Parameter Identification with the Random Perturbation Particle Swarm Optimization Method and Sensitivity Analysis of an Advanced Pressurized Water Reactor Nuclear Power Plant Model for Power Systems

被引:5
|
作者
Wang, Li [1 ]
Zhao, Jie [1 ]
Liu, Dichen [1 ]
Lin, Yi [2 ]
Zhao, Yu [1 ]
Lin, Zhangsui [2 ]
Zhao, Ting [1 ]
Lei, Yong [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] State Grid Fujian Elect Power Co Ltd, Econ & Technol Inst, Fuzhou 350012, Peoples R China
基金
中国国家自然科学基金;
关键词
primary loop system model; pressurized water reactor (PWR) units; parameter identification; sensitivity analysis; TRANSIENTS;
D O I
10.3390/en10020173
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The ability to obtain appropriate parameters for an advanced pressurized water reactor (PWR) unit model is of great significance for power system analysis. The attributes of that ability include the following: nonlinear relationships, long transition time, intercoupled parameters and difficult obtainment from practical test, posed complexity and difficult parameter identification. In this paper, a model and a parameter identification method for the PWR primary loop system were investigated. A parameter identification process was proposed, using a particle swarm optimization (PSO) algorithm that is based on random perturbation (RP-PSO). The identification process included model variable initialization based on the differential equations of each sub-module and program setting method, parameter obtainment through sub-module identification in the Matlab/Simulink Software (Math Works Inc., Natick, MA, USA) as well as adaptation analysis for an integrated model. A lot of parameter identification work was carried out, the results of which verified the effectiveness of the method. It was found that the change of some parameters, like the fuel temperature and coolant temperature feedback coefficients, changed the model gain, of which the trajectory sensitivities were not zero. Thus, obtaining their appropriate values had significant effects on the simulation results. The trajectory sensitivities of some parameters in the core neutron dynamic module were interrelated, causing the parameters to be difficult to identify. The model parameter sensitivity could be different, which would be influenced by the model input conditions, reflecting the parameter identifiability difficulty degree for various input conditions.
引用
收藏
页数:22
相关论文
共 29 条
  • [21] State-Space Model Predictive Control Method for Core Power Control in Pressurized Water Reactor Nuclear Power Stations
    Wang, Guoxu
    Wu, Jie
    Zeng, Bifan
    Xu, Zhibin
    Wu, Wanqiang
    Ma, Xiaoqian
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (01) : 134 - 140
  • [22] Research on Evaluation Method of Actinide Nuclide Activities in Primary Coolant System of Pressurized Water Reactor Nuclear Power Plant
    Xiong J.
    Lyu W.
    Guo R.
    Gao Y.
    Jiang Z.
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (02): : 47 - 52
  • [23] Analysis Model and Parameter Optimization of a Silica Removal System for Boric Acid in Nuclear Power Plant
    Xu L.
    Liu B.
    Jiang X.
    Tu Z.
    Hedongli Gongcheng/Nuclear Power Engineering, 2021, 42 (04): : 228 - 232
  • [24] User-defined Modeling of Pressurized Water Reactor Nuclear Power Plant Based on PSASP and Analysis of its Characteristics
    Zhao, Jie
    Wu, Ping
    Liu, Dichen
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 440 - 445
  • [25] Control of the pressurized water nuclear reactors power using optimized proportional-integral-derivative controller with particle swarm optimization algorithm
    Mousakazemi, Seyed Mohammad Hossein
    Ayoobian, Navid
    Ansarifar, Gholam Reza
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2018, 50 (06) : 877 - 885
  • [26] SUBOPTIMAL CONTROL OF PRESSURIZED WATER-REACTOR POWER-PLANT USING APPROXIMATE MODEL-FOLLOWING METHOD
    TSUJI, M
    OGAWA, Y
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1987, 24 (12) : 1022 - 1034
  • [27] Control rod drop analysis by finite element method using fluid-structure interaction for a pressurized water reactor power plant
    Yoon, K. H.
    Kim, J. Y.
    Lee, K. H.
    Lee, Y. H.
    Kim, H. K.
    NUCLEAR ENGINEERING AND DESIGN, 2009, 239 (10) : 1857 - 1861
  • [28] Circulation Water Systems with Natural Draft Cooling Tower for ENEL 660 MW Standard Power Plant. Sensitivity Analysis and Design Parameters Optimization.
    Senis, R.
    Energia Elettrica, 1984, 61 (01): : 28 - 36
  • [29] Performance analysis and structural optimization of NaK78-He plate-fin heat exchanger for space nuclear reactor power systems based on a Q3D numerical method
    Yao, Liang
    Liu, Rui-Tao
    Su, Dan-Dan
    Wang, Su-Ming
    Wang, Lu
    Zhang, Hong-Na
    Li, Xiao-Bin
    Li, Feng-Chen
    NUCLEAR ENGINEERING AND DESIGN, 2025, 434