Prospective MR Image Alignment Between Breath-Holds: Application to Renal BOLD MRI

被引:2
|
作者
Kalis, Inge M. [1 ]
Pilutti, David [1 ]
Krafft, Axel J. [1 ,2 ,3 ]
Hennig, Juergen [1 ]
Bock, Michael [1 ]
机构
[1] Univ Med Ctr Freiburg, Dept Radiol Med Phys, Breisacher Str 60a, D-79106 Freiburg, Germany
[2] German Canc Consortium, Heidelberg, Germany
[3] German Canc Res Ctr, Heidelberg, Germany
关键词
renal oxygenation measurement; prospective motion correction; image registration; BOLD; R2*; INTRARENAL OXYGENATION; MEDULLARY OXYGENATION; WATER DIURESIS; NAVIGATOR; MOTION; REGISTRATION;
D O I
10.1002/mrm.26247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present an image registration method for renal blood oxygen level-dependent (BOLD) measurements that enables semiautomatic assessment of parenchymal and medullary R2* changes under a functional challenge. Methods: In a series of breath-hold acquisitions, three-dimensional data were acquired initially for prospective image registration of subsequent BOLD measurements. An algorithm for kidney alignment for BOLD renal imaging (KALIBRI) was implemented to detect the positions of the left and right kidney so that the kidneys were acquired in the subsequent BOLD measurement at consistent anatomical locations. Residual in-plane distortions were corrected retrospectively so that semiautomatic dynamic R2* measurements of the renal cortex and medulla become feasible. KALIBRI was tested in six healthy volunteers during a series of BOLD experiments, which included a 600- to 1000-mL water challenge. Results: Prospective image registration and BOLD imaging of each kidney was achieved within a total measurement time of about 17 s, enabling its execution within a single breath-hold. KALIBRI improved the registration by up to 35% as found with mutual information measures. In four volunteers, a medullary R2* decrease of up to 40% was observed after water ingestion. Conclusion: KALIBRI improves the quality of two-dimensional time-resolved renal BOLD MRI by aligning local renal anatomy, which allows for consistent R2* measurements over many breath-holds. (C) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1573 / 1582
页数:10
相关论文
共 41 条
  • [21] Automatic alignment of renal DCE-MRI image series for improvement of quantitative tracer kinetic studies
    Zikic, Darko
    Sourbron, Steven
    Feng, Xinxing
    Michaely, Henrik J.
    Khamene, Ali
    Navab, Nassir
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914
  • [22] Application of BOLD MRI and DTI for the Evaluation of Renal Effect Related to Viscosity of Iodinated Contrast Agent in a Rat Model
    Wang, Yi
    Ren, Ke
    Liu, Yi
    Sun, Wen-ge
    Wang, Jia-huan
    Zhang, Xin
    Wu, Cheng-hua
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (05) : 1320 - 1331
  • [23] A Multi-Modality Image Atlas for Transforming An MR Image Into a Pseudo CT Image for MRI-Based IGRT Application
    Zhang, L.
    Michel, K.
    Yang, J.
    Rubinstein, A.
    Kingsley, C.
    Delacerda, J.
    Balter, P.
    Court, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Comparison of single-breath-hold fast spin-echo sequences with routine non-breath-hold techniques: Application to MRI of renal masses
    Melki, PS
    Argaud, C
    Suminski, M
    Helenon, O
    Belin, X
    Millet, P
    Chretien, Y
    Zannoli, G
    Moreau, JF
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 608 - 614
  • [25] Diffusion-Weighted MRI in the Assessment of Split Renal Function: Comparison of Navigator-Triggered Prospective Acquisition Correction and Breath-Hold Acquisition
    Li, Qinghai
    Wu, Xinying
    Qiu, Lingling
    Zhang, Peipei
    Zhang, Minming
    Yan, Fuhua
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 113 - 119
  • [26] Renal arterial stenosis: Prospective comparison of color Doppler US and breath-hold, three-dimensional, dynamic, gadolinium-enhanced MR angiography
    De Cobelli, F
    Venturini, M
    Vanzulli, A
    Sironi, S
    Salvioni, M
    Angeli, E
    Scifo, P
    Garancini, MP
    Quartagno, R
    Bianchi, G
    Del Maschio, A
    RADIOLOGY, 2000, 214 (02) : 373 - 380
  • [27] Prospective Image Quality and Lesion Assessment in the Setting of MR-Guided Radiation Therapy of Prostate Cancer on an MR-Linac at 1.5 T: A Comparison to a Standard 3 T MRI
    Almansour, Haidara
    Afat, Saif
    Fritz, Victor
    Schick, Fritz
    Nachbar, Marcel
    Thorwarth, Daniela
    Zips, Daniel
    Mueller, Arndt-Christian
    Nikolaou, Konstantin
    Othman, Ahmed E.
    Wegener, Daniel
    CANCERS, 2021, 13 (07)
  • [28] A prospective randomized comparison between two MRI studies of the small bowel in Crohn's disease, the oral contrast method and MR enteroclysis
    Negaard, Anne
    Paulsen, Vemund
    Sandvik, Leiv
    Berstad, Audun Elnaes
    Borthne, Arne
    Try, Kirsti
    Lygren, Idar
    Storaas, Tryggve
    Klow, Nils-Einar
    EUROPEAN RADIOLOGY, 2007, 17 (09) : 2294 - 2301
  • [29] A prospective randomized comparison between two MRI studies of the small bowel in Crohn’s disease, the oral contrast method and MR enteroclysis
    Anne Negaard
    Vemund Paulsen
    Leiv Sandvik
    Audun Elnaes Berstad
    Arne Borthne
    Kirsti Try
    Idar Lygren
    Tryggve Storaas
    Nils-Einar Klow
    European Radiology, 2007, 17 : 2294 - 2301
  • [30] Prospective Evaluation of the Image Quality and Tumor Lesion Assessment for the Radiotherapy of Prostate Cancer on the MR-Linac: A Comparison with a diagnostic 3T MRI
    Almansour, H.
    Afat, S.
    Schick, F.
    Nachbar, M.
    Thorwarth, D.
    Zips, D.
    Fritz, V.
    Mueller, A. -C.
    Nikolaou, K.
    Othman, A.
    Wegener, D.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (SUPPL 1) : S160 - S161