A Novel Reference Current Generation Algorithm for Three Phase Shunt Active Power Filter

被引:2
|
作者
Joseph, Deepthi [1 ]
Kalaiarasi, N. [2 ]
Rajan, K. [3 ]
机构
[1] Vel Tech High Tech Dr Rangarajan Dr Sakunthala En, EEE Dept, Madras, Tamil Nadu, India
[2] RMK Coll Engn Technol, Madras, Tamil Nadu, India
[3] Vel Tech Engn Coll, Madras, Tamil Nadu, India
关键词
Discrete Fourier transform approach; Synchronous detection method; PLL; UDCS; Current extraction method;
D O I
10.1007/978-81-322-2119-7_143
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Reference current generation algorithms for shunt active power filters have always been associated with increased computational tasks. In this paper we present a method to reduce the computational task and thereby increase the processing speed of the filter. We suggest a new fundamental current extraction method which involves peak value calculation of the distorted signal. The method is achieving the same compensation level as that of the conventional method which has been verified by MATLAB/SIMULINK software.
引用
收藏
页码:1467 / 1475
页数:9
相关论文
共 50 条
  • [41] Novel method of calculating current reference for shunt active power filters
    Gong, Mao-Zhong
    Liu, Han-Kui
    Gu, Jian-Jun
    Xu, Dian-Guo
    2002, Chinese Society for Electrical Engineering (22):
  • [42] A novel current detection algorithm for shunt active power filters in harmonic elimination, reactive power compensation and three-phase balancing
    Li, HY
    Zhuo, F
    Wu, LH
    Lei, WJ
    Liu, JJ
    Wang, ZA
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 1017 - 1023
  • [43] Active power filter based on novel current reference calculation
    Gong, MZ
    Liu, HK
    Gu, JJ
    Xu, DG
    IEEE ICIT' 02: 2002 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 327 - 331
  • [44] Reference values for three-phase active power filter
    Stanciu, D.
    Florescu, A.
    Stoichescu, D. A.
    2008 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION, QUALITY AND TESTING, ROBOTICS (AQTR 2008), THETA 16TH EDITION, VOL III, PROCEEDINGS, 2008, : 200 - 203
  • [45] Current Control Based on Three-Phase Shunt Hybrid Active Power Filter Case Study
    Dai, Wenjin
    Li, Hongyun
    Chen, Ming
    2008 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-5, 2008, : 214 - 219
  • [46] Advanced Control Algorithm for Three-Phase Shunt Active Power Filter Using Sliding DFT
    Sozanski, Krzysztof
    Szczesniak, Pawel
    ENERGIES, 2023, 16 (03)
  • [47] Grid Harmonic Current Correction Based on Parallel Three-Phase Shunt Active Power Filter
    De souza, Laysa L.
    Rocha, Nady
    Fernandes, Darlan A.
    De Sousa, Reuben P. R.
    Jacobina, Cursino B.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (02) : 1422 - 1434
  • [48] Performance analysis and improvement of output current controller for three-phase shunt active power filter
    Wei, XueLiang
    Dai, Ke
    Fang, Xin
    Geng, Pan
    Kang, Yong
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 2615 - +
  • [49] Reference Current Estimation for Three-Phase Delta-Connected Active Power Filter
    Gao, Fanqiang
    Zhu, Haibin
    Li, Zixin
    Chu, Zunfang
    Wang, Ping
    Li, Yaohua
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) ASIA-PACIFIC 2014, 2014,
  • [50] The Research of Three-phase Three-wire Shunt Active Power Filter Current Loop Multiple control
    Wei, Xueliang
    Liang, Zhishan
    Meng, Xiangping
    Ji, Zhaqjun
    Cui, Lingzhi
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2039 - +