Comparison of locked plating and intramedullary nailing for periprosthetic supracondylar femur fractures after knee arthroplasty

被引:0
|
作者
Kilicoglu, Onder I. [1 ]
Akgul, Turgut [1 ]
Saglam, Yavuz [1 ]
Yazicioglu, Onder [1 ]
机构
[1] Istanbul Fac Med, Dept Orthopaed Surg, Istanbul, Turkey
来源
ACTA ORTHOPAEDICA BELGICA | 2013年 / 79卷 / 04期
关键词
knee arthroplasty; periprosthetic femur fracture; locked plate; intramedullary nailing; INVASIVE STABILIZATION SYSTEM; FEMORAL FRACTURES; FIXATION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study aimed to compare the efficacy of two treatment modalities for periprosthetic supracondylar fractures. The results of intramedullary nailing in 7 patients and locked plating in 9 patients were reviewed retrospectively. Mean follow-up was 4.3 years (range : 1 to 13 years). One patient died on the first postoperative day. Union of the fracture was achieved in the other 15 patients, after a mean time of 3.86 months : 3.9 months (range : 3 to 6 months) in the locked plate group and 3.86 months (range : 3 to 5 months) in the intramedullary nail group (p = 0.96). Mean Knee Society Score was 78 points (range : 68 to 84 points) and mean total knee range of motion was 82 degrees (range 70 degrees to 90 degrees) with no significant differences between groups. Sagittal and coronal plane measurements were similar both in the early postoperative period and at the last follow-up. The two treatment modalities had similar results with a high success rate.
引用
收藏
页码:417 / 421
页数:5
相关论文
共 50 条
  • [31] Distal Femoral Arthroplasty for Management of Periprosthetic Supracondylar Fractures of the Femur
    Rahman, Wael A.
    Vial, Tomas A.
    Backstein, David J.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (03): : 676 - 679
  • [32] Intramedullary nailing of periprosthetic femoral fractures after revision for total knee endoprosthesis
    Meyer, C.
    Alt, V.
    Heiss, C.
    Kraus, R.
    Szalay, G.
    Schnettler, R.
    UNFALLCHIRURG, 2011, 114 (03): : 241 - 247
  • [33] INTERLOCKING INTRAMEDULLARY NAILING FOR SUPRACONDYLAR AND INTERCONDYLAR FRACTURES OF THE DISTAL PART OF THE FEMUR
    LEUNG, KS
    SHEN, WY
    SO, WS
    MUI, LT
    GROSSE, A
    SHATIN, NT
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (03): : 332 - 340
  • [34] Supracondylar periprosthetic femoral fractures following total knee arthroplasty: treatment with a retrograde intramedullary nail
    K. Chettiar
    M. P. Jackson
    J. Brewin
    D. Dass
    P. A. Butler-Manuel
    International Orthopaedics, 2009, 33
  • [35] Locked plate versus retrograde intramedullary nail for periprosthetic femur fractures above total knee arthroplasty: a meta-analysis
    Bo Li
    Peng Gao
    Guixing Qiu
    Tao Li
    International Orthopaedics, 2016, 40 : 1689 - 1695
  • [36] Locked plate versus retrograde intramedullary nail for periprosthetic femur fractures above total knee arthroplasty: a meta-analysis
    Li, Bo
    Gao, Peng
    Qiu, Guixing
    Li, Tao
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (08) : 1689 - 1695
  • [37] Retrograde locked intramedullary nailing for aseptic supracondylar femoral nonunion following failed locked plating
    Wu, Chi-Chuan
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02): : 155 - 159
  • [38] Periprosthetic supracondylar femoral fractures above total knee arthroplasty: comparison of the locking and non-locking plating methods
    Bae, Dae Kyung
    Song, Sang Jun
    Yoon, Kyoung Ho
    Kim, Tae Yong
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (11) : 2690 - 2697
  • [39] Retrograde locked intramedullary nailing for aseptic supracondylar femoral nonunion following failed locked plating
    Gogna, Paritosh
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (03) : 406 - 406
  • [40] Periprosthetic supracondylar femoral fractures above total knee arthroplasty: comparison of the locking and non-locking plating methods
    Dae Kyung Bae
    Sang Jun Song
    Kyoung Ho Yoon
    Tae Yong Kim
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2690 - 2697