Bioelectrical impedance in the clinical evaluation of liver disease

被引:0
|
作者
Schloerb, PR
Forster, J
Delcore, R
Kindscher, JD
机构
[1] UNIV KANSAS, MED CTR, DEPT ANESTHESIOL, LIVER TRANSPLANT PROGRAM, KANSAS CITY, KS 66160 USA
[2] UNIV KANSAS, MED CTR, NUTR SUPPORT SERV, KANSAS CITY, KS 66160 USA
来源
AMERICAN JOURNAL OF CLINICAL NUTRITION | 1996年 / 64卷 / 03期
关键词
bioelectrical impedance; total body water; liver; cirrhosis; ascites; body composition; bromide; extracellular water;
D O I
暂无
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Liver disease is often characterized by an accumulation of excess body water as ascites, edema, or both. It was our purpose, using bioelectrical impedance analysis (BIA), to measure total body water (TBW) and extracellular water (ECW) in 35 patients with end-stage Liver disease, including those undergoing orthotopic liver transplantation and, in 15 of these patients, to compare these values with measurements of TBW by deuterium oxide and of ECW by bromide dilutions. Poor correlation of TBW derived from BIA with TBW by deuterium dilution was found (r = 0.36, P = 0.35). In 19 patients, in whom TBW and ECW were not measured by dilution studies, 158 BIA measurements were taken for determining TBW. In 15 orthotopic liver transplantation patients with various amounts of fluid overload, a modest correlation was found between short-term weight change and BIA (r = 0.38, P = 0.001). In patients with fluid overload not exceeding 25% of ECW, ECW correlated with reactance (r = -0.96, P = 0.0025). TBW and ECW were covariant (r = 0.68, P = 0.01). In three patients with cirrhotic ascites, impedance measurements were taken with source electrodes on the hand and foot and detector electrodes on the abdomen during paracentesis of 8-11 L. Calculated volume of ascites correlated with measured volume (r = 0.99, P = 0.001). Segmental electrode placement and parallel impedance measurements were effective in determining ascites fluid volume.
引用
收藏
页码:510 / 514
页数:5
相关论文
共 50 条
  • [41] CLINICAL SIGNIFICANCE OF GUIDELINE NON-COMPLIANCE IN BIOELECTRICAL IMPEDANCE
    Haque, M.
    Joyce, D.
    Walsh, D.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 : S18 - S19
  • [42] Repeatability of Bioelectrical Impedance Spectroscopy in Preterm Infants for Clinical Use
    Kanazawa, Hoshinori
    Kawai, Masahiko
    Iwanaga, Kougorou
    Yamada, Yosuke
    Heike, Toshio
    INTERNATIONAL JOURNAL OF OBESITY, 2011, 35 : S60 - S60
  • [43] Assessing Pain Levels Using Bioelectrical Impedance in Low Back Pain Patients: Clinical Performance Evaluation
    Jang, Seungwan
    Ho, Jong Gab
    Jo, A-Ram
    Yoo, Seung Mo
    Lee, Hoonyoung
    Lee, Hyunyoung
    Kim, Young
    Min, Se Dong
    DIAGNOSTICS, 2024, 14 (21)
  • [44] Bioelectrical impedance and hemodialysis
    Mandolfo, S
    Farina, M
    Imbasciati, E
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1995, 18 (11): : 700 - 704
  • [45] BIOELECTRICAL IMPEDANCE TESTING
    WRIGHT, RE
    REBEL, A
    SOUTH AFRICAN MEDICAL JOURNAL, 1991, 79 (05): : 284 - 285
  • [46] Use of bioelectrical impedance analysis measurements in the clinical management of malnutrition
    Pencharz, PB
    Azcue, M
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 64 (03): : 485 - 488
  • [47] Bioelectrical phase angle and impedance vector analysis - Clinical relevance and applicability of impedance parameters
    Norman, Kristina
    Stobaus, Nicole
    Pirlich, Matthias
    Bosy-Westphal, Anja
    CLINICAL NUTRITION, 2012, 31 (06) : 854 - 861
  • [48] Bioelectrical Impedance Analysis
    Ward, L. C.
    Mueller, M. J.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 : S1 - S1
  • [49] BIOELECTRICAL IMPEDANCE OR ANTHROPOMETRY
    DEURENBERG, P
    VANDERKOOY, K
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1989, 43 (07) : 503 - 504
  • [50] Evaluation of bioelectrical impedance for prospective nutritional assessment in cystic fibrosis
    Quirk, PC
    Ward, LC
    Thomas, BJ
    Holt, TL
    Shepherd, RW
    Cornish, BH
    NUTRITION, 1997, 13 (05) : 412 - 416