Repeatability and Reproducibility of in-vivo Brain Temperature Measurements

被引:17
|
作者
Sharma, Ayushe A. [1 ,2 ,3 ]
Nenert, Rodolphe [3 ,4 ]
Mueller, Christina [1 ]
Maudsley, Andrew A. [5 ]
Younger, Jarred W. [1 ]
Szaflarski, Jerzy P. [2 ,3 ,4 ,6 ]
机构
[1] Univ Alabama Birmingham UAB, Dept Psychol, Birmingham, AL 35294 USA
[2] Univ Alabama Birmingham UAB, Dept Neurobiol, Birmingham, AL 35294 USA
[3] Univ Alabama Birmingham Epilepsy Ctr UABEC, Birmingham, AL 35294 USA
[4] Univ Alabama Birmingham UAB, Dept Neurol, Birmingham, AL USA
[5] Univ Miami, Miller Sch Med, Dept Radiol, Miami, FL 33136 USA
[6] Univ Alabama Birmingham UAB, Dept Neurosurg, Birmingham, AL USA
来源
关键词
MRS; brain temperature; MR thermometry; neuroinflammation; neuroimaging; MICROGLIAL ACTIVATION; LOBE EPILEPSY; INFLAMMATION; INJURY; HYPERTHERMIA; SPECTROSCOPY; RELIABILITY; METABOLITES; ADULTS; BODY;
D O I
10.3389/fnhum.2020.598435
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Magnetic resonance spectroscopic imaging (MRSI) is a neuroimaging technique that may be useful for non-invasive mapping of brain temperature (i.e., thermometry) over a large brain volume. To date, intra-subject reproducibility of MRSI-based brain temperature (MRSI-t) has not been investigated. The objective of this repeated measures MRSI-t study was to establish intra-subject reproducibility and repeatability of brain temperature, as well as typical brain temperature range. Methods: Healthy participants aged 23-46 years (N = 18; 7 females) were scanned at two time points similar to 12-weeks apart. Volumetric MRSI data were processed by reconstructing metabolite and water images using parametric spectral analysis. Brain temperature was derived using the frequency difference between water and creatine (T-CRE) for 47 regions of interest (ROIs) delineated by the modified Automated Anatomical Labeling (AAL) atlas. Reproducibility was measured using the coefficient of variation for repeated measures (COVrep), and repeatability was determined using the standard error of measurement (SEM). For each region, the upper and lower bounds of Minimal Detectable Change (MDC) were established to characterize the typical range of T-CRE values. Results: The mean global brain temperature over all subjects was 37.2 degrees C with spatial variations across ROIs. There was a significant main effect for time [F-(1,F- 1,F-591) = 37.0, p < 0.0001] and for brain region [F-(46,F- 1,F-591) = 2.66, p < 0.0001]. The time*brain region interaction was not significant [F-(46,F- 1,F-591) = 0.80, p = 0.83]. Participants' T-CRE was stable for each ROI across both time points, with ROIs' COVrep ranging from 0.81 to 3.08% (mean COVrep = 1.92%); majority of ROIs had a COVrep Conclusions: Brain temperature measurements were highly consistent between both time points, indicating high reproducibility and repeatability of MRSI-t. MRSI-t may be a promising diagnostic, prognostic, and therapeutic tool for non-invasively monitoring brain temperature changes in health and disease. However, further studies of healthy participants with larger sample size(s) and numerous repeated acquisitions are imperative for establishing a reference range of typical brain T-CRE, as well as the threshold above which T-CRE is likely pathological.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] REPEATABILITY AND REPRODUCIBILITY
    MANDEL, J
    MATERIALS RESEARCH AND STANDARDS, 1971, 11 (08): : 8 - &
  • [22] Repeatability and reproducibility of a hyperspectral imaging system for in vivo color evaluation
    Blaksley, Carl
    Udodaira, Kumiko
    Yoshida, Mie
    Nicolas, Alexandre
    Velleman, Damien
    Casolino, Marco
    Flament, Frederic
    SKIN RESEARCH AND TECHNOLOGY, 2022, 28 (04) : 544 - 555
  • [23] Reproducibility and Repeatability
    Slezak, P.
    Waczulikova, I.
    PHYSIOLOGICAL RESEARCH, 2011, 60 (01) : 203 - 204
  • [24] REPEATABILITY AND REPRODUCIBILITY
    SCOTT, CG
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1978, 1 (06): : R9 - R9
  • [25] Repeatability of In-Vivo Measurement of Lamina Cribrosa's Biomechanics
    Schwantes, Gabriela Cavagnoli
    Kamen, Leon
    Zambrano, Ronald
    Chung, Timothy K.
    Lee, Ting-Fang
    Danias, John
    Vande Geest, Jonathan
    Wollstein, Gadi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (09)
  • [26] In-vivo repeatability of three intra-oral spectrophotometers
    Hampe-Kautz, Vincent
    Roman, Tatiana
    Schwob, Thibault
    Cournault, Berangere
    Etienne, Olivier
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (03) : 520 - 526
  • [27] A proposed method to estimate the reproducibility and repeatability of measurements in a conglomerate of laboratories
    Pettersson, T
    Khorovskaya, L
    Kallner, A
    CLINICA CHIMICA ACTA, 2005, 355 : S370 - S370
  • [28] Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system
    Muscat, S
    Parks, S
    Kemp, E
    Keating, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (02) : 490 - 495
  • [29] Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography
    Muscat, S
    McKay, N
    Parks, S
    Kemp, E
    Keating, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (06) : 1791 - 1795
  • [30] Intraobserver repeatability and interobserver reproducibility in musculoskeletal ultrasound imaging measurements
    Balint, PV
    Sturrock, RD
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2001, 19 (01) : 89 - 92