Close to midgap trapping level in 60Co gamma irradiated silicon detectors

被引:50
|
作者
Pintilie, I
Fretwurst, E
Lindström, G
Stahl, J
机构
[1] Natl Inst Mat Phys, Bucharest, Romania
[2] Univ Hamburg, Inst Expt Phys, D-22761 Hamburg, Germany
关键词
D O I
10.1063/1.1490397
中图分类号
O59 [应用物理学];
学科分类号
摘要
The deep level transient spectroscopy method was applied on standard and oxygenated float-zone silicon detectors exposed to high doses of Co-60-gamma irradiation. We have detected and characterized a close to midgap trapping level having an ionization energy of E-C-(0.545+/-0.005) eV and electron/hole capture cross sections of sigma(n)=(1.7+/-0.2)x10(-15) cm(2)/sigma(p)=(9+/-1)x10(-14) cm(2) respectively. This level has a strong impact on the detector performance being responsible for more than 90% of the change in the effective doping concentration. The defect is strongly oxygen related and a possible connection with the V2O complex is discussed. (C) 2002 American Institute of Physics.
引用
收藏
页码:165 / 167
页数:3
相关论文
共 50 条
  • [11] Absolute 60Co characterization based on gamma-gamma coincident detection by two NaI(Tl) detectors
    Volkovitsky, Peter
    Naudus, Philip
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (03): : 568 - 572
  • [12] Low level measurement of 60Co by gamma ray spectrometry using γ-γ coincidence
    Paradis, H.
    Ott, A. de Vismes
    Luo, M.
    Cagnat, X.
    Piquemal, F.
    Gurriaran, R.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 487 - 492
  • [13] Comparison of two methods of therapy level calibration at 60Co gamma beams
    Bjerke, H
    Jarvinen, H
    Grimbergen, TWM
    Grindborg, JE
    Chauvenet, B
    Czap, L
    Ennow, K
    Moretti, C
    Rocha, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10): : 2729 - 2740
  • [14] STUDY OF IRRADIATED BOTHROPSTOXIN-1 WITH 60Co GAMMA RAYS: IMMUNE SYSTEM BEHAVIOR
    Caproni, P.
    Baptista, J. A.
    de Almeida, T. L.
    Passos, L. A. C.
    Nascimento, N.
    JOURNAL OF VENOMOUS ANIMALS AND TOXINS INCLUDING TROPICAL DISEASES, 2009, 15 (02): : 216 - 225
  • [15] Study of bulk damage in high resistivity silicon detectors irradiated by high dose of Co-60 gamma-radiation
    Li, Z
    Li, CJ
    Verbitskaya, E
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 251 - 255
  • [16] Study of bulk damage in high resistivity silicon detectors irradiated by high dose of Co-60 gamma-radiation
    Li, Z
    Li, CJ
    Verbitskaya, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 834 - 839
  • [17] Effects of 60Co gamma radiation on crotamine
    Boni-Mitake, M
    Costa, H
    Spencer, PJ
    Vassilieff, VS
    Rogero, JR
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2001, 34 (12) : 1531 - 1538
  • [18] ELASTIC SCATTERING OF 60CO GAMMA RAYS
    WEBER, B
    TRAIL, CC
    SAYRES, AR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (04): : 579 - &
  • [19] Features of tensoresistance depending on the crystallographic orientation of γ-irradiated (60Co) germanium and silicon single crystals
    Gaidar, G. P.
    Baranskii, P. I.
    PHYSICA B-CONDENSED MATTER, 2017, 512 : 6 - 11
  • [20] Study of 60Co as gamma source in backscatter gamma densitometers
    Peyvandi, R. Gholipour
    Rad, S. Z. Islami
    Taheri, A.
    Tootkaleh, S. Rahmanzadeh
    Lehdarboni, M. Askari
    KERNTECHNIK, 2015, 80 (03) : 275 - 279