Note: Model-based identification method of a cable-driven wearable device for arm rehabilitation

被引:9
|
作者
Cui, Xiang [1 ]
Chen, Weihai [1 ]
Zhang, Jianbin [2 ]
Wang, Jianhua [1 ]
机构
[1] Beihang Univ, Sch Automat Sci & Elect Engn, Beijing 100191, Peoples R China
[2] Beihang Univ, Sch Mech Engn & Automat, Beijing 100191, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2015年 / 86卷 / 09期
关键词
D O I
10.1063/1.4931577
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cable-driven exoskeletons have used active cables to actuate the system and are worn on subjects to provide motion assistance. However, this kind of wearable devices usually contains uncertain kinematic parameters. In this paper, a model-based identification method has been proposed for a cable-driven arm exoskeleton to estimate its uncertainties. The identification method is based on the linearized error model derived from the kinematics of the exoskeleton. Experiment has been conducted to demonstrate the feasibility of the proposed model-based method in practical application. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Tension reduction method for a modular cable-driven robotic arm with co-shared cables
    Wang, Yi
    Yang, Guilin
    Zheng, Tianjiang
    Shen, Wenjun
    Fang, Zaojun
    Zhang, Chi
    INTELLIGENT SERVICE ROBOTICS, 2022, 15 (01) : 27 - 38
  • [32] Tension reduction method for a modular cable-driven robotic arm with co-shared cables
    Yi Wang
    Guilin Yang
    Tianjiang Zheng
    Wenjun Shen
    Zaojun Fang
    Chi Zhang
    Intelligent Service Robotics, 2022, 15 : 27 - 38
  • [33] An Integrated Two-Level Self-Calibration Method for a Cable-Driven Humanoid Arm
    Chen, Quanzhu
    Chen, Weihai
    Yang, Guilin
    Liu, Rong
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2013, 10 (02) : 380 - 391
  • [34] Design of a Cable-Driven Interactive Rehabilitation Device with 3D Trajectory Tracking and Force Feedback
    Xu, Han
    Li, Yibin
    Xu, Dong
    Li, Xiaolong
    Fu, Jianming
    Zhang, Xu
    INTELLIGENT ROBOTICS AND APPLICATIONS (ICIRA 2022), PT I, 2022, 13455 : 759 - 768
  • [35] Nonlinear Disturbance Observer Based Sliding Mode Control of a Cable-driven Rehabilitation Robot
    Niu, Jie
    Yang, Qianqian
    Chen, Guangtao
    Song, Rong
    2017 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2017, : 664 - 669
  • [36] A Motion Decoupling Method for Cable-driven Joint Based on Movement Compensation
    He L.
    Chen J.
    Wu T.
    Yang L.
    Jiqiren/Robot, 2022, 44 (02): : 195 - 202
  • [37] A new hand rehabilitation system based on the cable-driven mechanism and dielectric elastomer actuator
    Amin, Heba
    Assal, Samy F. M.
    Iwata, Hiroyasu
    MECHANICAL SCIENCES, 2020, 11 (02) : 357 - 369
  • [38] Sensitivity Based Selection of an Optimal Cable-Driven Parallel Robot Design for Rehabilitation Purposes
    Ennaiem, Ferdaws
    Chaker, Abdelbadia
    Arevalo, Juan Sebastian Sandoval
    Laribi, Med Amine
    Bennour, Sami
    Mlika, Abdelfattah
    Romdhane, Lotfi
    Zeghloul, Said
    ROBOTICS, 2021, 10 (01) : 1 - 16
  • [39] Workspace analysis of cable-driven continuum manipulators based on static model
    Yuan, Han
    Li, Zheng
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2018, 49 : 240 - 252
  • [40] Design of a wearable cable-driven upper limb exoskeleton based on epicyclic gear trains structure
    Xiao, Feiyun
    Gao, Yongsheng
    Wang, Yong
    Zhu, Yanhe
    Zhao, Jie
    TECHNOLOGY AND HEALTH CARE, 2017, 25 : S3 - S11