RF Transmit/Receive Quadrature Fed Body Birdcage Coil for a 1.5T MR System

被引:0
|
作者
Yadav, Niraj S. [1 ]
Kochar, Inderkumar [1 ]
Bhuiya, Tapas K. [2 ]
Harsh, Rajesh [2 ]
机构
[1] St Francis Inst Technol, Dept EXTC, Mumbai, Maharashtra, India
[2] SAMEER, Technol Innovat Div, IIT Campus, Powai, India
来源
2018 2ND INTERNATIONAL CONFERENCE ON ELECTRONICS, MATERIALS ENGINEERING & NANO-TECHNOLOGY (IEMENTECH) | 2018年
关键词
Birdcage Coil; Magnetic Resonance Imaging (MRI); Nuclear Magnetic Resonance (NMR); RF Coil; Volume Coil; Quadrature feeding; FIELD MRI; DESIGN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic Resonance Imaging (MRI) is an imaging technique which is used to view the inner part of the human body in a non-invasive manner. This imaging technique is based on the principle of Nuclear Magnetic Resonance (NMR). The Radio-frequency coil in MRI can be of various types. Birdcage Coil is a type of volume coil which is selected for the implementation of the RF coil due to better field homogeneity and high signal to noise ratio which in turn guarantees a large field of view. This paper describes the implementation of a strip based birdcage coil for a Human Body operating in high-pass, low-pass and band-pass modes. Since its introduction, determining the resonant modes has been a difficult task. This paper attempts to determine the resonant modes for high pass and band pass structures for a 1.5T MR System. The resonant frequency for a 1.5T MR system is 63.87 MHz which is obtained by the Larmor equation and is known as the Larmor frequency. The dimensions of the coil are kept constant for all the designs. The theoretical ideas were further validated in a computer simulation for all the three designs.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 50 条
  • [41] MR angiographic evaluation of platinum coil packs at 1.5T and 3T:: An in vitro assessment of artifact production:: Technical note
    Walker, MT
    Tsai, J
    Parish, T
    Tzung, B
    Shaibani, A
    Krupinski, E
    Russell, EJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (04) : 848 - 853
  • [42] MRI-Guided Adaptive Head and Neck Radiotherapy On a 1.5T MR Linac System
    Aliotta, E.
    Hesse, J.
    Subashi, E.
    Scripes, P.
    Aristophanous, M.
    Mechalakos, J.
    Cervino, L.
    Tyagi, N.
    Zakeri, K.
    Lee, N.
    MEDICAL PHYSICS, 2022, 49 (06) : E761 - E761
  • [43] Evaluation of feasibility of 1.5 Tesla prostate MRI using body coil RF transmit in a patient with an implanted vagus nerve stimulator
    Favazza, Christopher P.
    Edmonson, Heidi A.
    Ma, Chi
    Shu, Yunhong
    Felmlee, Joel P.
    Watson, Robert E.
    Gorny, Krzysztof R.
    MEDICAL PHYSICS, 2017, 44 (11) : 5749 - 5754
  • [44] Excessive Temperature Increases in Pacemaker Leads at 3-T MR Imaging with a Transmit-Receive Head Coil Response
    Naehle, Claas P.
    Luechinger, Roger
    Litt, Harold
    Sommer, Torsten
    RADIOLOGY, 2009, 251 (03) : 949 - U431
  • [45] Evaluation of RF interactions between a 3T birdcage transmit coil and transcranial magnetic stimulation coils using a realistically shaped head phantom
    Navarro de Lara, Lucia I.
    Golestanirad, Laleh
    Makarov, Sergey N.
    Stockmann, Jason P.
    Wald, Lawrence L.
    Nummenmaa, Aapo
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 1061 - 1075
  • [46] 7T ultra-high field body MR imaging with an 8-channel transmit/32-channel receive radiofrequency coil array
    Rietsch, Stefan H. G.
    Orzada, Stephan
    Maderwald, Stefan
    Brunheim, Sascha
    Philips, Bart W. J.
    Scheenen, Tom W. J.
    Ladd, Mark E.
    Quick, Harald H.
    MEDICAL PHYSICS, 2018, 45 (07) : 2978 - 2990
  • [47] A birdcage transmit, 24-channel conformal receive array coil for sensitive 31P magnetic resonance spectroscopic imaging of the human brain at 7 T
    Hovagimian, Johnny Der
    Yazdanbakhsh, Pedram
    Halilibrahimoglu, Hande
    Couch, Marcus J.
    Hoge, Richard
    Rudko, David A.
    NMR IN BIOMEDICINE, 2024, 37 (10)
  • [48] Evaluations of the MRI RF-Induced Heating for Helical Stents Under a 1.5T MRI System
    Ji, Xiaohe
    Zheng, Jianfeng
    Yang, Rui
    Kainz, Wolfgang
    Chen, Ji
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2019, 61 (01) : 57 - 64
  • [49] Inter-observer agreement of ACR MRI phantom Test on a 1.5T MR-simulator with Flexible Coil setting
    Yuan, J.
    Wong, O. L.
    Yu, S. K.
    Cheung, K. Y.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S945 - S945
  • [50] The Dosimetric Feasibility of the 1.5T MR-Linac System for Esophageal Cancer: The Impact of the Magnetic Field
    Li, Z.
    Yin, Y.
    Zhu, J.
    Li, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S187 - S187