Optimizing analysis of stable isotope breath tests to estimate gastric emptying of solids

被引:39
|
作者
Odunsi, S. T. [1 ]
Camilleri, M. [1 ]
Szarka, L. A. [1 ]
Zinsmeister, A. R. [2 ]
机构
[1] Mayo Clin, CENTER, Rochester, MN 55905 USA
[2] Mayo Clin, Div Biostat, Dept Hlth Sci, Rochester, MN 55905 USA
来源
NEUROGASTROENTEROLOGY AND MOTILITY | 2009年 / 21卷 / 07期
基金
美国国家卫生研究院;
关键词
scintigraphy; spirulina; SCINTIGRAPHY; MEAL;
D O I
10.1111/j.1365-2982.2009.01283.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Breath tests (BT) using C-13-substrates have been proposed for the measurement of gastric emptying (GE). The mathematical analysis of the breath (CO2)-C-13 excretion that most accurately predicts GE t(1/2) from simultaneous scintigraphy is unresolved. To compare five mathematical methods to estimate GE t(1/2) by BT with t(1/2) from simultaneous scintigraphy. Data acquired from a dual-labelled solid-liquid meal containing Tc-99m sulphur colloid and C-13-Spirulina platensis from 57 healthy volunteers were used to compare four mathematical methods reported in the literature [Ghoos method; generalized linear regression (Viramontes); linear regression (Szarka); Wagner-Nelson method] and the total cumulative breath (CO2)-C-13 excretion with >= 12 breath samples collected over at least 4 h. The concordance correlation coefficient (CCC) for the t(1/2) results obtained with each method using BT data was compared with the results obtained with scintigraphy. The linear regression and generalized linear regression methods used five samples at 45, 90, 120, 150 and 180 min. All methods, except for the Wagner-Nelson method, resulted in mean GE t(1/2) that approximated t(1/2) obtained with scintigraphy. The highest CCC was observed with the linear regression method. Simple cumulative excretion of breath (CO2)-C-13 provides a better CCC than the Ghoos method. The linear regression and generalized linear regression methods (which also require relatively few breath samples) provide the most accurate analyses of breath (CO2)-C-13 excretion in stable isotope GEBT.
引用
收藏
页码:706 / E38
页数:7
相关论文
共 50 条
  • [21] Comparison of calculations to estimate gastric emptying half-time of solids in humans
    Zinsmeister, A. R.
    Bharucha, A. E.
    Camilleri, M.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2012, 24 (12): : 1142 - 1145
  • [22] Correlation of ileal emptying and gastric emptying calculated from a simultaneous application of two breath tests.
    Geypens, B
    Maes, B
    Ghoos, Y
    Luypaerts, A
    Rutgeerts, P
    GASTROENTEROLOGY, 1998, 114 (04) : A755 - A755
  • [23] 13C-octanoic acid breath test for gastric emptying rate of solids
    Maes, BD
    Geypens, BJ
    Ghoos, YF
    Hiele, MI
    Rutgeerts, RJ
    GASTROENTEROLOGY, 1998, 114 (04) : 856 - 857
  • [24] Dynamic carbon 13 breath tests for the study of liver function and gastric emptying
    Bonfrate, Leonilde
    Grattagliano, Ignazio
    Palasciano, Giuseppe
    Portincasa, Piero
    GASTROENTEROLOGY REPORT, 2015, 3 (01): : 12 - 21
  • [25] Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids
    Choi, MG
    Camilleri, M
    Burton, DD
    Zinsmeister, AR
    Forstrom, LA
    Nair, KS
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1998, 93 (01): : 92 - 98
  • [26] Reproducibility of the 13 C octanoic acid breath test for gastric emptying of solids in children.
    不详
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2005, 41 : S70 - S70
  • [27] Stable isotope analysis of breath using the optogalvanic effect
    Murnick, DE
    Colgan, MJ
    Lie, HP
    Stoneback, D
    OPTICAL DIAGNOSTICS OF LIVING CELLS AND BIOFLUIDS, PROCEEDINGS OF, 1996, 2678 : 454 - 463
  • [28] 13C-gastric emptying breath tests: Clinical use in adults and children
    Keller, Jutta
    Hammer, Heinz F.
    Hauser, Bruno
    NEUROGASTROENTEROLOGY AND MOTILITY, 2021, 33 (06):
  • [29] A COMPARISON OF METHODS OF ANALYSIS OF GASTRIC-EMPTYING TESTS
    ABELL, TL
    SCHWARTZBAUM, J
    WILSON, R
    MASSIE, D
    CLINICAL RESEARCH, 1989, 37 (01): : A32 - A32
  • [30] Further validation of the [13C]octanoic acid breath test for gastric emptying of solids.
    Drewe, J
    Hildebrand, P
    Descloux, L
    Beglinger, C
    GASTROENTEROLOGY, 1998, 114 (04) : A745 - A745