Pilot scale membrane separation of electroplating waste water by reverse osmosis

被引:13
|
作者
Chai, XJ [1 ]
Chen, GH [1 ]
Yue, PL [1 ]
Mi, YL [1 ]
机构
[1] HONG KONG UNIV SCI & TECHNOL,DEPT CHEM ENGN,KOWLOON,HONG KONG
关键词
reverse osmosis; pilot scale; electroplating copper waste water;
D O I
10.1016/S0376-7388(96)00217-7
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Electroplating waste water containing copper was treated by means of reverse osmosis (RO) membrane separation on a pilot scale. The copper concentration in the untreated waste water was 340 ppm. After the treatment, the concentration in the treated water was below 4 ppm which is the Hong Kong government discharge limit. It is shown that, by increasing transmembrane pressure drop, metal concentrations in the treated water can be further reduced. This study suggests that larger scale operations on treating electroplating waste water by RO membrane separation is possible and effective. Effects of operating variables including transmembrane pressure drop and temperature on membrane separation performance were studied and explained based on the solution-diffusion model. The present study is part of the recent investigation of industrial waste water management sponsored by the Hong Kong Government. The purpose of this project is to provide guidelines to the local industries for waste minimization which is closely monitored by the Hong Kong legislature.
引用
收藏
页码:235 / 242
页数:8
相关论文
共 50 条
  • [31] Pilot scale fabrication of low fouling seawater desalination thin film composite reverse osmosis membrane
    Bera, Parthapratim
    Dhivagaran, D.
    Saha, Nirmal Kumar
    Jewrajka, Suresh K.
    DESALINATION, 2024, 586
  • [32] Pilot scale study of chlorination-induced transport property changes of a seawater reverse osmosis membrane
    Ettori, Axel
    Gaudichet-Maurin, Emmanuelle
    Aimar, Pierre
    Causserand, Christel
    DESALINATION, 2013, 311 : 24 - 30
  • [33] Pilot-Scale Test Results of Electrodialysis Bipolar Membrane for Reverse-Osmosis Concentrate Recovery
    Gazigil, Leyla
    Er, Eren
    Kestioglu, O. Erdem
    Yonar, Taner
    MEMBRANES, 2022, 12 (01)
  • [34] Performance and fouling characteristics in a pilot-scale reverse osmosis membrane system for microelectronic wastewater treatment
    Li, Xianfeng
    Lin, Ling
    Zhang, Xiaoxin
    Dai, Ruobin
    Wu, Zhichao
    Wang, Zhiwei
    SEPARATION AND PURIFICATION TECHNOLOGY, 2024, 337
  • [35] Pilot-scale membrane bioreactor and reverse osmosis studies for direct reuse of secondary textile effluents
    Rozzi, A
    Malpei, F
    Bianchi, R
    Mattioli, D
    WATER SCIENCE AND TECHNOLOGY, 2000, 41 (10-11) : 189 - 195
  • [36] Removal of Tetracycline and Oxytetracycline in Water by a Reverse Osmosis Membrane
    Li, Wei-ying
    Wang, Qing
    Xiao, Qian-fen
    Dong, Bing-zhi
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 3327 - +
  • [37] Dynamics of water sorbed in reverse osmosis polyamide membrane
    Sharma, V. K.
    Singh, P. S.
    Gautam, S.
    Maheshwari, P.
    Dutta, D.
    Mukhopadhyay, R.
    JOURNAL OF MEMBRANE SCIENCE, 2009, 326 (02) : 667 - 671
  • [38] Separation of some light monocarboxylic acids from water in binary solutions in a reverse osmosis pilot plant
    Ragaini, V
    Pirola, C
    Elli, A
    DESALINATION, 2005, 171 (01) : 21 - 32
  • [39] Reverse osmosis membrane
    Inoue, T
    SEN-I GAKKAISHI, 2004, 60 (06) : P295 - P297
  • [40] Full-scale experience with the membrane bioreactor-reverse osmosis water reclamation process
    Daigger, Glen T.
    Hodgkinson, Andrew
    Skeels, Peter
    Smith, Jenine
    Lozier, James
    Fries, Kim
    JOURNAL OF WATER REUSE AND DESALINATION, 2016, 6 (02): : 235 - 248