X-ray diffuse scattering for evaluation of wide bandgap semiconductor nuclear radiation detectors

被引:8
|
作者
Goorsky, MS
Yoon, H
Schieber, M
James, RB
McGregor, DS
Natarajan, M
机构
[1] HEBREW UNIV JERUSALEM,GRAD SCH APPL SCI & TECHNOL,IL-91904 JERUSALEM,ISRAEL
[2] SANDIA NATL LABS,DEPT 8347,LIVERMORE,CA 94550
[3] TN TECHNOL,ROUND ROCK,TX 78680
关键词
D O I
10.1016/S0168-9002(96)00288-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The crystalline perfection of solid state radiation detectors was examined using triple axis x-ray diffraction. Triple axis techniques provide a means to analyze the origin of diffraction peak broadening: the effects of strain (due to deviations in alloy composition or stoichiometry) and lattice tilts (mosaic structure) can be separated. Cd1-xZnxTe (x approximate to 0.1), HgI2, and GaAs detector materials were studied. In the cases of Cd1-xZnxTe and HgI2 the crystalline properties of detectors with different spectral responses to gamma-radiation were determined. Increased mosaicity was universally found to be related to deteriorated detector properties. For Cd1-xZnxTe, detectors with poor performance possessed greater levels of diffuse scatter due to lattice tilts than did high quality detectors. For GaAs, low angle grain boundaries were attributed to impaired detector performance. Additionally, in large HgI2 detectors, deviations from stoichiometry were also related to reduced performance. Interestingly, HgI2 detectors which possessed a sharp spectral response to gamma-radiation but also showed polarization were of comparable crystallinity to those detectors which did not exhibit polarization effects. This initial analysis suggests that polarization is related to native point defects or chemical impurities which do not significantly alter the crystallinity of the material. Overall, within a given class of materials, improved detector performance (better spectral response) always correlated with better material quality.
引用
收藏
页码:6 / 9
页数:4
相关论文
共 50 条
  • [41] Measurement of Soft X-Ray Radiation using the PF-4 Plasma Focus Setup with Semiconductor X-Ray Detectors
    Eliseev, S. P.
    Nikulin, V. Ya.
    Silin, P. V.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2009, 36 (01) : 1 - 7
  • [42] Measurement of soft X-ray radiation using the PF-4 plasma focus setup with semiconductor X-ray detectors
    S. P. Eliseev
    V. Ya. Nikulin
    P. V. Silin
    Bulletin of the Lebedev Physics Institute, 2009, 36 : 1 - 7
  • [43] X-RAY DIFFUSE SCATTERING IN THE FERROELECTRIC MATERIALS
    Pietraszko, A.
    Lukaszewicz, K.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C229 - C229
  • [44] Bringing diffuse X-ray scattering into focus
    Wall, Michael E.
    Wolff, Alexander M.
    Fraser, James S.
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2018, 50 : 109 - 116
  • [45] X-RAY DIFFUSE SCATTERING BY PEROVSKITE CRYSTALS
    DENOYER, F
    COMES, R
    LAMBERT, M
    GUINIER, A
    ACTA CRYSTALLOGRAPHICA SECTION A, 1972, 28 : S178 - S178
  • [46] Variational approach to X-ray diffuse scattering
    Fanchenko, SS
    Nefedov, AA
    PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 1999, 212 (01): : R3 - R4
  • [47] ON X-RAY DIFFUSE SCATTERING BY MOLECULAR CRYSTALS
    TANAKA, S
    NAYA, S
    ODA, T
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1969, 27 (04) : 962 - &
  • [48] X-ray diffuse scattering multilayer nanostructures
    Andreev, AV
    Ponomarev, YV
    Platonov, YY
    Salashchenko, NN
    NONLINEAR OPTICS OF LOW-DIMENSIONAL STRUCTURES AND NEW MATERIALS - ICONO '95, 1996, 2801 : 75 - 87
  • [49] Variational approach to X-ray diffuse scattering
    Russ. Res. Ctr. Kurchatov Institute, Kurchatov Sq. 1, 123182, Moscow, Russia
    Phys. Status Solidi B Basic Res., 1 (R3-R4):
  • [50] Diffuse x-ray scattering in perovskite ferroelectrics
    Chapman, BD
    Stern, EA
    Han, SW
    Cross, JO
    Seidler, GT
    Gavrilyatchenko, V
    Vedrinskii, RV
    Kraizman, VL
    PHYSICAL REVIEW B, 2005, 71 (02)