Is There a Benefit to Modularity in 'Simpler' Femoral Revisions?

被引:31
|
作者
Huddleston, James I., III [1 ,4 ]
Tetreault, Matthew W. [2 ]
Yu, Michael [1 ]
Bedair, Hany [3 ]
Hansen, Viktor J. [3 ]
Choi, Ho-Rim [3 ]
Goodman, Stuart B. [1 ]
Sporer, Scott M. [2 ]
Della Valle, Craig J. [2 ]
机构
[1] Stanford Univ, Sch Med, Dept Orthopaed Surg, Stanford, CA 94305 USA
[2] Rush Univ, Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
[3] Massachusetts Gen Hosp, Dept Orthopaed Surg, Harris Orthoped Lab, Boston, MA 02114 USA
[4] Stanford Med Outpatient Ctr, Dept Orthopaed Surg, Redwood City, CA 94063 USA
关键词
TOTAL HIP-ARTHROPLASTY; POROUS-COATED STEMS; FOLLOW-UP; KNEE ARTHROPLASTY; BONE INGROWTH; COMPONENTS;
D O I
10.1007/s11999-015-4474-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Modular revision femoral components allow the surgeon to make more precise intraoperative adjustments in anteversion and sizing, which may afford lower dislocation rates and improved osseointegration, but may not offer distinct advantages when compared with less expensive monoblock revision stems. We compared modular and monoblock femoral components for revision of Paprosky Type I to IIIA femoral defects to determine (1) survivorship of the stems; and (2) complications denoted as intraoperative fracture, dislocation, or failure of osseointegration. Between 2004 and 2010, participating surgeons at three centers revised 416 total hip arthroplasties (THAs) with Paprosky Type I to IIIA femoral defects. Of those with minimum 2-year followup (343 THAs, mean followup 51 +/- 13 months), 150 (44%) were treated with modular stems and 193 (56%) were treated with monoblock, cylindrical, fully porous-coated stems. During this time, modular stems were generally chosen when there was remodeling of the proximal femur into retroversion and/or larger canal diameters (usually > 18 mm). A total of 27 patients died (6%) with stems intact before 2 years, 46 THAs (13%) were lost to followup before 2 years for reasons other than death, and there was no differential loss to followup between the study groups. The modular stems included 101 with a cylindrical distal geometry (67%) and 49 with a tapered geometry (33%). Mean age (64 versus 68 years), percentage of women (53% versus 47%), and body mass index (31 versus 30 kg/m(2)) were not different between the two cohorts, whereas there was trend toward a slightly greater case complexity in the modular group (55% versus 65% Type 3a femoral defects, p = 0.06). Kaplan-Meier survivorship was calculated for the endpoint of aseptic revision. Proportions of complications in each cohort (dislocation, intraoperative fracture, and failure of osseointegration) were compared. Femoral component rerevision for any reason (including infection) was greater (OR, 2.01; 95% CI, 1.63-2.57; p = 0.03) in the monoblock group (27 of 193 [14%]) compared with the modular cohort (10 of 150 [7%]). Femoral component survival free from aseptic rerevision was greater in the modular group with 91% survival (95% CI, 89%-95%) at 9 years compared with 86% survival (95% CI, 83%-88%) for the monoblock group in the same timeframe. There was no difference in the proportion of mechanically relevant aseptic complications (30 of 193 [16%] in the monoblock group versus 34 of 150 [23%] in the modular group, p = 0.10; OR, 1.47; 95% CI, 0.86-2.53). There were more intraoperative fractures in the modular group (17 of 150 [11%] versus nine of 193 [5%]; OR, 2.2; 95% CI, 1.68-2.73; p = 0.02). There were no differences in the proportions of dislocation (13 of 193 [7%] monoblock versus 14 of 150 [9%] modular; OR, 0.96; 95% CI, 0.67-1.16; p = 0.48) or failure of osseointegration (eight of 193 [4%] monoblock versus three of 150 [2%] modular; OR, 1.92; 95% CI, 0.88-2.84; p = 0.19) between the two groups with the number of hips available for study. Although rerevisions were less common in patients treated with modular stems, aseptic complications such as intraoperative fractures were more common in that group, and the sample was too small to evaluate corrosion-related or fatigue concerns associated with modularity. We cannot therefore conclude from this that one design is superior to the other. Larger studies and pooled analyses will need to be performed to answer this question, but we believe modularity should be avoided in more straightforward cases if possible. Level III, therapeutic study.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 50 条
  • [21] Revisions Rates of Surgical Treatment for Femoral Neck Fractures in Dialysis Patients
    Huang, Kevin
    Ewing, Brett A.
    Lin, Carol A.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2023, 237 (05) : S333 - S334
  • [22] A Comparison of Modular Tapered Versus Modular Cylindrical Stems for Complex Femoral Revisions
    Bedair, Hany
    Tetrault, Matthew
    Choi, Ho-Rim
    Mayle, Robert
    Bashyal, Ravi
    Abbot, Daniel
    Eberhardt, Jamie
    Sporer, Scott
    Della Valle, Craig
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 71 - 73
  • [23] A SIMPLER SURGICAL TECHNIQUE TO TREAT ASEPTIC NONUNION-ASSOCIATED FEMORAL LENGTH DISCREPANCY
    WU, CC
    SHIH, CH
    LEE, ZL
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1992, 111 (03) : 160 - 164
  • [24] Impaction technique and graft treatment in revisions of the femoral component -: Laboratory studies and clinical validation
    Höstner, J
    Hultmark, P
    Kärrholm, J
    Malchau, H
    Tveit, M
    JOURNAL OF ARTHROPLASTY, 2001, 16 (01): : 76 - 82
  • [25] Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
    Glen A. Turley
    Damian R. Griffin
    Mark A. Williams
    Medical & Biological Engineering & Computing, 2014, 52 : 685 - 694
  • [26] Fatigue behavior of a titanium femoral hip prosthesis with proximal sleeve-stem modularity
    Krygier, Jan Janusz, 1600, John Wiley & Sons Inc, New York, NY, United States (05):
  • [27] Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty
    Turley, Glen A.
    Griffin, Damian R.
    Williams, Mark A.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (08) : 685 - 694
  • [28] Modularity is unnecessary in primary femoral THA but has some advantages in primary acetabular THA - Response
    Harris, WH
    JOURNAL OF ARTHROPLASTY, 1996, 11 (03): : 337 - 338
  • [29] FATIGUE BEHAVIOR OF A TITANIUM FEMORAL HIP-PROSTHESIS WITH PROXIMAL SLEEVE-STEM MODULARITY
    KRYGIER, JJ
    DUJOVNE, AR
    BOBYN, JD
    JOURNAL OF APPLIED BIOMATERIALS, 1994, 5 (03) : 195 - 201
  • [30] Polyethylene wear in cases using femoral stems of similar geometry, but different metals, porous layer, and modularity
    Bal, BS
    Vandelune, D
    Gurba, DM
    Jasty, M
    Harris, WH
    JOURNAL OF ARTHROPLASTY, 1998, 13 (05): : 492 - 499