Prospective MR Image Alignment Between Breath-Holds: Application to Renal BOLD MRI

被引:2
|
作者
Kalis, Inge M. [1 ]
Pilutti, David [1 ]
Krafft, Axel J. [1 ,2 ,3 ]
Hennig, Juergen [1 ]
Bock, Michael [1 ]
机构
[1] Univ Med Ctr Freiburg, Dept Radiol Med Phys, Breisacher Str 60a, D-79106 Freiburg, Germany
[2] German Canc Consortium, Heidelberg, Germany
[3] German Canc Res Ctr, Heidelberg, Germany
关键词
renal oxygenation measurement; prospective motion correction; image registration; BOLD; R2*; INTRARENAL OXYGENATION; MEDULLARY OXYGENATION; WATER DIURESIS; NAVIGATOR; MOTION; REGISTRATION;
D O I
10.1002/mrm.26247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present an image registration method for renal blood oxygen level-dependent (BOLD) measurements that enables semiautomatic assessment of parenchymal and medullary R2* changes under a functional challenge. Methods: In a series of breath-hold acquisitions, three-dimensional data were acquired initially for prospective image registration of subsequent BOLD measurements. An algorithm for kidney alignment for BOLD renal imaging (KALIBRI) was implemented to detect the positions of the left and right kidney so that the kidneys were acquired in the subsequent BOLD measurement at consistent anatomical locations. Residual in-plane distortions were corrected retrospectively so that semiautomatic dynamic R2* measurements of the renal cortex and medulla become feasible. KALIBRI was tested in six healthy volunteers during a series of BOLD experiments, which included a 600- to 1000-mL water challenge. Results: Prospective image registration and BOLD imaging of each kidney was achieved within a total measurement time of about 17 s, enabling its execution within a single breath-hold. KALIBRI improved the registration by up to 35% as found with mutual information measures. In four volunteers, a medullary R2* decrease of up to 40% was observed after water ingestion. Conclusion: KALIBRI improves the quality of two-dimensional time-resolved renal BOLD MRI by aligning local renal anatomy, which allows for consistent R2* measurements over many breath-holds. (C) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1573 / 1582
页数:10
相关论文
共 41 条
  • [1] Improved accelerated breath-hold radial cine image reconstruction by acquiring additional free-breathing data between breath-holds
    Seunghoon Nam
    Mehmet Akcakaya
    Yongjun Kwak
    Beth Goddu
    Kraig V Kissinger
    Warren J Manning
    Vahid Tarokh
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [2] AI-augmented reconstruction provides improved image quality and enables shorter breath-holds in contrast-enhanced liver MRI
    Francesca Castagnoli
    Mihaela Rata
    Joshua Shur
    Georgina Hopkinson
    Alison Macdonald
    David Stockton
    Marcel Dominik Nickel
    Stephan Kannengiesser
    Christina Messiou
    Dow-Mu Koh
    Jessica Mary Winfield
    European Radiology Experimental, 9 (1)
  • [3] First MRI based quantification of diaphragm motion during prolonged breath-holds up to 8 minutes
    Van Dijk, I.
    Parkes, M. J.
    Stevens, M. F.
    Balasupramaniam, P.
    Van den Aardweg, J. G.
    Van Tienhoven, G.
    Van Kesteren, Z.
    Bel, A.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S178 - S179
  • [4] 3D CORONARY MR-ANGIOGRAPHY IN MULTIPLE BREATH-HOLDS USING A RESPIRATORY FEEDBACK MONITOR
    WANG, Y
    GRIMM, RC
    ROSSMAN, PJ
    DEBBINS, JP
    RIEDERER, SJ
    EHMAN, RL
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) : 11 - 16
  • [5] Patient-initiated breath-holds in MM: an alternative for reducing respiratory artifacts and improving image quality
    Funk, Eva
    Anderzen-Carlsson, Agneta
    Ingverud, Per
    Leander, Anna
    Thunberg, Per
    CLINICAL IMAGING, 2015, 39 (04) : 619 - 622
  • [6] Comparing the Stability of Deep Inspiration Breath-Holds Between ABC and VisionRT During Breast Irradiation
    Iqbal, Z.
    McBeth, R.
    Joo, M.
    Parsons, D.
    Rahimi, A.
    Kim, N.
    Sawant, A.
    Gu, X.
    Zhao, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E590 - E591
  • [7] Lung and Liver Stereotactic Body Radiation Therapy During Mechanically Assisted Deep Inspiration Breath-Holds: A Prospective Feasibility Trial
    Vander Veken, Loic
    Van Ooteghem, Genevieve
    Ghaye, Benoit
    Razavi, Ariane
    Dechambre, David
    Geets, Xavier
    ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (09)
  • [8] Measuring Vascular Reactivity With Breath-Holds After Stroke: A Method to Aid Interpretation of Group-Level BOLD Signal Changes in Longitudinal fMRI Studies
    Geranmayeh, Fatemeh
    Wise, Richard J. S.
    Leech, Robert
    Murphy, Kevin
    HUMAN BRAIN MAPPING, 2015, 36 (05) : 1755 - 1771
  • [9] Accuracy of abdominal organ motion estimation in radiotherapy using the right hemidiaphragm top as a surrogate during prolonged breath-holds quantified with MRI
    Veldman, Johannes K.
    van Kesteren, Zdenko
    Gunwhy, Ebony R.
    Parkes, Michael J.
    Stevens, Markus F.
    van den Aardweg, Joost G.
    van Tienhoven, Geertjan
    Bel, Arjan
    van Dijk, Irma W. E. M.
    MEDICAL PHYSICS, 2023, 50 (06) : 3299 - 3310
  • [10] Repeated deep-inspiration breath-hold CT scans at planning underestimate the actual motion between breath-holds at treatment for lung cancer and lymphoma patients
    Hoffmann, Lone
    Ehmsen, ML.
    Hansen, J.
    Hansen, R.
    Knap, MM.
    Mortensen, HR.
    Poulsen, PR.
    Ravkilde, T.
    Rose, HK.
    Schmidt, HH.
    Worm, ES.
    Moller, DS.
    RADIOTHERAPY AND ONCOLOGY, 2023, 188