Off-design and annual performance analysis of supercritical carbon dioxide cycle with thermal storage for CSP application

被引:37
|
作者
Thanganadar, Dhinesh [1 ]
Fornarelli, Francesco [2 ,3 ]
Camporeale, Sergio [2 ]
Asfand, Faisal [1 ,4 ]
Patchigolla, Kumar [1 ]
机构
[1] Cranfield Univ, Sch Water Energy & Environm SWEE, Cranfield MK43 0AL, Beds, England
[2] Politecn Bari, Dipartimento Meccan Matemat & Management DMMM, Bari, Italy
[3] Natl Inst High Math INDAM, Natl Grp Math Phys GNFM, Rome, Italy
[4] Univ Huddersfield, Sch Comp & Engn, Huddersfield HD1 3DH, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Supercritical CO2 cycle; CSP; Annual performance; Multi-objective optimisation; Thermal energy storage; Off-design; BRAYTON CYCLE; GENETIC ALGORITHM; POWER CONVERSION; HEAT-EXCHANGERS; CO2;
D O I
10.1016/j.apenergy.2020.116200
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Supercritical Carbon Dioxide (sCO(2)) cycles can achieve higher efficiency compared to steam-Rankine or AirBrayton cycles, therefore they are promising for concentrated solar power applications. Although sCO(2) cycles show higher design efficiency, the off-design efficiency is highly sensitive to the ambient conditions, impacting the power block net-power and heat input. In the present work a recompression sCO(2) cycle is connected to a central-tower solar field with two-tank thermal storage delivering molten chloride salt at 670 degrees C. The temperature of the molten-salt exiting from the power block and returning to the cold storage tank increases by 46 degrees C with respect to the design value when the compressor inlet temperature is raised by 13 degrees C relative to the design condition of 42 degrees C, which implies that the capacity of the thermal storage reduces by 25%. The main focus of this work is to investigate the off-design performance of a sCO(2) recompression cycle under variable ambient temperature, molten-salt inlet temperature and molten-salt flow rate. Multi-objective optimisation is carried-out in off-design conditions using an in-house code to explore the optimal operational strategies and the Pareto fronts were compared. Since the power cycle can either be operated in maximum power mode or maximum efficiency mode, this study compares these two operational strategies based on their annual performance. Results indicate that the capacity factor of the concentrated solar power can be increased by 10.8% when operating in maximum power mode whilst the number of start-ups is reduced by about 50% when operating in maximum efficiency mode.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] One-dimensional optimisation design and off-design operation strategy of centrifugal compressor for supercritical carbon dioxide Brayton cycle
    Du, Yadong
    Yang, Ce
    Wang, Haimei
    Hu, Chenxing
    APPLIED THERMAL ENGINEERING, 2021, 196
  • [22] Off-design Performance of Compressed Air Energy Storage System With Thermal Storage
    Guo H.
    Xu Y.
    Zhang X.
    Guo C.
    Chen H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (05): : 1366 - 1376
  • [23] Research on the Performance of 1000MW Supercritical Carbon Dioxide Power Cycle Coal-fired Unit Under Off-design Conditions
    Chen J.
    Chen L.
    Zhou J.
    Zhu M.
    Liao H.
    Liu H.
    Xu K.
    Xiang J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (17): : 6681 - 6687
  • [24] Design and off-design performance analysis of a liquid carbon dioxide energy storage system integrated with low-grade heat source
    Xu, Wenpan
    Zhao, Pan
    Liu, Aijie
    Wu, Wenze
    Wang, Jiangfeng
    APPLIED THERMAL ENGINEERING, 2023, 228
  • [25] Off-design modeling and performance analysis of supercritical compressed air energy storage systems with packed bed cold storage
    Guo, Huan
    Xu, Yujie
    Zhu, Yilin
    Chen, Haisheng
    JOURNAL OF ENERGY STORAGE, 2022, 52
  • [26] Investigation of off-design performance of supercritical carbon dioxide recompression cycle using a deep learning-based turbine with variable inlet guide vanes
    Du, Yadong
    Yang, Ce
    Zhao, Ben
    Wang, Haimei
    Zhang, Hanzhi
    He, Xinyu
    Hu, Chenxing
    Li, Yanzhao
    ENERGY CONVERSION AND MANAGEMENT, 2023, 286
  • [27] Design optimization and off-design performance analysis of one-dimensional supercritical CO2 Brayton cycle
    Li, Hao
    Zhang, Ruhai
    Li, Zhen
    Lee, Sangkyoung
    Ju, Yaping
    Zhang, Chuhua
    Lu, Yuanshen
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [28] Off-design performance analysis of supercritical CO2 mixture Brayton cycle with floating critical points
    Luo, Yiyang
    Su, Zhanhang
    Li, Ziyang
    Zheng, Nan
    Wei, Jinjia
    SOLAR ENERGY, 2024, 276
  • [29] Performance Evaluation of Supercritical Carbon Dioxide Recompression Cycle for High Temperature Electric Thermal Energy Storage
    Oh, Seunghwan
    Oh, Bong Seong
    Lee, Jeong Ik
    ENERGY CONVERSION AND MANAGEMENT, 2022, 255
  • [30] Performance Analysis and Optimization Design Method of Supercritical Carbon Dioxide Recompression Brayton Cycle
    Yao L.-C.
    Zou Z.-P.
    Fu C.
    Liu H.-X.
    Tuijin Jishu/Journal of Propulsion Technology, 2022, 43 (03):