Bond strength, biaxial flexural strength and flexural modulus of dentin bonding systems exposed to water

被引:5
|
作者
Carvalho, A. O. [1 ]
Carrilho, M. R. O. [2 ]
Rueggeberg, F. A. [3 ]
Ambrosaho, G. M. B. [4 ]
Giannini, M. [1 ]
机构
[1] Univ Estadual Campinas, Dept Restorat Dent, Piracicaba Dent Sch, BR-13414903 Piracicaba, SP, Brazil
[2] Univ Bandeirante Sao Paulo, Biomaterials Res Grp, GEO UNIBAN, Sao Paulo, Brazil
[3] Georgia Regents Univ, Sch Dentishy, Dept Oral Rehabil, Augusta, GA USA
[4] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Social Dent, Piracicaba, SP, Brazil
关键词
Bonding agents; Bond strength; Biaxial flexural strength; Modulus; SINGLE-STEP ADHESIVES; INTERFACIAL ULTRAMORPHOLOGY; AGENTS; NANOLEAKAGE; SORPTION; ENAMEL;
D O I
10.1016/j.ijadhadh.2013.12.017
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Purpose: This study evaluated the effects of storage time on dentin bond strength, biaxial flexural strength, and flexural modulus of four adhesive systems. Materials and Methods: The following adhesive systems were tested: Easy Bond, Scotchbond SE, Single Bond Plus, and Scotchbond Multi-Purpose. Sixty human third molars were used for the microtensile bond strength test (n=15). The adhesives were applied to flat occlusal dentin surfaces according to the manufacturers' instructions and a Filtek Supreme resin composite block (6 mm high) was incrementally built up. After 24 h, the teeth were prepared for the bond strength test. The specimens were stored for one week, six months, and one year in distilled water. At the end of each storage period, the specimens were tested under tension (0.5 mm/min) until failure occurred. For the biaxial flexural test, resin discs of each adhesive (0.6 mm thick and 6.0 mm in diameter) were prepared in silicon molds (n=10). The discs were stored for the same storage periods in distilled water prior to testing in a universal testing machine (1.27 mm/min). Data were analyzed using two-way analysis of variance and Tukey's test (alpha=0.05). Results: Bond strength values decreased significantly after six months and one year of water storage only for Scotchbond SE (from 48.1 +/- 11.0 to 24.5 +/- 15.3 MPa after one year). The storage time did not affect the flexural strength or modulus for any adhesive tested. Conclusion: Water storage for six months or one year can reduce the dentin bond strength of adhesives; however, the results are product-dependent. No changes in flexural strength or modulus of the adhesives tested were observed after storage of any duration. (C) 2014 Published by Elsevier Ltd.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [41] Effect of disinfectants on bond strength of dentin bonding systems.
    Say, EC
    Korav, F
    Tarim, B
    Soyman, M
    Gulmez, T
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B277 - B277
  • [42] Microtensile bond strength to dentin of ten current bonding systems
    Moll, K
    Park, H
    Haller, B
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1206 - 1206
  • [43] SHEAR BOND STRENGTH OF 3 MODERN DENTIN BONDING SYSTEMS
    VANDERVYVER, PJ
    DEWET, FA
    DEARLOVE, WR
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 1010 - 1010
  • [44] BOND STRENGTH OF A LUTING COMPOSITE TO DENTIN WITH DIFFERENT BONDING SYSTEMS
    OSULLIVAN, BP
    JOHNSON, PF
    BLOSSER, RL
    RUPP, NW
    LI, SH
    JOURNAL OF PROSTHETIC DENTISTRY, 1987, 58 (02): : 171 - 175
  • [45] Influence of different factors on bond strength of dentin bonding systems
    Friedl, KH
    Hiller, KA
    Schmalz, G
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 508 - 508
  • [46] Bond Strength of Different Dentin Bonding Systems to Fluorotic Enamel
    Ertugrul, Fahinur
    Turkun, Murat
    Turkun, L. Sebnem
    Toman, Muhittin
    Cal, Ebru
    JOURNAL OF ADHESIVE DENTISTRY, 2009, 11 (04): : 299 - 303
  • [47] Effects of various concentrations of hydrogen peroxide bleaching on the flexural strength and modulus of elasticity of dentin.
    Lim, M.
    Khanna, S.
    Tam, L. E.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B132 - B132
  • [48] Shear bond strength to moist and dry dentin of four dentin bonding systems
    Gallo, JR
    Henderson, M
    Burgess, JO
    AMERICAN JOURNAL OF DENTISTRY, 2000, 13 (05): : 267 - 270
  • [49] Bond strength of three different dentin bonding systems to abraded dentin.
    Karakaya, S.
    Uenlue, N.
    Say, E. C.
    Oezer, F.
    Soyman, N.
    Tagami, J.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B331 - B331
  • [50] Flexural strength and modulus of aromatic and aliphatic urethane dimethacrylates
    Kerby, RE
    Knobloch, L
    Lilley, H
    Schricker, S
    Culbertson, B
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A36 - A36