Long-term aging studies on Resistive Plate Chambers (RPC) of the CMS muon system for HL-LHC

被引:0
|
作者
Gelmi, Andrea [1 ,2 ]
机构
[1] Ist Nazl Fis Nucl, Via Giovanni Amendola 173, IT-70125 Bari, Italy
[2] Univ Bari, Via Giovanni Amendola 173, IT-70125 Bari, Italy
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
During the phase II of the LHC physics program, called High Luminosity LHC (HL-LHC), the accelerator will increase the instantaneous luminosity up to 5x10(34)cm(-2) s(-1), providing to experiments an additional integrated luminosity of about 3000 fb(-1) over 10 years of operation, starting in 2026. The present Compact Muon Solenoid (CMS) Resistive Plate Chambers (RPC) system has been certified for 10 LHC years operation, at maximum background rate of 300 Hz/cm(2) and 50 mC/cm(2) as integrated charge. Based on Run2 data and assuming a liner dependence of the background rates as a function of the instantaneous luminosity, the expected rates and integrated charge at HL-LHC are about 600 Hz/cm(2) and 840 mC/cm(2), respectively (including a safety factor of three). HL-LHC will be threfore a challenge for the RPC system since the expected operating conditions are much higher with respect those for which the detectors have been designed, and could induce non-recoverable aging effects which can alter the detector properties. A new longevity test is then needed to estimate the impact of HL-LHC conditions up to an integrated charge equivalent to the integrated luminosity of 3000 fb, to confirm that the RPC system will survive to the harsher background conditions expected at HL-LHC. A dedicated consolidation program is ongoing at CERN Gamma Irradiation Facility (GIF++), where few RPC detectors are exposed to intense gamma radiation. The main detectors parameters (currents, rate, resistivity) are under monitoring as a function of the integrated charge and the performance studied with muon beam. After having collected a significant amount of the total irradiation preliminary results will be presented.
引用
收藏
页数:5
相关论文
共 33 条
  • [31] R &D of back-end electronics for improved resistive plate chambers for the phase 2 upgrade of the CMS end-cap muon system
    Kou, H.
    Liu, Z-A
    Zhao, J.
    Song, J.
    Hou, Q.
    Diao, W.
    Cao, P.
    Gong, W.
    Wang, N.
    Samalan, A.
    Tytgat, M.
    El Sawy, M.
    Alves, G. A.
    Marujo, F.
    Coelho, E. A.
    Da Silva De Araujo, F. Torres
    Da Costa, E. M.
    Nogima, H.
    Santoro, A.
    De Souza, S. Fonseca
    Damiao, D. De Jesus
    Thiel, M.
    Ferreira Filho, M. Barroso
    Amarilo, K. Mota
    Aleksandrov, A.
    Hadjiiska, R.
    Iaydjiev, P.
    Rodozov, M.
    Shopova, M.
    Sultanov, G.
    Dimitrov, A.
    Litov, L.
    Pavlov, B.
    Petkov, P.
    Petrov, A.
    Shumka, E.
    Qian, S. J.
    Avila, C.
    Barbosa, D.
    Cabrera, A.
    Florez, A.
    Fraga, J.
    Reyes, J.
    Assran, Y.
    Mahmoud, M. A.
    Mohammed, Y.
    Laktineh, I
    Grenier, G.
    Gouzevitch, M.
    Mirabito, L.
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2022, 6 (03) : 306 - 316
  • [32] Long Term Validation of the Optimal Filters Configuration for the Resistive Plate Chambers Gas System at the Large Hadron Collider Experiments
    Capeans, M.
    Guida, R.
    Hahn, F.
    Haider, S.
    Mandeli, B.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1775 - 1782
  • [33] Atlas Monitored Drift Tube long-term stability and aging study performed for the first time with the gas-recirculation system planned for LHC
    Zimmermann, S
    Cernoch, C
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3714 - 3718