Accuracy and accommodation capability of a handheld autorefractor

被引:73
|
作者
Wesemann, W
Dick, B
机构
[1] Sch Optometry HFAK, Cologne, Germany
[2] Univ Mainz, Dept Ophthalmol, D-6500 Mainz, Germany
来源
关键词
D O I
10.1016/S0886-3350(99)00325-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the accuracy of measurement by the Nikon Retinomax handheld autorefractor and its ability to relax accommodation. Setting: Pediatric Section, Department of Ophthalmology, University of Mainz, Germany. Methods: To perform a series of comparative measurements, autorefractor readings were obtained on healthy young adults (students) and on children aged 2 to 12 years. The autorefractor readings were compared with subjective refractions of the young adults and with cycloplegic retinoscopy of the children. Results: In adults, the accuracy of the handheld autorefractor measurements was comparable to that of conventional tabletop autorefractors. In children, the autorefractor measurements performed under cycloplegia were reliable; when cycloplegic agents were not 2.0 diopters. Conclusion: Cycloplegia is often necessary to obtain accurate autorefractor results. J Cataract Refract Surg 70 (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:62 / 70
页数:9
相关论文
共 50 条
  • [41] Plusoptix Vision Screener: the accuracy and repeatability of refractive measurements using a new autorefractor
    Dahlmann-Noor, A. H.
    Comyn, O.
    Kostakis, V.
    Misra, A.
    Gupta, N.
    Heath, J.
    Brown, J.
    Iron, A.
    McGill, S.
    Vrotsou, K.
    Vivian, A. J.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (03) : 346 - 349
  • [42] Accuracy of a Smartphone-based Autorefractor Compared with Criterion-standard Refraction
    Jeganathan, V. Swetha E.
    Valikodath, Nita
    Niziol, Leslie M.
    Hansen, Sean
    Apostolou, Hannah
    Woodward, Maria A.
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (12) : 1135 - 1141
  • [43] Accuracy of Two Autorefractors - Pediatric Autorefractor plusoptiX and Retinomax - in Cycloplegic Children in Comparison to Retinoscopy
    Schmidt-Bacher, A. E.
    Kahlert, C.
    Kolling, G.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (10) : 792 - 797
  • [44] Research on New Energy Accommodation Capability of China in 2020
    Yuan, Bo
    Xu, Zhicheng
    Yang, Jie
    Zong, Jin
    2019 IEEE ASIA POWER AND ENERGY ENGINEERING CONFERENCE (APEEC 2019), 2019, : 313 - 316
  • [45] Entry deterrence/accommodation with imperfect strategic thinking capability
    Chen, Yuxin
    Turut, Ozge
    QME-QUANTITATIVE MARKETING AND ECONOMICS, 2018, 16 (02): : 175 - 207
  • [46] Total Supply Capability Curve and Total Accommodation Capability Curve of Active Distribution Network
    Xiao J.
    Wang C.
    Bao Z.
    She B.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (02): : 672 - 689
  • [47] Entry deterrence/accommodation with imperfect strategic thinking capability
    Yuxin Chen
    Ozge Turut
    Quantitative Marketing and Economics, 2018, 16 : 175 - 207
  • [48] Evaluation and Application of Accommodation Capability of Wind Power for Grid
    Cheng Xueting
    Ning Ke
    Hao Jie
    Li Yongxiang
    Hao Xinjie
    Zheng Huiping
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 6923 - 6927
  • [49] Clinical Accuracy and Precision of a Hand-Held Shack Hartman Wavefront Sensor Autorefractor
    Brown, Nicolas
    Vaz, Tara C.
    Pikul, Olga
    Dowd, Robert
    Nally, Rebecca L.
    Klein, Sarah B.
    Yoon, Geunyoung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [50] Evaluation of an open-field autorefractor's ability to measure refraction and hence potential to assess objective accommodation in pseudophakes
    Wolffsohn, James Stuart
    Davies, Leon Nicholas
    Naroo, Shehzad Anjam
    Buckhurst, Phillip Jonathan
    Gibson, George Anthony
    Gupta, Navneet
    Craig, Jennifer Patricia
    Shah, Sunil
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (04) : 498 - 501