Enhanced efficiency in helical tomotherapy quality assurance using a custom-designed water-equivalent phantom

被引:9
|
作者
Goddu, S. Murty [1 ]
Mutic, Sasa [1 ]
Pechenaya, Olga L. [1 ]
Chaudhari, Summer R. [1 ]
Garcia-Ramirez, Jose [1 ]
Rangaraj, Dharanipathy [1 ]
Klein, Eric E. [1 ]
Yang, Deshan [1 ]
Grigsby, James [1 ]
Low, Daniel A. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 19期
关键词
RADIOTHERAPY; OUTPUT;
D O I
10.1088/0031-9155/54/19/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tomotherapy is an image-guided, intensity-modulated radiation therapy system that delivers highly conformal dose distributions in a helical fashion. This system is also capable of acquiring megavoltage computed-tomography images and registering them to the planning kVCT images for accurate target localization. Quality assurance (QA) of this device is time intensive, but can be expedited by improved QA tools and procedures. A custom- designed phantom was fabricated to improve the efficiency of daily QA of our Tomotherapy machine. The phantom incorporates ionization chamber measurement points, plugs of different densities and slide-out film cartridges. The QA procedure was designed to verify in less than 30 min the vital components of the tomotherapy system: static beam quality and output, image quality, correctness of image registration and energy of the helical dose delivery. Machine output, percent depth dose and off-axis factors are simultaneously evaluated using a static 5 x 40 cm(2) open field. A single phantom scan is used to evaluate image quality and registration accuracy. The phantom can also be used for patient plan-specific QA. The QA results over a period of 6 months are reported in this paper. The QA process was found to be simple, efficient and capable of simultaneously verifying several important parameters.
引用
收藏
页码:5663 / 5674
页数:12
相关论文
共 33 条
  • [1] Enhanced efficacy in helical tomotherapy quality assurance
    Goddu, S.
    Mutic, S.
    Chaudhari, S.
    Grigsby, J.
    Low, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2248 - 2248
  • [2] Helical Tomotherapy Patient Specific Quality Assurance in An Anthropomorphic Phantom
    Neeley, M.
    Harris, C.
    Charara, Y.
    Ramsey, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] TomoTherapy MVCT Quality Assurance Using the CatPhan Phantom
    Sutlief, S.
    Pattaserial, J.
    West, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E227 - E227
  • [4] Helical tomotherapy quality assurance using sinogram analysis
    Mahan, S
    Ramsey, C
    Chase, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1832 - 1832
  • [5] FILMLESS QUALITY ASSURANCE FOR HELICAL TOMOTHERAPY WITH A CYLINDRICAL STAIR-LIKE ALUMINIUM PHANTOM
    Althof, V.
    Kramer, D.
    Westendorp, R.
    van Haaren, P.
    Wispelweij, M.
    Minken, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S92 - S93
  • [6] A quality assurance tool for helical tomotherapy using a step-wedge phantom and the on-board MVCT detector
    Althof, Vincent
    van Haaren, Paul
    Westendorp, Rik
    Nuver, Tonnis
    Kramer, Dinant
    Ikink, Marijke
    Bel, Arjen
    Minken, Andre
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (01): : 148 - 163
  • [7] Independent point dose verification using TomoTherapy quality assurance phantom
    Cheek, D.
    Hogstrom, K.
    Robertson, C.
    Rosen, I.
    Gibbons, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2461 - 2461
  • [8] Quality Assurance for Total Marrow Irradiation (TMI) Using Helical Tomotherapy
    Zhang, X.
    Penagaricano, J.
    Yan, Y.
    Hancock, S.
    Ratanatharathorn, V.
    Corry, P.
    Moros, E.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [9] Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass
    Wong, J. H. D.
    Hardcastle, N.
    Tome, W. A.
    Bayliss, A.
    Tolakanahalli, R.
    Lerch, M. L. F.
    Petasecca, M.
    Carolan, M.
    Metcalfe, P.
    Rosenfeld, A. B.
    MEDICAL PHYSICS, 2011, 38 (04) : 2256 - 2264
  • [10] Beam Hardening Correction Using a Conical Water-Equivalent Phantom for Preclinical Micro-CT
    Deng, Junjun
    Yan, Shikui
    Chen, Mu
    Bruckbauer, Thomas
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2922 - 2924