Evaluating the cracking behavior of ECC beam-column connections under cyclic loading by acoustic emission analysis

被引:19
|
作者
Abouhussien, Ahmed A. [1 ]
Hassan, Assem A. A. [2 ]
Ismail, Mohamed K. [2 ,3 ]
AbdelAleem, Basem H. [2 ]
机构
[1] Univ Toronto, Dept Civil & Mineral Engn, Toronto, ON M5S 1A4, Canada
[2] Mem Univ Newfoundland, Dept Civil Engn, Fac Engn & Appl Sci, St John, NF A1B 3X5, Canada
[3] Cairo Univ, Dept Struct Engn, Giza, Egypt
基金
加拿大自然科学与工程研究理事会;
关键词
Acoustic emission monitoring; Engineered cementitious composites; Beam-column connections; Cyclic load tests; b-Value; Intensity analysis; ENGINEERED CEMENTITIOUS COMPOSITES; B-VALUE ANALYSIS; REINFORCED-CONCRETE; PVA FIBER; PULL-OUT; FLY-ASH; DAMAGE; TENSILE; PERFORMANCE; MECHANISMS;
D O I
10.1016/j.conbuildmat.2019.04.213
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results from an experimental program conducted to assess the cracking behavior of reinforced concrete beam-column connections cast with engineered cementitious composites (ECC). Reversed cyclic loading tests in conjunction with acoustic emission (AE) monitoring were completed on all specimens till failure. Four ECC mixtures containing four different types of fibers along with a control conventional concrete (CC) mixture were tested. The AE data obtained from all tests were filtered and analyzed to identify and evaluate the crack growth in all beam-column connections. First, the changes in the AE parameters such as signal amplitudes, number of hits, and cumulative signal strength were considered. Then, additional b-value and intensity analyses on both signal amplitude and strength were performed to develop three further AE parameters including b-value, historic index (H (t)), and severity (S-r). The impact of fibers type and sensor location on the aforementioned AE parameters was examined. The AE analysis completed in this study led to the identification of the first cracks prior to their visual observation, regardless of fibers type and/or sensor location. The studied AE parameters were highly correlated to the process of crack propagation in all specimens until failure. The results also showed that varying the types of fibers in ECC yielded non-significant effect on the AE signal characteristics (in terms of signal amplitudes) throughout the tests. The intensity analysis parameters (H (t) and S-r) were eventually used to generate a damage classification chart to classify the stages of first crack and maximum load in the tested specimens. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:958 / 968
页数:11
相关论文
共 50 条
  • [1] Acoustic Emission Analysis of Self-Consolidating Rubberized Concrete Beam-Column Connections under Cyclic Loading
    Abouhussien, Ahmed A.
    Hassan, Assem A. A.
    AbdelAleem, Basem H.
    ACI STRUCTURAL JOURNAL, 2019, 116 (06) : 41 - 51
  • [2] Experimental study on seismic behavior of precast beam-column connections under cyclic loading
    Zhang, Qian
    Wang, Shuo
    Meloni, Marco
    Feng, Jian
    Xu, Jian
    Cai, Jianguo
    Structural Concrete, 2021, 22 (03): : 1315 - 1326
  • [3] Experimental study on seismic behavior of precast beam-column connections under cyclic loading
    Zhang, Qian
    Wang, Shuo
    Meloni, Marco
    Feng, Jian
    Xu, Jian
    Cai, Jianguo
    STRUCTURAL CONCRETE, 2021, 22 (03) : 1315 - 1326
  • [4] Cyclic Loading Behavior of Weak Reinforced Concrete Beam-Column Connections
    Jiang, Lixue
    Zheng, Shiju
    Zhang, Weiping
    Gu, Xianglin
    ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 881 - +
  • [5] Beam-column composite connections under cyclic loading: an experimental study
    Kataoka, Marcela Novischi
    Homce de Cresce El Debs, Ana Lucia
    MATERIALS AND STRUCTURES, 2015, 48 (04) : 929 - 946
  • [6] Numerical modeling the effect of an opening on the behavior of exterior beam-column connections under cyclic loading
    Amin, Saleh
    Elwan, S. K.
    Elzeiny, S.
    Hamad, M.
    Deifalla, A.
    JOURNAL OF BUILDING ENGINEERING, 2021, 40
  • [7] Effect of Cyclic Loading Frequency on the Behavior of External RC Beam-Column Connections
    Marthong, Comingstarful
    Dutta, Anjan
    Deb, Sajal K.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2016, 20 (07) : 1126 - 1147
  • [8] A study on the size effect of RC beam-column connections under cyclic loading
    Barbhuiya, Salim
    Choudhury, Abdul Munim
    ENGINEERING STRUCTURES, 2015, 95 : 1 - 7
  • [9] Damage progression in RC beam-column joints under cyclic loading using acoustic emission technique
    Singh, Shamsher
    Sharma, Shruti
    Kwatra, Naveen
    STRUCTURAL CONCRETE, 2021, 22 (06) : 3556 - 3573
  • [10] Behavior of SFRC interior beam-column joints under cyclic loading
    Khalaf, Noor Ayaad
    Qissab, Musab Aied
    STRUCTURAL MONITORING AND MAINTENANCE, 2020, 7 (03): : 167 - 193