Evaluating the cracking behavior of ECC beam-column connections under cyclic loading by acoustic emission analysis

被引:19
|
作者
Abouhussien, Ahmed A. [1 ]
Hassan, Assem A. A. [2 ]
Ismail, Mohamed K. [2 ,3 ]
AbdelAleem, Basem H. [2 ]
机构
[1] Univ Toronto, Dept Civil & Mineral Engn, Toronto, ON M5S 1A4, Canada
[2] Mem Univ Newfoundland, Dept Civil Engn, Fac Engn & Appl Sci, St John, NF A1B 3X5, Canada
[3] Cairo Univ, Dept Struct Engn, Giza, Egypt
基金
加拿大自然科学与工程研究理事会;
关键词
Acoustic emission monitoring; Engineered cementitious composites; Beam-column connections; Cyclic load tests; b-Value; Intensity analysis; ENGINEERED CEMENTITIOUS COMPOSITES; B-VALUE ANALYSIS; REINFORCED-CONCRETE; PVA FIBER; PULL-OUT; FLY-ASH; DAMAGE; TENSILE; PERFORMANCE; MECHANISMS;
D O I
10.1016/j.conbuildmat.2019.04.213
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results from an experimental program conducted to assess the cracking behavior of reinforced concrete beam-column connections cast with engineered cementitious composites (ECC). Reversed cyclic loading tests in conjunction with acoustic emission (AE) monitoring were completed on all specimens till failure. Four ECC mixtures containing four different types of fibers along with a control conventional concrete (CC) mixture were tested. The AE data obtained from all tests were filtered and analyzed to identify and evaluate the crack growth in all beam-column connections. First, the changes in the AE parameters such as signal amplitudes, number of hits, and cumulative signal strength were considered. Then, additional b-value and intensity analyses on both signal amplitude and strength were performed to develop three further AE parameters including b-value, historic index (H (t)), and severity (S-r). The impact of fibers type and sensor location on the aforementioned AE parameters was examined. The AE analysis completed in this study led to the identification of the first cracks prior to their visual observation, regardless of fibers type and/or sensor location. The studied AE parameters were highly correlated to the process of crack propagation in all specimens until failure. The results also showed that varying the types of fibers in ECC yielded non-significant effect on the AE signal characteristics (in terms of signal amplitudes) throughout the tests. The intensity analysis parameters (H (t) and S-r) were eventually used to generate a damage classification chart to classify the stages of first crack and maximum load in the tested specimens. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:958 / 968
页数:11
相关论文
共 50 条
  • [11] Cyclic Behavior of Beam-Column Connections in Precast Structures
    Meydanli Atalay, Hilal
    Ozden, Sevket
    FRONTIERS IN BUILT ENVIRONMENT, 2021, 7
  • [12] Cyclic flexural analysis and behavior of beam-column connections with gusset plates
    Stoakes, Christopher D.
    Fahnestock, Larry A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 72 : 227 - 239
  • [13] Seismic Behavior of RC wide beam-column connections under dynamic loading
    Benavent-Climent, A.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2007, 11 (04) : 493 - 511
  • [14] Structural behaviour of CFRP strengthened beam-column connections under monotonic and cyclic loading
    Tafsirojjaman, T.
    Fawzia, Sabrina
    Thambiratnam, David P.
    STRUCTURES, 2021, 33 : 2689 - 2699
  • [15] Performance of exterior precast concrete beam-column dowel connections under cyclic loading
    Vidjeapriya, R.
    Vasanthalakshmi, V.
    Jaya, K. P.
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2014, 12 (1A) : 82 - 94
  • [16] Structural behavior of RC engineered cementitious composite (ECC) exterior beam-column joints under reversed cyclic loading
    Said, Shwan H.
    Razak, Hashim Abdul
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 107 : 226 - 234
  • [17] Structural behaviour of RC-ECC beam-column connections under quasi-static loading
    Gul, Mian Asfahan Ali
    Khan, Sajjad Wali
    Ishaq, Muhammad
    Khan, Fasih Ahmed
    Shahzada, Khan
    Gul, Mian Safwat Ali
    MATERIALS TODAY COMMUNICATIONS, 2023, 35
  • [18] Behavior of beam-column connections under axial column tension
    Higazy, EMM
    Elnashai, AS
    Agbabian, MS
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (05): : 501 - 511
  • [19] Behavior of beam-column joints made of sustainable concrete under cyclic loading
    Corinaldesi, Valeria
    Moriconi, Giacomo
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2006, 18 (05) : 650 - 658
  • [20] Construction joints in substandard beam-column connections subjected to cyclic loading
    Roy, Biswajit
    Laskar, Aminul Islam
    MAGAZINE OF CONCRETE RESEARCH, 2020, 72 (08) : 379 - 391