Transthoracic impedance study with large self-adhesive electrodes in two conventional positions for defibrillation

被引:19
|
作者
Krasteva, Vessela [1 ]
Matveev, Mikhail [1 ]
Mudrov, Nikolay [1 ]
Prokopova, Rada [1 ]
机构
[1] Bulgarian Acad Sci, Ctr Biomed Engn, BU-1113 Sofia, Bulgaria
关键词
transthoracic electrical impedance; defibrillation; PAD electrodes; low-amplitude high-frequency current; pre-shock measurement;
D O I
10.1088/0967-3334/27/10/007
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
External defibrillation requires the application of high voltage electrical impulses via large external electrodes, placed on selected locations on the thorax surface. The position of the electrodes is one of the major determinants of the transthoracic impedance ( TTI) which influences the intracardiac current flow during electric shock and defibrillation success. The variety of factors which influence TTI measurements raised our interest to investigate the range of TTI values and the temporal TTI variance during long-term application of defibrillation self-adhesive electrodes in two conventional positions on the patient's chest - position 1 ( sub-clavicular/sub-axillar position) and position 2 ( antero-posterior position). The prospective study included 86 randomly selected volunteers ( 39 male and 49 female, 67 patients with normal skin, 13 patients with dry skin and 6 patients with greasy skin, 16 patients with chest pilosity and 70 patients without chest pilosity). The TTI was measured according to the interelectrode voltage drop obtained by passage of a low-amplitude high-frequency current ( 32 kHz) between the two self-adhesive electrodes ( active area about 92 cm(2)). For each patient, the TTI values were measured within 10 s, 1 min and 5 min after sticking the electrodes to the skin surface, independently for the two tested electrode positions. We found that the expected TTI range is between 58 Omega and 152 Omega for position 1 and between 55 Omega and 149 Omega for position 2. Although the two TTI ranges are comparable, we measured significantly higher TTI mean of about ( 107.2 +/- 22.3) Omega for position 1 compared to ( 96.6 +/- 19.2) Omega for position 2 ( p= 0.001). This fact suggested that the antero-posterior position of the electrodes is favourable for defibrillation. Within the investigated time interval of 5 min, we observed a significant TTI reduction with about 6.9% ( 7.4 Omega/ 107.2 Omega) for position 1 and about 5.3% ( 5.1 Omega/ 96.6 Omega) for position 2. We suppose that the long-term application of self-adhesive electrodes would lead to improvement of the physical conditions for conduction of the defibrillation current and to diminution of energy loss in the electrode - skin contact impedance. We found that gender is important when position 1 is used because women have significantly higher TTI ( 111 +/- 20.3) Omega compared to the TTI of men ( 102.6 +/- 24) Omega ( p = 0.0442). Although we found some specifics of the electrode - skin contact layer, we can conclude that because of the insignificant differences in TTI, the operator of the defibrillator paddles does not need to take into consideration the skin type and pilosity of the patients. Analysis of the correlations between TTI and the individual patient characteristics ( chest size, weight, height, age) showed that these patient characteristics are unreliable factors for prediction of the TTI values and optimal defibrillation pulse parameters and energy.
引用
收藏
页码:1009 / 1022
页数:14
相关论文
共 50 条
  • [41] Microleakage of Porcelain and Composite Machined Crowns Cemented with Self-Adhesive or Conventional Resin Cement
    Ghazy, Mohamed
    El-Mowafy, Omar
    Roperto, Renato
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (07): : 523 - 530
  • [42] Characterization of Contemporary Conventional, Bulk-fill, and Self-adhesive Resin Composite Materials
    David, C.
    Cuevas-Suarez, C. E.
    de Cardoso, G. C.
    Isolan, C. P.
    de Moraes, R. R.
    da Rosa, W. L. O.
    Munchow, E. A.
    da Silva, A. F.
    OPERATIVE DENTISTRY, 2022, 47 (04) : 392 - 402
  • [43] MICROTENSILE BOND STRENGTH OF NEW SELF-ADHESIVE LUTING AGENTS AND CONVENTIONAL MULTISTEP SYSTEMS
    Viotti, Ronaldo G.
    Kasaz, Alline
    Pena, Carlos E.
    Alexandre, Rodrigo S.
    Arrais, Cesar A.
    Reis, Andre F.
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (05): : 306 - 312
  • [44] Performance study on the flame retardant self-adhesive resin composites
    Wuyunqiqige
    ICCM 21: 21ST INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS (ICCM-21), 2017,
  • [45] A Study of the Field Test Method for the Adhesive Performance Evaluation of Self-Adhesive Waterproofing Sheets
    Park, Jeong-Hwa
    Oh, Kyu-Hwan
    Oh, Sang-Keun
    Seo, Hyun-Jae
    Kang, Boo-Sung
    APPLIED SCIENCES-BASEL, 2023, 13 (15):
  • [46] DEFIBRILLATION OF HIGH-RISK PATIENTS DURING CORONARY ANGIOGRAPHY USING SELF-ADHESIVE, PREAPPLIED ELECTRODE PADS
    WILSON, RF
    SIRNA, S
    WHITE, CW
    KERBER, RE
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (04): : 380 - 381
  • [47] A MULTIPURPOSE, SELF-ADHESIVE PATCH ELECTRODE CAPABLE OF EXTERNAL PACING, CARDIOVERSION DEFIBRILLATION, AND 12-LEAD ELECTROCARDIOGRAM
    WINDLE, JR
    EASLEY, AR
    STRATBUCKER, RA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01): : 235 - 241
  • [48] Long-term effect of chlorhexidine on the dentin microtensile bond strength of conventional and self-adhesive resin cements: A two-year in vitro study
    20141017417052
    Stape, T.H.S. (thiagohs@hotmail.com), 1600, Elsevier Ltd (50):
  • [49] Long-term effect of chlorhexidine on the dentin microtensile bond strength of conventional and self-adhesive resin cements: A two-year in vitro study
    Scarabello Stape, Thiago Henrique
    Menezes, Murilo de Sousa
    Baggio Aguiar, Flavio Henrique
    Quagliatto, Paulo Sergio
    Soares, Carlos Jose
    Marcondes Martins, Luis Roberto
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2014, 50 : 228 - 234
  • [50] Repeated application of self-adhesive transcutaneous electrical nerve stimulation electrodes: an assessment of skin microflora
    Cottell, Jennifer
    Edmondson, Alan S.
    Fitzgerald, Pauline
    Hartford, Trudy
    Johnson, Mark I.
    PHYSIOTHERAPY, 2011, 97 (03) : 267 - 270