Enhanced efficiency in helical tomotherapy quality assurance using a custom-designed water-equivalent phantom

被引:9
|
作者
Goddu, S. Murty [1 ]
Mutic, Sasa [1 ]
Pechenaya, Olga L. [1 ]
Chaudhari, Summer R. [1 ]
Garcia-Ramirez, Jose [1 ]
Rangaraj, Dharanipathy [1 ]
Klein, Eric E. [1 ]
Yang, Deshan [1 ]
Grigsby, James [1 ]
Low, Daniel A. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 19期
关键词
RADIOTHERAPY; OUTPUT;
D O I
10.1088/0031-9155/54/19/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tomotherapy is an image-guided, intensity-modulated radiation therapy system that delivers highly conformal dose distributions in a helical fashion. This system is also capable of acquiring megavoltage computed-tomography images and registering them to the planning kVCT images for accurate target localization. Quality assurance (QA) of this device is time intensive, but can be expedited by improved QA tools and procedures. A custom- designed phantom was fabricated to improve the efficiency of daily QA of our Tomotherapy machine. The phantom incorporates ionization chamber measurement points, plugs of different densities and slide-out film cartridges. The QA procedure was designed to verify in less than 30 min the vital components of the tomotherapy system: static beam quality and output, image quality, correctness of image registration and energy of the helical dose delivery. Machine output, percent depth dose and off-axis factors are simultaneously evaluated using a static 5 x 40 cm(2) open field. A single phantom scan is used to evaluate image quality and registration accuracy. The phantom can also be used for patient plan-specific QA. The QA results over a period of 6 months are reported in this paper. The QA process was found to be simple, efficient and capable of simultaneously verifying several important parameters.
引用
收藏
页码:5663 / 5674
页数:12
相关论文
共 33 条
  • [21] A SCANDINAVIAN MULTICENTER QUALITY ASSURANCE PROJECT REGARDING NUCLEAR-MEDICINE BONE IMAGING USING A SPECIALLY DESIGNED ANTHROPOMORPHIC THORACIC PHANTOM
    SKRETTING, A
    LARSSON, SA
    KARKKINEN, A
    ENNOW, K
    SCHNELL, PO
    JOHANSSON, L
    WANG, Y
    HYODYNMAA, S
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (09) : 1837 - 1837
  • [22] Optimization of a Bayesian penalized likelihood algorithm (Q.Clear) for 18F-NaF bone PET/CT images acquired over shorter durations using a custom-designed phantom
    Yoshii, Tokiya
    Miwa, Kenta
    Yamaguchi, Masashi
    Shimada, Kai
    Wagatsuma, Kei
    Yamao, Tensho
    Kamitaka, Yuto
    Hiratsuka, Seiya
    Kobayashi, Rinya
    Ichikawa, Hajime
    Miyaji, Noriaki
    Miyazaki, Tsuyoshi
    Ishii, Kenji
    EJNMMI PHYSICS, 2020, 7 (01)
  • [23] A Fast and Optimized Patient-Specific Quality Assurance Method for Helical Tomotherapy Total Body Irradiation Using a 2-D Array Detector
    Fang, J.
    Zhang, X.
    Yue, Q.
    Narayanasamy, G.
    Penagaricano, J.
    Peacock, L.
    Maraboyina, S.
    Xia, F.
    Morrill, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2897 - 2897
  • [24] Optimization of a Bayesian penalized likelihood algorithm (Q.Clear) for 18F-NaF bone PET/CT images acquired over shorter durations using a custom-designed phantom
    Tokiya Yoshii
    Kenta Miwa
    Masashi Yamaguchi
    Kai Shimada
    Kei Wagatsuma
    Tensho Yamao
    Yuto Kamitaka
    Seiya Hiratsuka
    Rinya Kobayashi
    Hajime Ichikawa
    Noriaki Miyaji
    Tsuyoshi Miyazaki
    Kenji Ishii
    EJNMMI Physics, 7
  • [25] Comparison of 256x0.5mm and 64x0.5mm multidetector computed tomography image quality and accuracy in a custom-designed, motion-simulating phantom of coronary artery stenosis
    Kitagawa, Kakuya
    Arbab-Zadeh, Armin
    Hannon, Katherine M.
    George, Richard T.
    Lima, Joao A.
    Lardo, Albert C.
    CIRCULATION, 2007, 116 (16) : 408 - 409
  • [26] Validation of Intrabeam® Bare Probe 50 KVp X-Ray Source Delivered Dose and Vendor Calculated Dose, Using Reference Dosimetry in a Water-Equivalent Phantom
    Dorgu, A.
    Pavord, D.
    Sherouse, G.
    Gong, J.
    Kriminski, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [27] Controllable Fluid Flow Using Polymer Compartments within a Dynamic Contrast Enhanced (DCE) Imaging Phantom Design for Quality Assurance
    Thomas, A.
    Hollister, S.
    Balter, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [28] Verification of an irregular field algorithm of a treatment planning system using a locally designed pelvic phantom: A simple design low cost phantom suitable for quality assurance and control test in radiotherapy
    Olawale, Oladejo
    Akpochafor, Micheal
    Akintayo, Daniel
    Adeneye, Samuel
    Aweda, Moses
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [29] LINAC QUALITY ASSURANCE USING A 2D DIODE ARRAY DEVICE: IS IT REALLY NECESSARY THE 3D WATER PHANTOM YET?
    Rodriguez Garcia, A.
    Sanchez-Reyes Fernandez, A.
    Loscos, S.
    Vila, A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S519 - S519
  • [30] Surface and build-up dose comparison between Elekta 6 MV flattening filter and flattening-filter-free beams using an advanced Markus ionization chamber and a solid water-equivalent phantom
    Imae, Toshikazu
    Takenaka, Shigeharu
    Watanabe, Yuichi
    Aoki, Atsushi
    Matsuda, Kanako
    Sasaki, Katsutake
    Saegusa, Shigeki
    Nawa, Kanabu
    Nakagawa, Keiichi
    Abe, Osamu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 334 - 339