n = 22). Our findings demonstrate exceptional growth in this field in the last 5 years. Nevertheless, there remains a need for more longitudinal study designs, patient-specific models, free-living assessments, and a push for "Code Reuse" to maximize the unique capabilities of these devices and ultimately improve how we diagnose and treat this debilitating disease.
引用
收藏
页码:1 / 24
页数:24
相关论文
共 50 条
  • [31] A systematic review of gait analysis methods based on inertial sensors and adaptive algorithms
    Caldas, Rafael
    Mundt, Marion
    Potthast, Wolfgang
    de Lima Neto, Fernando Buarque
    Markert, Bernd
    GAIT & POSTURE, 2017, 57 : 204 - 210
  • [32] Inertial Sensors for Hip Arthroplasty Rehabilitation: A Scoping Review
    Acosta-Vargas, Patricia
    Flor, Omar
    Salvador-Acosta, Belen
    Suarez-Carreno, Franyelit
    Santorum, Marco
    Solorzano, Santiago
    Salvador-Ullauri, Luis
    SENSORS, 2023, 23 (11)
  • [33] Wearable Inertial Devices in Duchenne Muscular Dystrophy: A Scoping Review
    Panero, Elisa
    D'Alessandro, Rossella
    Cavallina, Ilaria
    Davico, Chiara
    Mongini, Tiziana
    Gastaldi, Laura
    Ricci, Federica
    APPLIED SCIENCES-BASEL, 2023, 13 (03):
  • [34] Gait asymmetrical evaluation of lower limb amputees using wearable inertial sensors
    Maqbool, Hafiz Farhan
    Mahmood, Imran
    Ali, Ahmad
    Iqbal, Nadeem
    Seong, Jin-Taek
    Dehghani-Sanij, Abbas Ali
    Alaziz, Sundas Naji
    Awad, Mohammed Ibrahim
    HELIYON, 2024, 10 (12)
  • [35] Wearable Sensors for Healthcare of Industrial Workers: A Scoping Review
    Moon, Juhyun
    Ju, Byeong-Kwon
    ELECTRONICS, 2024, 13 (19)
  • [36] Feasibility of using wearable inertial sensors for assessing gait changes after total knee arthroplasty: a systematic review and meta-analysis
    Martino Cinnera, Alex
    Morone, Giovanni
    Marrano, Serena
    Vannozzi, Giuseppe
    Picerno, Pietro
    MINERVA ORTHOPEDICS, 2021, 72 (05): : 498 - 508
  • [37] Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review
    Lee, Roger
    James, Carole
    Edwards, Suzi
    Skinner, Geoff
    Young, Jodi L.
    Snodgrass, Suzanne J.
    SENSORS, 2021, 21 (19)
  • [38] Inertial sensors versus standard systems in gait analysis: a systematic review and meta-analysis
    Petraglia, Federica
    Scarcella, Luca
    Pedrazzi, Giuseppe
    Brancato, Luigi
    Puers, Robert
    Costantino, Cosimo
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2019, 55 (02) : 265 - 280
  • [39] Gait, freezing of gait and falls detection using wearable sensors: A systematic review
    Lima, A. L. Silvade
    Evers, L. J. W.
    Hahn, T.
    Bataille, L.
    Hamilton, J. L.
    Little, M. A.
    Bloem, B. R.
    Faber, M. J.
    MOVEMENT DISORDERS, 2017, 32
  • [40] Measuring gait kinematics in patients with severe hip osteoarthritis using wearable sensors
    Ismailidis, Petros
    Nuesch, Corina
    Kaufmann, Mara
    Clauss, Martin
    Pagenstert, Geert
    Eckardt, Anke
    Ilchmann, Thomas
    Mundermann, Annegret
    GAIT & POSTURE, 2020, 81 : 49 - 55