INTER- AND INTRAFRACTION VARIABILITY IN LIVER POSITION IN NON-BREATH-HOLD STEREOTACTIC BODY RADIOTHERAPY

被引:113
|
作者
Case, Robert B. [1 ]
Sonke, Jan-Jakob [2 ]
Moseley, Douglas J. [1 ]
Kim, John [1 ]
Brock, Kristy K. [1 ]
Dawson, Laura A. [1 ]
机构
[1] Univ Toronto, Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
关键词
Image-guided radiotherapy; IGRT; Intrafraction reproducibility; kilovoltage cone-beam computed tomography; CBCT; CONE-BEAM CT; IMAGE-GUIDED RADIOTHERAPY; ACCELERATOR FOCAL UNIT; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; TUMOR POSITION; LUNG-CANCER; PHASE-I; LOCALIZATION; MOTION;
D O I
10.1016/j.ijrobp.2009.03.058
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The inter- and intrafraction variability of liver position was assessed in patients with liver cancer treated with kilovoltage cone-beam computed tomography (CBCT)-guided stereotactic body radiotherapy. Methods and Materials: A total of 314 CBCT scans obtained in the treatment position immediately before and after each fraction were evaluated from 29 patients undergoing six-fraction, non-breath-hold stereotactic body radiotherapy for muresectable liver cancer. Off-line, the CBCT scans were sorted into 10 bins, according to the phase of respiration. The liver position (relative to the vertebral bodies) was measured using rigid alignment of the exhale CBCT liver with the exhale planning CT liver, following the alignment of the vertebrae. The interfraction liver position change was measured by comparing the pretreatment CBCT scans, and the intrafraction change was measured from the CBCT scans obtained immediately before and after each fraction. Results: The mean amplitude of liver motion for all patients was 1.8 mm (range, 0.1-5.7), 8.0 mm (range, 0.1-18.8), and 4.3 mm (range 0.1-12.1) in the medial-lateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. The mean absolute ML, CC, and AP interfraction changes in liver position were 2.0 mm (90th percentile, 4.2), 3.5 mm (90th percentile, 7.3), and 2.3 mm (90th percentile, 4.7). The mean absolute intrafraction ML, CC, and AP changes were 1.3 mm (90th percentile, 2.9), 1.6 mm (90th percentile, 3.6), and 1.5 mm (90th percentile, 3.1), respectively. The interfraction changes were significantly larger than the intrafraction changes, with a CC systematic error of 2.9 and 1.1 mm, respectively. The intraobserver reproducibility (sigma, n = 29 fractions) was 1.3 rum in the ML, 1.4 mm in the CC, and 1.6 rum in the AP direction. Conclusion: Interfraction liver position changes relative to the vertebral bodies are an important source of geometric uncertainty, providing a rationale for prefraction soft-tissue image guidance. The intrafraction change in liver position from the beginning to the end of each fraction was small for most patients. (c) 2009 Elsevier Inc.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [11] Intrafraction cone beam computed tomography verification of breath hold during liver stereotactic radiation therapy
    Brown, Elizabeth
    Muscat, Erika
    O'Connor, Patrick
    Liu, Howard
    Lee, Yoo-Young
    Pryor, David
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2021, 68 (01) : 52 - 59
  • [12] Cone Beam CT image guidance strategies in non-breath hold stereotactic liver radiotherapy
    Case, R. B.
    Eccles, C. L.
    Moseley, D.
    Dinniwell, R.
    Kim, J.
    Bezjak, A.
    Dawson, L. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S147 - S147
  • [13] Phased array breath-hold versus non-breath-hold MR imaging of focal liver lesions: A prospective comparative study
    Yamashita, Y
    Yamamoto, H
    Namimoto, T
    Abe, Y
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02): : 292 - 297
  • [14] Intrafractional fiducial marker position variations in stereotactic liver radiotherapy during voluntary deep inspiration breath-hold
    Stick, Line Bjerregaard
    Vogelius, Ivan Richter
    Risum, Signe
    Josipovic, Mirjana
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1116):
  • [15] Dosimetric Impact of Deep Inspiration Breath Hold Uncertainty on Pancreas Stereotactic Body Radiotherapy
    Han-Oh, S.
    Hill, C.
    Wang, K. K. H.
    Ding, K.
    Li, H.
    Chen, H.
    Meyer, J. J.
    Narang, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E373 - E374
  • [16] Breath hold cone beam CT for image guided stereotactic radiotherapy for liver cancer
    Hawkins, MA
    Brock, K
    Eccles, C
    Moseley, D
    Jaffray, D
    Dawson, LA
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 : S80 - S80
  • [17] Characteristics of Tumor Motions with Deep Inspiration Breath Hold for Lung Stereotactic Body Radiotherapy Patients
    Zhao, G.
    Jayarathna, S. Y.
    Peeler, C. R.
    Pollard-Larkin, J. M.
    Sadagopan, R.
    Nitsch, P. L.
    Ohrt, J. D.
    Gao, S.
    Balter, P.
    Wang, X.
    MEDICAL PHYSICS, 2024, 51 (10) : 7861 - 7862
  • [18] Verification of Target Volume Margin of Visual-Guided Breath-Hold Method in Stereotactic Body Radiotherapy for Liver Cancer
    Cho, M.
    Kim, H.
    Yoon, S.
    Jung, J.
    Lee, S.
    Kwak, J.
    Yoon, K.
    Jeong, C.
    Park, M.
    Kim, H.
    Kim, S.
    Cho, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E335 - E335
  • [19] Hypofractionated image-guided breath-hold SABR (Stereotactic Ablative Body Radiotherapy) of liver metastases - clinical results
    Boda-Heggemann, Judit
    Dinter, Dietmar
    Weiss, Christel
    Frauenfeld, Anian
    Siebenlist, Kerstin
    Attenberger, Ulrike
    Ottstadt, Martine
    Schneider, Frank
    Hofheinz, Ralf-Dieter
    Wenz, Frederik
    Lohr, Frank
    RADIATION ONCOLOGY, 2012, 7
  • [20] Implementation of Feedback Guided Voluntary Breath Hold Gating for CBCT Based Stereotactic Body Radiotherapy
    Peng, Y.
    Vedam, S.
    Gao, S.
    Polf, J.
    Sadagopan, R.
    Balter, P.
    MEDICAL PHYSICS, 2009, 36 (06)